SMC Corporation of America
Elite Part Number Search
Search Results "HRR050-AN-40-T1UY"

28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.

In addition, it can relay output as an alarm contact output when an alarm is generated. Alarm Alarm code Alarm description Operation status Main reason AL0 Memory error Stop There is an abnormality with the memory data in the controller due to a high level of noise. AL1 Controller error Stop There is an abnormality with the data in the controller due to a high level of noise.

Vibration (Supply pressure: 0.1 MPa) Lifting force (N) 0.5 30 Cyclone type 0.4 ZP3 0.3 0.01 mm or less 20 0.2 Amplitude (mm) ZP3E 0.1 10 0 Low profile cyclone type ZP2 0.1 0 20 40 60 80 100 0 0.2 ZP2V Size (mm) 0.3 Totaled 5 size: 20/40/60/80/100 0.4 ZP 0.5 0 0.5 1 1.5 2 2.5 Low profile cyclone type Totaled 6 size: 40/60/80/100/ l120/l150 ZPT ZPR Time (sec.)

In such a case, give an additional tightening to the tube connection part. If leakage still occurs after giving an additional tightening, replace the fitting with a new product. For other precautions, refer to Fittings & Tubing Precautions. When using the fluoropolymer fittings, refer to the precautions on pages 445 and 446. Select the size after confirming O.D. and I.D.

Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C (68F) with an outside diameter rate of change of 10% or less. At higher temperatures the outside diameter rate of change may exceed 10% within the minimum bending radius.

Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C (68F) with an outside diameter rate of change of 10% or less. At higher temperatures the outside diameter rate of change may exceed 10% within the minimum bending radius.

The wireless slave unit does not operate with the set input/output size. 8 Check the system configuration on the Information tab of the wireless master to identify the unit with an error. Check the diagnostic information from the Description to identify the error. For diagnostic information of each unit and details, refer to section 3.4.1 Information tab (page 40).

The wireless slave unit does not operate with the set input/output size. 8 Check the system configuration on the Information tab of the wireless master to identify the unit with an error. Check the diagnostic information from the Description to identify the error. For diagnostic information of each unit and details, refer to section 3.4.1 Information tab (page 40).

500 500 500 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 0 10 20 30 40 50 60 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 Mey 1500 1500 1500 1500 L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 1000 1000 1000 1000 Wall L5 Y 500 500 500 500 0 0 0 0 4 8 12 16 20 24 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 16 0 10 20 30 40 50 60 Work load [kg] Work load

In the ON condition an indicator LED will show, and any connected load will be powered. In the OFF condition, there will be no indicator LED and no power supplied to the load. An output showing such behavior is called switch output.

An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. d. When used in an interlock circuit, dual interlock such as mechanical protection is necessary in case of accident. Periodical inspection is also necessary to confirm proper operation.

Furthermore, an abnormal temperature rise due to adiabatic compression can cause tubing to burst. Note 3) The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less. At higher temperatures the outside diameter rate of change may exceed 10% within the minimum bending radius.

Nil C 0.4 to 4 l/min 1.8 to 20 l/min 4 to 40 l/min 04 20 40 The cable and connector are shipped unassembled.

1 Stainless Steel Cylinder Series CJ5-S Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Applicable for use in an environment with water splashing such as food processing, etc. RE A B REC Uses grease for food processing machines that meets FDA (U.S.

1 Stainless Steel Cylinder Series CJ5-S Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Applicable for use in an environment with water splashing such as food processing, etc. RE A B REC Uses grease for food processing machines that meets FDA (U.S.