Never mount the product in a place that will be used as a scaffold during piping.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Note 2) When mounting a cylinder with a stroke over 100mm, use the section A mounting threads.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
AD27-6-A With bowl guard AD27-6C-A AD37m-6-A AD47m-6-A Normally open (N.O.) With bowl guard AD38m-6-A AD48m-6-A Automatic (Auto drain) Manual With drain cock C2SF-2-A C3SF-2-A C4SF-2-A With level gauge C3LF-8-A C4LF-8-A With drain guide (without valve function) C2SFm-2J-A C3SFm-2J-A C4SFm-2J-A With level gauge C3LFm-8J-A C4LFm-8J-A Metal Normally closed (N.C.)
How to Replace One-touch Fittings How to Replace Silencers Warning A single body ported valve has a built-in silencer. A dirty and clogged silencer may reduce cylinder speed or cause a malfunction. Replace the silencer periodically. The cylinder port fittings are a cassette for easy replacement.
10(S)A 10 15.9 17.4 23 41.2 26.1 62.5 15.6 46 (46) AS33l1FG-02-12(S)A 12 18.5 42.5 28.3 64.7 17 48 (48) AS33l1FG-03-06(S)A 6 11.2 12.9 16.6 20.2 36 21.4 57.8 AK 1/4 19 50 48.4 44.5 42.9 VCHC 13.3 32 (33) AS33l1FG-03-08(S)A 8 13.2 37.1 23.5 52.2 14.2 33 (34) AS33l1FG-03-10(S)A 10 15.9 17.4 23 41.2 26.1 54.8 15.6 37 (38) AS33l1FG-03-12(S)A 12 18.5 42.5 28.3 57 17 38 (39) AS43l1FG-04-10(S)A
No operation program 37 Trying to execute a program/step with no commands. Invalid movement command 38 Trying to execute a command other than MOVA, MOVI, or ASET with a step (position movement) designated operation. Format error 39 An error is found in the attached value of a command being programmed. Refer to the Series LC1 instruction manual for alarm details.
(mm) At the minimum stroke of standard adjustment bolt At the minimum stroke of 25 mm adjustment bolt Basic stroke At maximum stroke adjustment Bore size (mm) Bore size (mm) 10 15 25 Adjustment bolt fixing bolts Tightening torque Adjustment width across flats 10 15 25 A 2 A 26 A = 0.8 A = 0.6 A 0 M3 1.0 to 1.3 Nm 4 A 2 A 26 M5 4.6 to 6.2 Nm 5 Adjuster holder A Adjuster holder Adjustment
Auto switch model Bore size [mm] 20 25 32 40 D-M9m(V) D-M9mW(V) BM8-020 (A set of a, b, c, d) BM8-025 (A set of a, b, c, d) BM8-032 (A set of a, b, c, d) BM8-040 (A set of a, b, c, d) BM8-025S (A set of a, b, c, d) * S: Stainless steel set screw BM8-032S (A set of a, b, c, d) * S: Stainless steel set screw BM8-040S (A set of a, b, c, d) * S: Stainless steel set screw D-M9mA(V) BM8-020S (A
Diaphragm B moves to the right, and at the same time diaphragm A also moves to the right pushing pilot valve A. 3. When pilot valve A is pushed, air acts upon the switching valve, drive chamber A switches to a supply state, and the air which was in drive chamber B is exhausted to the outside. 4. When air enters drive chamber A, diaphragm B moves to the left pushing pilot valve B. 5.
(Plug: M-5P) 49 46 38 5 22 12 19 4 40 25 Y Y 5.5 Operating port M5 ~0.8 24 84 Operation direction B (Plug: M-5P) Operation direction B A 7 6.5 13 10 10 13 A 14.8 30 7 24 A 15.8 Z Cross section AA (scale 50%) (N-1) x H G H 6 depth 4.5 5H9 +0.03 N-M4 x 0.7 thread depth 8 0 Bottom through hole 3.3 5H9 +0.03depth 4.5 0 F E Model J N H G F E Z MXW8-25 64 3 32 47 48 55 157 MXW8-50 71 4 30 46 76
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
B-1 2 L A A-1 1 B (B-2) 6 1 1.5m B (A-2) 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m (3) Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 S B (B-6) 9 B (A-6) 8 3 (14.2) (2 ) 2 1 (8) (1 ) B1 A1 (14) (18) (17.7) 6 5 (3 ) 2 1 B6 A6 15 16 (11) (30.7) 15.2 [820m] (1) (2) -L A B-1 2 A A-1 1 B (B-2) 6 8 8m* B (A-2) 5 COM-A/COM B-3 3 A 10m* COM-B/ A-3 4 B 15m* (3) Shield
-www.stevenengineering.com 38 55 MXY8 2.5 CX 43 63 MXY12 2.5 D51 -X Lead wire entries parallel 2-color Display Solid State Switch D-F9BW(V), D-F9NW(V), D-F9PV (mm) B A 20Model Mounting Switch operating range A B A B A B 50 MXY6 Data 38 55 4 MXY8 43 63 MXY12 51 Mounting of Auto Switch Caution Auto Switch Mounting Tool When tightening the auto switch set screw (included with auto switch),
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.
Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.