7 NBR Valve retainer seal #7 * Since ther is a possibility of improper operation, contact SMC regarding the replacement of seals. 4.4-9 Series CE1 Dimensions 12, 20 Both ends tapped CE1B Bore size Stroke (mm) A B C D E G H I K L M Bore (mm) 12 20 Standard stroke 25, 50, 75, 100, 125, 150 94 M5 X 0.8 16 5.2 25 15.5 69 15 6 25 42.5 25, 50, 75, 100, 125, 150, 175, 200 106 78 15.5 10 36 53.5
Oscillation Angle A: 100°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves: Provided
Oscillation Angle A: 100°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves: Provided
D-M9B D-M9N, D-M9P D-A93 Load voltage Load current range Indicator light Application 24 VDC (10 to 28 VDC) 28 VDC or less 24 VDC, 100 VAC 2.5 to 40 mA 40 mA or less 5 to 40 mA, 5 to 20 mA 24 VDC relay, PLC IC circuit, Relay, PLC Relay, PLC Solid state auto switch PLC: Programmable Logic Controller Refer to page 920 for the applicable auto switch list. 905 Rotary Actuator 11-CRA1-Z Rotation
The load voltage is 100 or 200 VAC. A contact protection box should be used in any of the above conditions, Unless using a contact protection box, the contact life may be shortened. (Due to permanent energizing conditions.) D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length.
Kinetic Energy(J): 0.54, Operating Pressure Range(MPa): 0.1~1.0, Size: 100, Switch: A93, Lead wire(m): 3, Number Of Switches: 2 pcs., Port types: Rc, Shaft pattern: Single shaft, Made to order specifications: Both sides angle adjustable type, Mounting Style: Basic type, Starting point of rotation: Right, Connector Type: None, Specification: With auto switch unit, Port direction: Standard
Kinetic Energy(J): 0.54, Operating Pressure Range(MPa): 0.1~1.0, Size: 100, Switch: A93, Lead wire(m): 3, Number Of Switches: 2 pcs., Port types: Rc, Shaft pattern: Single shaft, Made to order specifications: None, Mounting Style: Foot, Starting point of rotation: Right, Connector Type: None, Specification: With auto switch unit, Port direction: Standard
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves: Provided
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves: Provided
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves: Provided
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
SMC's new NCQ8 series is a square body, compact cylinder that allows close center to center mounting. Visibility of auto switch is improved over the NCQ7 series and is mountable on multi-sides. Use of the retaining ring method improves maintenance performance. Replacing seals is easily obtained by removing the collar. Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum
SMC's new NCQ8 series is a square body, compact cylinder that allows close center to center mounting. Visibility of auto switch is improved over the NCQ7 series and is mountable on multi-sides. Use of the retaining ring method improves maintenance performance. Replacing seals is easily obtained by removing the collar. Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum