Contents Bore size (mm) CM2K20-PS CM2K25-PS CM2K32-PS CM2K40-PS 20 25 32 40 CM2K20-PS CM2K25-PS CM2K32-PS CM2K40-PS NBR Rod seal !8 Since the seal kit does not include a grease pack, order it separately.
Seal kit includes a grease pack (32 to 50 : 10 g, 63, 80 : 20 g, 100 : 30g). Order with the following part number when only the grease pack is needed. Grease pack part no. : GR-S-010 (10g), GR-S-020 (20g) 32
Seal kit includes a grease pack (32 to 50: 10 g, 63, 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) 31
Magnetically Coupled Rodless Cylinder/Direct Mount Type: Both Sides Piping Type Series CY3R 6, 10, 15, 20 25, 32, 40, 50 63 Replacement Procedure is P.316 Construction Both sides piping type Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
EX250 is a serial interface unit controlling up to 32 solenoids and 32 inputs. This serial interface is compatible with series SY, JSY, VQC, SV and S0700 valves. Available protocols include DeviceNet™, CC-Link, AS-i, PROFIBUS-DP®, and CANopen.
EX250 is a serial interface unit controlling up to 32 solenoids and 32 inputs. This serial interface is compatible with series SY, JSY, VQC, SV and S0700 valves. Available protocols include DeviceNet™, CC-Link, AS-i, and CANopen.
EX250 is a serial interface unit controlling up to 32 solenoids and 32 inputs. This serial interface is compatible with series SY, JSY, VQC, SV and S0700 valves. Available protocols include DeviceNet™, CC-Link, AS-i, and CANopen.
The SJ2000/3000 can be combined in the same manifold, which can provide up to 24 stations and 32 solenoids.
The SJ2000/3000 can be combined in the same manifold, which can provide up to 24 stations and 32 solenoids.
The SJ2000/3000 can be combined in the same manifold, which can provide up to 24 stations and 32 solenoids.
. -7No.EX-OMV0023-A
Model Indication and How to Order EX260-SPL 1 Connector type, output specification 1 M12 connector, 32 outputs, PNP (negative common) / source 3 M12 connector, 16 outputs, PNP (negative common) / source Fieldbus PL POWERLINK -8No.EX-OMV0023-A
Summary of Product elements
O N 1 2 3 4 5 6 7 8 9 10 F-Address 512 128 64 32 16 8 2 value 256 4 1 Fig. 10-7 PROFIsafe address switch Note: The F-Address bit numbering shown on the label has priority over any numbers printed on the DIP switch e.g. in the example above the DIP switch is printed with numbers 1 to 10 where 1 is on left and 10 is on the right.
(Parameter Default) 32 6. (Clear Error Log) 32 -27No.EX-OML0010CN-C 1. 1. Tag Input (23 ) -28No.EX-OML0010CN-C 2. EX600 (SI SW ) SI SW Re Register 2. Re Register PROFIBUS DPSI -29No.EX-OML0010CN-C 3. Hold/Clear Hold/Clear SI PLC Hold/Clear 3. Hold/Clear HandheldSwitch HandheldPLCHold/Clear SwitchSI Hold/Clear -30No.EX-OML0010CN-C 4. 4.
Symbol Data type Data length Bit [byte] Description (IO-Link standard) U8 8[1] UIntegerT Unsigned integer) U16 16[2] S16 IntegerT 16[2] Signed integer F32 Float32T 32[4] Floating point number 4: If the unit is not available when the unit is changed, a rejection response will be generated. In that case, change the range and unit to an available unit.
If the minimum setting unit is 2 L/min, the display will change in 2 L/min steps, e.g. 30..32..34 L/min. Smallest settable increment The flow which is converted to the volume at 20 oC and 101.3 kPa (absolute pressure).
[F 32] Selection of sub screen complete. You can select reversed output for OUT1 when freversed flow is detected (LLL is displayed). Only OUT1 can be selected. Hysteresis mode and window comparator mode can be selected as output mode. The output is reversed when the function ON is selected.
[F 2] OUT2 38 No.LFE*-OMY0008 c. / Add/dEC OUT1 (31 ) ( [n2AH]) ( [n2dH]) c.(32 ) 4. 4. 4. 4.
Indication Item Setting, selection and display Default setting ASCII code (1) Mode Communication format Binary data EIA RS-485 (2) Type Standard EIA RS-232C 9600bps (3) Baud Rate Communication speed 19200bps (4) Device Address Device address 1 to 32 Select from 1 to 32 1 Disabled (5) DIO Run/Stop *1 Run/stop by contact input Enabled Displays the communication status (6) Communication
Indication Item Setting, selection and display Default setting ASCII code (1) Protocol Communication format Binary data EIA RS-485 (2) Type Standard EIA RS-232C 9600 bps (3) Baud Rate Communication speed 19200 bps (4) Slave Address Slave address 1 to 32 Select from 1 to 32 1 Disabled (5) DIO Run/Stop 1 Run/stop by contact input Enabled Displays the communication status Communication status
In the latter case, up to 32 products can be connected. Both ends of the communication connection (the end nodes) need to be connected to the higher level computer.