switches mounted Type Auto switch model Auto switch model 32 40 50 63 80 100 2 (Different sides, Same side) D-Z7/Z80 Reed switch 15 25 10 10 11 11 12 D-Z7/Z80 10 1 D-Y59/Y69 2 (Different sides, Same side) D-Y59/Y69/ D-Y7P/Y7PV 6.5 6.5 6 7 7 8 15 25 D-Y7P/Y7PV 1 D-Y7W/Y7WV 6.5 6.5 6 7 7 8 2 (Different sides, Same side) Solid state switch D-Y7W/Y7WV 20 25 1 6 D-Y7BAL 5 5 5 5 5 2 (Different
6 FB 4 Shield ground SHIELD 9 Optical fiber (reserve) RTS 12 PS Pin no. 3, 5, 7, 8, 10 and 11 marked with "" are open.
OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-R005 Contents 6.2.1 Option M [DI water (Pure water) piping] . 6-2 6.3 Optional Accessories [Electric resistivity /conductivity sensor set] . 6-2 6.3.1 Optional Accessories [Electric resistivity/conductivity
Cushion J MSU 80 to 100, 170 to 190 Rotating angle K Double round shaft Port size Rc 1/8, G 1/8, NPT 1/8, NPTF 1/8 M5 x 0.8 CRJ Mountable Auto switch CRA1 Dimensions CRQ2 J K T Shaft type Size 20, 30, 40 MSQ MSZ CRQ2X MSQX CRQ2X MSQX MRQ Form Size 10, 15 D (g6) G W H M N UT UJ UK Size 10 15 20 30 40 5 4.5 18 9 6 35 44 53 6 5.5 20 10 7 40 50 60 8 0 0.1 10 0 0.1 11 0 0.1 10 30 15 11 59 74
OptionOptional Accessories . 6-1 6.1 Option J [Automatic fluid filling] . 6-1 6.1.1 Option J [Automatic fluid filling] . 6-1 6.2 Option M [DI water (Pure water) piping] . 6-2 HRS Series HRX-OM-O021 Contents 6.2.1 Option M [DI water (Pure water) piping] . 6-2 6.3 Optional Accessories [Electric resistivity /conductivity sensor set] . 6-2 6.3.1 Optional Accessories [Electric resistivity/conductivity
1.85 2.09 2.52 2.78 3.10 3.34 [kg] 0.12 0.19 1 2 3000[mm/s 2] 320%(F.S.) 450%~95% 7.2[]P41 LEY 5 6() 452000Hz 1 () 7 8 9 10 11 -14- 3.2.
1 6-5 . 6-4 7 A 7-1 . 7-1 7-2 . 7-1 7-3 . 7-1 7-4 . 7-1 7-5 . 7-2 8 C 8-1 . 8-1 8-2 . 8-1 9 K 9-1 . 9-1 9-2 . 9-1 10 L 10-1 . 10-1 10-2 . 10-1 10-3 . 10-2 11 M 11-1 . 11-1 11-2 . 11-2 11-3 . 11-2 11-4 . 11-2 12 R 12-1 . 12-1 12-2 . 12-1 12-3 . 12-2 12-4 . 12-2 12-5 . 12-2 13 T 13-1 . 13-1 13-2 . 13-1 13-3 . 13-1 13-4 . 13-2 13-5 . 13-2 13-6 . 13-3
;p R .S, .0 Applicable tube (mm) OIl 6 24.3 16.8 12.8 ' >'8 If ~ . 2 lt8:7 .15.2 Applic;;bfQ tubli q.D 11? Q. R' ' ~ .4 4 23.3 1 5.8 10.4 .
Body rotates at 360 around the stud axis. 6/4-M5 6/4-M5 MS-5ATHU-6 MS-5HLH-6 P. 133 P. 134 Applicable MS-5ALHU-6 MS-5HLH-4 MS-5HLH-6 MS-5ATHU-6 only Gasket Gasket(H) To seal M5 thread. M-5GH To seal M5 thread M-5G1 P. 134 P. 134 132 Miniature Fittings Series MS Barb fitting for soft nylon: MS-5AU-3, -4, -6 Effective orifice(mm 2) Weight (g) D L Part No.
to 800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Stroke range Bore size (mm) MM XA Y ZZ MA MB MC NA NB P S M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M12 x 1.75 6 6 12 12 16 16 20 5 6.5 8.5 9.5 12.5 15 20 106 128 155 178 195 221 248 11 11 16 16 16 16 20 10 10 12 12 15 15 23 19 26 21 34 86 107 120 138 150 171 198 4 4 4 4 5 5 6 20 25 32 40 50 63 80 M5 x 0.8
Applicable bore size (mm) 32, 40 UA C d1 d2 H K L UT Weight (g) 25 9 YB-03 32, 40 6.5 10 18 50 80 YU-03 15.8 14 M8 x 1.25 8 7 17 6 11 11 YB-05 50, 63 6.5 12 22 60 120 YU-05 50, 63 19.8 18 M10 x 1.5 10 40 7 17 6 13 YU-08 M16 x 2 80 24.8 23 13 90 9 22 8 20 14 YB-08 80 8.5 16 28 75 230 YU-10 M20 x 2.5 100 29.8 28 14 160 11 26 10 26 18 YB-10 100 10.5 18 36 90 455 9-10-25 25 Series CLQ Proper
11 95 90 50 100 113 60 89 41 5 25 10 55 20 20 11 12 115 110 60 Mounting type E Bore d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 32 11 10 6.6 38 51 10 21 7 18 26 31 32 8 10 40 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 50 15 12 9 50 65 12 33 11 30 32 45 45 12 12 63 15 16 9 52 67 14 37 11 35 40 50 50 12 15 80 18 16 11 66 86 18 47 12.5 40 50 60 63 14 15 100 18 20 11 76 96 20 55 13.5 50 60 70
-5 6 B B-6 9 B A-6 8 3 14.2 2 1 (5.5) 14 B1 A1 5 6 17.7 2 1 18 A6 B6 (6.3) 15 16 11 30.7 44 - 113 [5m ] A B-1 2 A A-1 1 L B B-2 6 B A-2 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 S 4 B-1 5 A-1 1 B-3 2 A-3 (8) 14.2 B1 A1 17.7 2 1 14 18 6 A6 B6 5 10.2 B1 A1 2 1 B3 A3 (5.7) 15 16 11
4 6 6 4 21 Bore size (mm) 20 6 6 1.5 (1) 3.5 3.5 22.5 10 7.5 2.5 10 7.5 24.5 25 7 7 3.5 (1) 5.5 5.5 24.5 11 9.5 0.5 11 9.5 26.5 ( ): Denotes the values of D-A93.
Adjustment method 6 3.1 Vertical auto switch unit 6 Operating Range and Hysteresis 6 Auto Switch Mounting 7 Auto Switch Adjustment 10 3.2 Angle adjustment unit 11 Rotating angle with angle adjustment unit 11 Rotating Angle Adjustment Method 11 4.
4 (7.5) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 4.5 (1.5) 4.5 (1.5) 9 (5) 12 (7.5) 14 (10) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 3 (0) 3 (0) 7.5 (3.5) 10.5 (6) 12.5 (8.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 5 (2) 5 (2) 9.5 (5.5) 12.5 (8) 14.5 7.5 8.5 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 11.5 (8.5) 11.5 (8.5) 16
M5 x 0.8 depth 5 M5 x 0.8 depth 5 (Vacuum port) DC DB DA High precision type 11-MSQAA 11-MSQAR Basic type 11-MSQBA 11-MSQBR DC DB DA (Vacuum port) HB HB HA HE (HD) (HD) 11.5 5.5 HC HC DD DD (mm) (mm) DA(h8) DB(h8) DC(h8) DD(h8) HA HB HC HD HE DA(h9) DB(h9) DC(h9) DD(h9) HB HC HD Size 10 20 30 50 Size 10 20 30 50 46 45 20 35 15.5 24 5 63 9.5 46 45 20 35 20 5 59 61 60 28 40 19.5 30 6 73 13.5
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
9, @6, #2, #3, #4, #6, #8, #9, $9 11-10-11 12 Series MRQ Size 32 Basic Style: MRQBS32 Note) M6 x 1 depth 7 (MAX. 12) Number of mounting screws and distance between screws are different depending on the strokes. Refer to the Mounting screw dimensions (Distinction of stroke) below.