When using a feedback sensor at higher than 50 mm, refer to the graphs below.
Grommet with waist Power cord outlet Grommet with waist 6 to 12 B A B C C A A 240 240 65 65 30 30 30 30 C 70 70 40 40 50 50 50 50 A 240 240 30 30 50 50 50 50 B 38 38 32 32 45 45 45 45 Model IDU6D IDU8D IDU11C IDU15C IDU22C1 IDU37C1 IDU55C IDU75C B 38 38 50 50 45 45 45 45 C 70 70 49 49 50 50 50 50 Model IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C Transformer box (1795) Power cord
Refer to "Flow Characteristics" (p.4.6-9) and figure of "Max. air flow" (p.4.6-8).
actuation input Signal PULS PULS SIGN SIGN CLR CLR BK COIN SG P-IN Signal S-ON P-ON P-OT N-OT ALMRST PCO SG ALM SG FG Pin no. 1 2 3 4 5 6 7 8 10 13 Driver model SGDE-A5AP SGDE-A5BP SGDE-01AP SGDE-01BP SGDE-02AP SGDE-02BP A B Normal rotation suppression input 50 55 Reverse rotation suppression input Alarm reset input PG output C phase 0V Servo alarm output 0V Frame ground 65 75 For LX Positioning
S. or l ess O perat i ng t em perat ure 0 t o 50( N o dew condensat i on) St andards CE m arki ng, U L( CSA) Encl osure I P65 I P65 equi val ent M odel I TV10 0 I TV20 0 I TV30 0 Si ze ( m m m m m m ) ( W i t h adapt or) 50 50 161 50 50 183 66 66 204 W ei ght ( N o opt i on) 330 430 730 9 Com m uni cat i on speci f i cat i on ( Com m on) I t em Speci f i cat i ons Rem arks Fi el d bus CCLi
Acid consumption [pH4.8](mgCaCO3/L) 100 or less 50 or less 50 or less Total hardness (mgCaCO3/L) 200 or less 70 or less 70 or less Calcium hardness (mgCaCO3/L) 150 or less 50 or less 50 or less Ionic state silica (mgSiO2/L) 50 or less 30 or less 30 or less Iron (mg/L) 1.0 or less 0.3 or less 1.0 or less Copper (mg/L) 0.3 or less 0.1 or less 1.0 or less Reference items Sulfide ions (mg/L)
weight per each 50 mm of stroke 0.09 0.11 0.16 0.25 0.39 Allowable Kinetic Energy by Air Cushion Mechanism R: Rod side, H: Head side P = 0.5 MPa Bore size (mm) Effective cushion length (mm) Allowable kinetic energy (J) 70 50 100 50 100 40 20 R: 0.35, H: 0.42 R: 7, H: 7.5 25 R: 0.56, H: 0.65 R: 7, H: 7.5 100 32 Total load weight (kg) 32 0.91 7.5 100 25 40 1.8 8.7 10 50 3.4 11.8 100 20 High
Real-time switch output Unit switching Hysteresis mode ON YES Display Real-time flow rate Accumulated flow OFF P-1 P-2 L/min L Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (L/min, L, m3 or m3x10) will be set for the type without the unit switching function.
Return 0.4 0.3 0.5 0.5 AV 0.2 0.1 0 2 6 4 8 1.0 0 25 50 75 1.0 AU 0.0 10 0 25 50 75 100 100 Input signal (%F.S.) Repetition Input signal (%F.S.)
Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability 0.1C Temp
Note 1) Consult P/A if other specifications for surface treatment are required.
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override
Consult P/A when guaranteed accuracy is required for MY1C/MY1H. Note 2) Accuracy indicates displacement of the table (at stroke end) when 50% of the allowable moment shown in the catalog is applied.
C 5 to 45 Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity 50/60 Hz3 kW 8.0/9.0 Heating capacity 50/60 Hz4 kW 1.7/2.2 Temperature stability5 C 0.5 Circulating fluid system Rated flow 50/60 Hz (Outlet)6 L/min 29/45 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50
E TH TF WF LF + Stroke UF ZJ + Stroke A Bore Size (in) MM KK A B E EE FB LF+ P+ R TF TH UF W WF ZJ+ 500 (5") 1.000 3/4-16 1.13 1.500 5.50 1/2 NPT .50 4.50 2.88 4.10 6.63 2.75 7.63 .75 1.38 5.88 600 (6") 1.375 1-14 1.63 2.000 6.50 3/4 NPT .50 5.00 3.13 4.88 7.63 3.25 8.63 .88 1.63 6.63 MF2 Head side rectangular flange (G) P + Stroke 4-FB 2-EE KK MM B R E TH WF LF+ Stroke TF ZJ + Stroke UF
Flange size XMH Symbol Nil C XMH V V V V XYH V V V Type KF (NW) CF Applicable flange size 16, 25, 40, 50 16 (034), 40 (070) Size 16 25 40 50 XYH Nil KF (NW) 25, 40, 50 3.
VQ VQ4 VQZ VQD VZS VFS VS VS7 1.13-9 Series VQD1000 Dimensions Plug lead unit manifold(VV4QD12-l) Lead wire length: 300mm 4-Rc(PT)1/8 (P, R port) Light 2-4.5 (Mounting hole) 57 50.5 5.3 5.3 52 0.6 1 3 P R 1 3 R P 30 17 6.5 15 7 10 P=11 0.5 0.5 2n-M5 (A, B port) L2 35 4 M5: M5 thread L1 38 42 M plug connector (M) Station 1 2 3 4 5 n D side U side Direct manual override (Non-locking) 24 15
230 V (50 Hz) Three-phase 200 V (50 Hz) Three-phase 200/220 V (60 Hz) IDU37E R1 1/2 37 215.4 201.3 IDU55E 55 346.0 296.6 R2 IDU75E 75 441.4 388.4 Refer to the separate catalog.
The theoretical output for extension is 1924N, from the theoretical output table on page 5. 20 80 50 50 50 40 60 40 40 30 40 20 10 0 0 Note: 1kg = 2.2046lb 1in = 25.4mm 1MPa = 145psi 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Operating pressure P (MPa) Operating pressure P (MPa) Selection Graphs to (Horizontal Mounting) Graph l: 100mm or less Graph l: 101 to 200mm Graph l