entry O-ring + Wiring top entry Digital pressure switch (Body only) 25 65 NPN output Output PNP output + Lead wire With unit conversion function Nil Note 2) M P Note 2) Unit Note 1) Fixed SI unit Pressure unit: psi (Initial value), with unit conversion function + Nil L Without lead wire Lead wire Lead wire with connector (2 m) + Nil Without accessories (Switch body only) Accessories With
Symbol Name PA06 CMX Electronic gear numerator 1 0 to 65535 PA07 CDV Electronic gear denominator 1 1 to 65535 Set the values as follows. 1 [PA06] M = 1000 [PA07] Actuator lead (L) [mm] n1/n2 M : [Servo motor resolution : 262144(Pulse/rev)] n1/n2: Pulley ratio *1 EX.)
_OUT2 6 N.C. 5 N.C. 4 White CH1_OUT2 3 Black C/Q (CH1_OUT1) 2 Blue L 1 Brown L+ 4 Black: 3 Blue: L C/Q (CH1_OUT1) 100 42.5 Front protection cover + Panel mount adapter 53 55 or more 47 37.5 +0.1 0.2 (2) 9.4 42.4 46.4 55 or more 4 x R1 or less Front protection cover Panel mount adapter Panel Waterproof seal m48 conversion adapter + Panel mount adapter (2) 6 1.5 48 Panel fitting dimensions
S 100 L Flow control valve (With pressure compensation) Enables constant movement even if there are load fluctuations.
N.O. 101.2 kPa to 0.2 VPA344 544 744 Pilot pressure (MPa) Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note) Same as operating pressure (Min. 0.2 MPa) 10 to 50C (No freezing. Refer to page 5-11-4.) Not required (Use turbine oil Class 1 lSO VG32, if lubricated.)
-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc 1/8 Pilot air port size RHC MK(2) Oil port size Rc RS Q G Throttle valve locking screw RS H A RZQ Oil port size Converter side Oil port size Cylinder side 2-S Wall mounting screw Unit port U1, U2 MI W S CEP1 CE1 CE2 (mm) Model Oil port size Rc A B CA CL GB GL KA KB KL L QA M NB NL QB QL R T GA 18
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 71.00000 lb
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nil Without cable Sensor cable (3 m) M5 Port size L M5 x 0.8 Option Sensor cable (3 m) + Connector (1 pc.) When only optional parts are required, order using the part numbers listed below.
(A) 2 L: L style (VQ20 Only ) 1 1 (p) Note) Consult SMC if N.O. is desired. Note) If ordering both options, indicate "LF".
LVN TI/ TIL PA PAX PB 0.8 MPa Po = 0.3 MPa Po=0.3 Mpa Initial pressure (Pressure at valve closing) Initial pressure (Pressure at valve closing) SGP piping length L (m) 17-3-59 8 The VX series will be revised shortly.
XLD-63 XLD-80 XLD-25 XLD-40 XLD-50 XLD-100 XLD-160 0.08 Nm 0.3 Nm 6-3.S S S S 6-4.M M M S 6-5./ S M S M 12 XL-OMY0002 7.
Ambient and fluid temperature M Symbol No grease is used.
bracket) are included with the above parts. 3 Direct Operated 2 Port for Heated Water Series VCB Dimensions Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port
Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection PA14 0 1(+Counter motors side) Load to motor inertia moment ratio PB06 7 7 Function selection E-3 PE41 0 0 LEFS25(L,R)T6 LEFS32(L,R)T7 LEFS40(L,R)T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
/min (ANR)) Air flow rate (l /min (ANR)) AMH550 AMH250 B B 3 4 1 4 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) AMH650 AMH350 B 1B 3 8 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) 0.5 Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow
VQZ100 ( ( ( ( ) ) ) ) 90 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 DC L,M L,M L,M L,M
Bore size Cylinder stroke (mm) Refer to the standard stroke table on page 2. 20 25 32 40 20mm 25mm 32mm 40mm Applicable auto switches Lead wire length (m) Load voltage Wiring (output) Special function Auto switch model Indicator light Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC C76 B53 B54 B64 C73 C80 C73C C80C 3-wire (NPN equiv.) 5V Yes IC circuit PLC 200V
bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 52 AL10 to 60 Dimensions AL10 AL20 L D Bracket (option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50, 60 AL30, 40 L D D L Port size Bracket (option) Bracket (option) G F G F Port size M K M K E J C B R C B R H
This is recommended because it can absorb off-centering, compared with direct mounting type. 6.1 16 M 5 Part name Part number P368010-24 Fork lever assembly M N P368010-25 Fork lever assembly S Resin connector (Non-explosion proof specification) L2=31 (M type: 55) 39 (M type: 63) Optional cable connectors are available for different cable sizes.