Mount the magnet lever (18) to the joint (12) and fasten it using the hexagon socket set screw (24). 4. Mount the stopper ring (3) to the cover (A) (14) and fasten it using the cross recessed round head screw (20) (tightening torque is approx. 0.8 Nm). 5.
Minimum rotation angle that will not allow decrease of energy absorption ability (Internal shock absorber type) Size 10 20 30 50 70 100 200 Minimum rotation angle that will not allow decrease of energy absorption ability 52 43 40 60 71 62 82 Table 3.
Stroke Adjustment Unit Specifications Applicable bore size (mm) 25 L RB1007 + with adjustment bolt 0 to 11.5 11.5 to 23 23 to 34.5 32 L RB1412 + with adjustment bolt 0 to 12 12 to 24 24 to 36 40 L RB1412 + with adjustment bolt 0 to 16 16 to 32 32 to 48 Unit symbol Configuration Shock absorber model Without spacer With short spacer With long spacer Stroke adjustment range by intermediate fixing
Grommet, Grommet terminal, Conduit terminal DIN terminal, L plug connector, M plug connector Electrical entry VT 100, 200, 12, 24, 48, 110, 220, 240 AC (50/60 Hz) DC Coil rated voltage (V) VP 24, 6, 12, 48, 100, 110 Allowable voltage fluctuation 15 to 10% Inrush VG 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA/50 Hz, 2.3 VA/60 Hz 1.8 W 2 W Note) Apparent power (AC) Holding W/o indicator light W/ indicator
49.5 47 11 8.5 2-cushion needle Width across flats 8 4.5 4.5 Rod cross section 6 4.5 2-M5 x 0.8 (port size) 5.5H7 +0.012 0 10h7 0 0.015 16 0.2 4-M5 x 0.8, effective length 8 24 0.2 4-4.5 through 2 x 4-7.5, counter bore depth 4.5 (opposite side also) 14 15 4 28 0.2 28 0.2 38 36 26 53.5 102.5 + Stroke 18 25 M5 x 0.8 120.5 + Stroke 16 0.2 22 24 0.2 4-M5 x 0.8, effective length 8 Rod end male
SYJ314 N.C. 52 (Without sub-plate 31) 50 (Without sub-plate 29) Base mounted type (With sub-plate) M5 0.8 1.8 (0.1) SYJ324 N.O.
24 to 36 0 to 16 16 to 32 32 to 48 Stroke adjustment range by Intermediate fixing spacer (mm) MY1 W Stroke adjustment range is applicable for one side when mounted on a cylinder.
Cable: 3 core 24 x AWG White: B side solenoid ( ) (not used for single solenoid) For different lead wire lengths, order a lead wire assembly with connector shown in the table on the right. Note) There is no polarity. It can also be used as a negative common.
(Refer to Front matter 23 "Particle generation measuring method"and Front matter 24 "Comparison of cleanliness standards" for details.)
13 15 25 24 HA 17 24 30 36 41 52 62 80 92 G 3 4 5 6 6 7 7 8.5 8.5 HT 10.5 14 17 24 23.5 29 36 45 51 J x E M4 x 0.7 x 6 M4 x 0.7 x 6 M5 x 0.8 x 7 M6 x 1 x 8 M6 x 1 x 8 M8 x 1.25 x 10 M8 x 1.25 x 10 M10 x 1.5 x 15 M10 x 1.5 x 15 B 6.5 8 9.5 9.5 11 11 14 14 GP 20 27 33 39 44 55 65 83 95 HB 10.5 14 17 21 23.5 29 36 45 51 C 3.2 4.2 5.2 5.2 6.5 6.5 8.2 8.2 GW 18.5 25.5 31.5 37.5 42.5 53.5 63.5
Application Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC Style Reed switch Auto switch part no.
Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only Note) Electrical entry: D or DZ only 4 Note 1) 4 Note 1) 5 6 Note 1) 5 6 Note 1) Manual override CEcompliant 7 Note 1) 7 Note 1) Electrical entry Nil Non-locking
Load voltage Electrical entry Lead wire length (m) Flexible lead wire (-61) Applicable load Pre-wire connector In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Auto Switch model Special function Electrical entry Indicator light Wiring (Output) Type Perpendicular 3-wire (NPN) 3-wire (PNP) 24 V 12 V M9NV M9N IC circuit Solid state switch M9PV M9P Relay, PLC Standard Grommet Yes 2-wire M9BV M9B Water
Load voltage Electrical entry Lead wire length (m) Flexible lead wire (-61) Applicable load Pre-wire connector In-line 0.5 (Nil) 3 (L) 5 (Z) DC AC Auto Switch model Special function Electrical entry Indicator light Wiring (Output) Type Perpendicular 3-wire (NPN) 3-wire (PNP) 24 V 12 V M9NV M9N IC circuit Solid state switch M9PV M9P Relay, PLC Standard Grommet Yes 2-wire M9BV M9B Water
Accessories 21 to 24 (Options) 25 Technical Data Pressure dew pointCondensed water calculation chart, Pressure dew point temperatureAtmospheric pressure dew point temperature conversion cart Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity.
Series SV2000 for EX120 Dedicated Output Serial Wiring. 6 7 8 10 10 10 10 10 10 10 11 11 11 11 11 11 12 12 13 13 13 15 16 16 17 19 20 21 21 23 23 24 24 24 24 24 25 26 27 27 30 30 31 32 33 34 35 36 37 37 39 40 40 41 42 44 45 45 50 50 51 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
50 80 5 6 4 8 M10 x 1.5 20 24 63 106.5 118 161 25 4.5 16 59 63 End lock mechanism dimensions MGPL (ball bushing)/A, DB, E dimensions (mm) (mm) E A HN (Max.)
38 Interface cover 12.5 12.5 80 29 CN3 connector (D-sub 9P) 75 Mounting bracket 244 24 196 24 55 Series LC1 Series LC1/Operating Part Names Encoder/Limit switch signal connector: CN4 Control terminal: CN1 General-purpose input/output: CN2 Motor power connector: CN5 Power supply terminal: TB Connector: CN3 Controller Command Setting List Actuator Control Commands Parameter value Classification
24 129.5 147 170 163 180.5 203.5 175.5 193 216 219.5 237 260 222.5 240 263 229.5 247 270 55 63 74 1 2 1 2 17-4-9 6 Series VNA Precautions Be sure to read before handling.
The low profile design saves space and s2 reduces bending moments. b. 52 reuuuEs ucl|ulrg rl|ul|l -. iil _] 'lmproved accuracy with smooth operation J | . . ^ , " ^ Height is approximately 1/3 the size ol an equivalent Series MHZ2.