SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-N-M5-BY"

Nominal thread sizes Tightening torque M5 1/6 rotation after tightening by hand R 1/8, NPT 1/8 7 to 9 Nm 3. Apply wrench only to the metal part of the main housing when installing the pressure switch onto the system piping. Do not apply a wrench to the resin part as this may damage the switch. 10 Series ZSE30/ISE30 Digital Pressure Switch Precautions Be sure to read before handling.

The circulating fluid is sent to the evaporator by the inverter pump, and is controlled to a set temperature by the refrigeration circuit, to be discharged to the users equipment side again by the thermo-chiller.

lbf N lbf N lbf (mm) N lbf N lbf IN 4 12 0.9 3.1 14 0.24 6 65 20 0.175 113 43 4.5 OUT 14.6 9.7 IN Spring return Spring extend 6 16 1.3 3.4 15 8 0.31 126 45 0.312 201 OUT 86 10.1 28.3 19.3 IN 6 20 1.3 3.4 15 10 0.39 204 78 0.487 314 OUT 141 17.5 45.9 31.7 IN 11 25 2.5 4.7 21 12 0.47 323 126 0.761 491 OUT 224 28.3 72.6 50.4 48 14 0.131 84.8 IN 31 3.1 10.8 7.0 3 12 0.7 2.2 10 0.24 6 OUT 85

CRJ1 CRJ05 Model 30 25 Fr Allowable load (N) 25 20 FS(a) 25 20 FS(b) 6 5 Pinion gear Output shaft size (mm) Stopping the pinion gear by having it strike against the flat surface of the piston eliminates backlash.

M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Plug connector Large flow capacity Standard V14:13(27) V14A:16(30) V14:12(26) V14A:15(29) Large flow capacity V124A Note 1) 1 2 Flow characteristics 2 3 V100 Valve model C[dm3/(sbar)] 0.037 0.076 0.054 0.099 C[dm3/(sbar)] 0.054 0.099 0.037 0.076 b 0.11 0.070 0.35 0.23 b 0.35 0.23 0.11 0.070 Cv 0.0080 0.016 0.015 0.024

Rotate the handle by hand. 1. Conrm the mounting direction of the product. Direction of gas flow from inlet to outlet is indicated by an arrow on each label. Orient the valve as specied by the system designer. 2. Connect actuation pressure to the valve actuator connection. (Air operated type) Use nitrogen or clean dry air for actuation pressure. The connection M5 thread.

Rotate the handle by hand. 1. Conrm the mounting direction of the product. Direction of gas flow from inlet to outlet is indicated by an arrow on each label. Orient the valve as specied by the system designer. 2. Connect actuation pressure to the valve actuator connection. (Air operated type) Use nitrogen or clean dry air for actuation pressure. The connection M5 thread.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHL2-16D1 2 MHL2-10D1 2 MHL2-10D MHL2-10D MHL2-16D 60 60 25 Pressure 0.6 MP 0.6 MPa Pressure 0.6 MPa 25 Pressure 0.6 MPa Pressure 0.6 MPa Gripping force (N) Gripping force (N) Gripping force (N) Gripping force (N) 50

Bore size NTJ-010A NTJ-006A 8 6 M3 x 0.5 2.4 5.5 6.4 5.5 6.5 M3 x 0.5 6 12.5 M4 x 0.7 3.2 7 8.1 7 8.5 M4 x 0.7 8 14.5 NTJ-015A 10 M5 x 0.8 4 8 9.2 10.5 M5 x 0.8 16.5 10 9 (mm) Standard C D E F B A J K L M N O P G H I Bore size 8 6 M2.5 x 0.45 13 7 7 10 9 19 3 5 4 9 3.5 8 7 5.3 24 M3 x 0.5 13 7 8 11 10 21 3 6 5 11 4.5 10 8 5.3 25 10 13.5 M3 x 0.5 7 8.5 11.5 10.5 22 3.2 6 6 12 5 11 8.5 5.6

M5 female thread, through type M3 M3 x 0.5 ISA2 IM5 M5 M5 x 0.8 IS Option/Part No. M5 female thread, through type (With mounting hole) 01 R 1/8 (With M5 female thread) IM5H Note Description Part no. N01 NPT1 /8 (With M5 female thread) ZSM Connector for PSE200 1 pc. ZS-26-E-4 R04 4 plug-in reducer Connector for PSE300 1 pc.

pcs.+ L16 x 2 L8 x n pcs.+ L17 x 2 L8 x n pcs.+ L25 x 2 L8 Refer to page 6 for L8.

-1-31.5-4-M5 Connector configuration of the accessory One side M8 8 pin connector(Socket) One side M12 8 pin connector(Plug) *1 Theoretical holding force (reference value) when a low carbon steel plate is held by entire surface attraction *2 In the default setting, the auto switch is fixed at the workpiece release position. * For examples of setting auto switch and setting of mounting position

Made to Order Intermediate Stroke Type 2 Intermediate strokes in 5mm increments can be manufactured by installing spacers inside standard stroke cylinders.

Average speed of cylinder is obtained by dividing the full stroke time by the stroke. Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% The histograms with marked are the case when piping is done by using steel.

(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399 388 L1 L2 5 Series VKF300 Dimensions/Manifolds Base Mounted Type Common SUP, Common

x 0.8 Rc 1/8 Rc 1/8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M3 x 0.5 Except lock unit, 0.12 MPa for 12 and 16; 0.10 MPa for 20 to 40 respectively.

&Warning Moreover, the needle valve is closed by turning fa the right. and opened by turning to the left; and therefore, the actuator speed is reduced by turning to the right and increased by turning to the left. 1.This product cannot be used as a stop valve requiring zero air leakage.