For detailed specifications, refer to page 10-20-1. 50 7 63 9 80 9.5 100 10.5 CV D-Z7/Z80 D-A3/A44 D-A3C, D-A44C D-A5/A6 D-B5/B64 D-A59W D-B59W D-Y5/Y6 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL D-G59F D-G39/K39 D-G39C, D-K39C MVGQ Electrical entry (Fetching direction) D-A53/A56 D-A64/A67 D-B64 D-Z80 D-F59/F5P/J59 D-F59W/F5PW/J59W
, D-F9P, D-F9B Auto Switch Specifications Grommet D-F9 (with indicator light ) D-F9B D-F9N D-F9P Auto switch part no.
D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5
(V), D-F9P(V), D-F9B(V) Auto Switch Specifications Grommet D-F9, D-F9V (with indicator light) In-line D-F9P D-F9N Perpendicular D-F9BV D-F9NV Perpendicular D-F9B Perpendicular D-F9PV Auto switch symbol In-line In-line Electrical entry 3-wire 2-wire Wiring method PNP NPN Output method IC circuit, Relay, PLC 24VDC relay, PLC Applicable load 5, 12, 24VDC (4.5 to 28VDC) Power supply 10mA or
D-B5, B6 20 to 100 D-G5, K5, G5W D-K59W 20 to 100 Hs Hs 24.5 24.5 B A B A Auto Switch Proper Mounting Position (Detection at Stroke End) (mm) Auto Switch Mounting Height (mm) Auto switch model D-M9 D-M9W D-G5/K59 D-G5W/K59W D-B5 D-B64 D-A9 Auto switch model D-G5/K5 D-G5W D-K59W D-B5/B6 D-M9 D-M9W D-A9 Bore size Bore size A 41 40.5 42 39 46 44.5 A 31.5 31 32.5 29.5 36.5 35 48 47 A 37 36.5
Output type Load voltage Lights when ON 2 color indicator Relay, PLC D-F9N D-F9NV NPN type 8mA or less 0.4V or less 28VDC or less 10A or less at 24VDC D-F9NW D-F9NWV D-F9P D-F9PV 12mA or less 24VDC (10 to 28VDC) 50mA or less Lights when ON 2 color indicator 10mA or less PNP type 1.5V or less D-F9PW D-F9PWV Lights when ON 4.5V or less D-F9B D-F9BV 1mA or less at 24VDC 24VDC (10 to 28VDC) 24VDC
D: Unit for replacement Ex.) If an adsorption confirmation switch is replaced for a vacuum switch on ZX1071-K15LZ-PBC, indicate as ZSE2-0X-15C-D. In this case, mounting screws P3270148-49 (2 pcs.) are required. If the unit is used on its own, not combined with others, D is not required. Ex.)
, D-F9WV D-F9P B, D-F9W D-A9V D-F9N D-F9V Number of auto switches 2 pcs. 15 (0.6) Note) 20 (0.80) Note) 10 (0.4) 10 (0.4) 5 (0.2) 10 (0.4) Note) 15 (0.6) Note) 20 (0.80) Note) 5 (0.2) 5 (0.2) 1 pc.
(n1L~n1H n2L~n2H) ON (20 ) Hysteresis "" 20 ON () (P1LP1H P2LP2H) ON (20 ) () 5%R.D.(5%) (0~1MPa 0.001MPa 1/1000) "()" () "" () ripple -12No.PS-OMH0005CN-D M38 L(2) (ZS-26-B) +(ZS-26-01) 48(ZS-26-D) 48 (ZS-26-D) () (ZS-26-01) (ZS-26-B) 90 IP65(48IP40) 1/41/2 0.58 mm -13No.PS-OMH0005CN-D 2 -14No.PS-OMH0005CN-D FG () AWG No.
D-F9N D-F9P D-F9B D-F9G D-F9H N.C. (B contact) N.O. (A contact) Contact Electrical entry In-line Wiring type 3 wire 3 wire 2 wire Output type PNP NPN NPN PNP 24VDC relay, PLC IC circuit, Relay, PLC IC circuit, Relay, PLC Applicable load Auto switch internal circuits Lead wire colors inside [ ] are those prior to conformity with IEC standards.
Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 283 314 220 251 157 188 94 126 314 63 OUT 20 10 236 212 189 165 142 118 94 71 47
Example Data Theoretical Output Minimum Stroke for Auto Switch Mounting OUT IN (N) (mm) Rod size (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 No. of auto switches mounted D-Y69 D-Y7PV D-Y7WV D-Y7BAL D-P5DWL 314 283 251 220 188 157 126 94 63 314 OUT 20 10 236 212 189 165 142 118 94 71 47
Insert D at the end of the manifold part number.
S: B Throo h hole standard A Both ends ta d L Foot mount F Rod side Iia e Head side flan e Type of Auto Switch , No auto SWitch built in (high magnetic Bore Size D Clevis mount . ~ field resIstance ma net 50 50mm P7G 0P10 63 63mrn l'l14C D-P74 80 80mm i P7 D-P75 Cylinder Stroke D-PS P8!
MY CY Proper Auto Switch Mounting Position MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 93.5 24.5 -X CYP32 122 33 20Data
Output Power Current Load Load Current Applicable voltage consumption voltage current leakage load drop D-M9N D-M9NV D-M9NW D-M9NWV NPN DC28V type or less At 10mA DC512 0.8V or 100A or Relay 10mA 40mA less less at PLC 24V or less or less IC circuit D-M9P D-M9PV D-M9PW D-M9PWV DC24V (4.5 to 28V) At 40mA 2V or less PNP type D-M9B D-M9BV D-M9BW D-M9BWV DC24V DC24V 2.5 to 4V 0.8mA or less (DC10