SMC Corporation of America
Elite Part Number Search
Search Results "CDQSB25-40D-M9B"

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 30mm, Option: Boss on Head Side, Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 10mm, Action: Single Acting Spring Return, Option: Rod End Male Thread, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 5mm, Action: Single Acting Spring Return, Option: Rod End Male Thread, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 10mm, Action: Single Acting Spring Extend, Option: Rod End Male Thread, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Thread: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com MHZ2 GRIPPER, PARALLEL. GRIPPER PARALLEL TYPE. ACTUATOR. 40MM MHZ2. 3.17769 lb. ME.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, GRIPPER, 2-FINGER, ACTUATOR, MHW2 GRIPPER, ANGULAR, ME, 40MM MHW2 DBL ACT W/AUTO-SW, 4.91315 lb, ModelBore size (mm)Effective gripping force (N?m)Opening angle (Both sides)Mass (2)(g) OpeningClosingMHW2-40D403.70180-52140

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, AUTO-SW, ACTUATOR, CQS COMPACT CYLINDER, IE, 25MM CQS DBL-ACT AUTO-SW, .66138 lb

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, AUTO-SW, ACTUATOR, CQS COMPACT CYLINDER, IE, 25MM CQS DBL-ACT AUTO-SW, 0.75102 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ACT, AUTO-SW, ACTUATOR, CQS COMPACT CYLINDER, IE, 25MM CQS DBL-ACT AUTO-SW, .77161 lb

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

M9BV M9B V V V v v Connector H7C J79C V V V V 3-wire (NPN) 5 V, 12 V M9NWV M9NW M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v v V

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, CLEAN ROOM, A/SW, ACTUATOR, CQS COMPACT CYLINDER, I5, 25MM CQS CLEAN ROOM, .92192 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, CLEAN ROOM, A/SW, ACTUATOR, CQS COMPACT CYLINDER, I5, 25MM CQS CLEAN ROOM, .87267 lb