Lead wire length symbols 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Refer to page 14 for additional details and applicable auto switches other than the above types.
9 to @2 20Solenoid valve with adapter assembly SYJ3 3-M VZ5 4 -M VF3 4 -M VZ3 4 -M A B A B A B A B @3 Data Note 1) Seal kit includes !9 to @2. Order the seal kit, based on each bore size.
Lead wire length symbols 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Refer to page 14 for additional details and applicable auto switches other than the above types.
Parameter Configuration using Setup software (MR Configurator2TM) . 14 6.1 Setup software (MR Configurator2TM) .14 6.1.1 Installation Method . 14 6.2 Basic driver set-up for Initial Test Drive .14 6.2.1 Start up the Setup software (MR Configurator2TM) . 15 6.2.2 System Settings . 16 6.2.3 Model Selection . 16 6.2.4 Driver ON LINE Check . 17 6.2.5 Help Function . 17 6.3 Parameter setting (
Made to Order How to Order Transition wiring cable length IZS41 CF X13 For IZS40 Cable full length 1 m 3 m Symbol 01 03 Model with Made-to-order transition wiring cable Available in 1 m increments from 1 m to 20 m. Note 1) 11 m or longer power cables are not CE Marking-compliant. Note 2) Use standard power supply cables for 2 m, 5 m and 8 m lengths.
Applicable shaft types: K, T Equal dimensions are indicated by the same marker. 20L1 = L1 = L1 L1 = Q1 = M Q1 = M Q1 = M L1 = L1 Q1 = M L1= Q1 = M K axis L1 T axis Q1 Q1 (mm) Q1 Q1 L1 L1 Size Thread M 3 x 0.5 M 4 x 0.7 M 5 x 0.8 M 6 x 1 M 8 x1.25 M10 x 1.5 Rc 1/8 Q1 (mm) 20 30 10 15 40 J axis Z axis (mm) Size Thread M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 2.5 2.5 3.3 2.5 3.3 4.2 5
on opposite side) 63 24 M5 x 0.8 3-R3 2 4 Finger opening port 17 32 23 27.5 7 11 45 42 69 8 54 2-8.5 through 2-14 depth of counter bore 14 107 Angle adjustment bolt 3-R3 12 3-6H9 depth 8 (one each on three sides) +0.030 0 10 3-6H9 long groove depth 4 (one each on three sides) +0.030 0 M5 x 0.8 Port B M5 x 0.8 Port A 50h9 0 0.062 4-M6 x 1 Depth 10 I N J E A D P A A M N R SMC R E O P 17 P
(Except D-P5DWL type) Thread type Port thread Mounting thread Bore size Symbol Cylinder stroke (mm) 12 to 25 M thread Rc NPT G M thread NPT Nil For Standard Stroke and Manufacuture of intermediate of Stroke, refer to page 7-5-3. M thread TN TF 32 to 50 12 to 25 32 to 50 NN Inch thread Note 3) M thread to be used for without auto switch type of 32, 5 stroke exceptionally.
ZP25B ZP 32 B ZPG32B-7A-X2 14 15 15 18 ZP32B ZP 20 UT ZPG20UT-7A-X2 4 4 4 4 ZPT1-A6 ZP2-20UT ZP 16 J ZPG16J-7A-X2 8 8 8 9 ZPT2-7A-X2 ZP2-16J ZP B25 J ZPGB25J-7A-X2 14 15 15 18 ZP2-B25J ZPT3-7A-X2 ZP B30 J ZPGB30J-7A-X2 18 19 19 25 ZP2-B30J ZP3P 20 JT2 SF ZP3PG20JT2SF-7A-X2 21 ZP3P-20JT2SF-W ZP3PA-T1JT-7A-X2 ZP3P 20 JT2 SF M ZP3PG20JT2SF-M-7A-X2 21 ZP3P-20JT2SF-WM ZP3P 32 JT2 SF ZP3PG32JT2SF
Speed Controller for Low Speed Operation Series AS-FM/AS-M/ASD-FM In-line Type Dual Type In-line and dual types newly introduced!
No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -74No.PS-OMV0003CN-G No.
900 0.3 MK(2) 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 RS Q G 600 600 0 500 100 200 300 400 RS H A 63 Lateral load F [N] 500 500 50 400 400 RZQ RS1H50, 63, 80 300 300 1.0 RS1H80 MI W S RS1H50 200 200 RS1H63 0.9 Operating pressure P [MPa] 0.8 100 100 CEP1 0.7 10 20 30 40 10 20 30 40 0 0 0.6 CE1 Transfer speed [m/min] =
REC RSH20, 32 Graph (1) Graph (2) 1.0 CX RSH20 RSH32 0.9 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 Operating pressure P [MPa] CY 0.8 1300 1300 80 0.7 1200 1200 MQQ M 0.6 1100 1100 0.5 RHC 1000 1000 0.4 900 900 0.3 MK(2) 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 RS Q G 600 600 0 500 100 200 300 400 RS H A 63 Lateral
Vacuum regulator 13-14-2 Series IRV 13-14-3 Controls the vacuum pressure in accordance with external electric signals.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ There are other applicable auto switches other than the listed above. For details, refer to page 1197. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.
8.5 13 12.7 2-2.6 (For manifold mounting) 28.1 [35.1] (Light/surge voltage suppressor) 2-2.6 (For mounting) + 14.5 3 23 20 2.3 55.6 [57.8] 12.7 28.1 [35.1] 8 9 M5 x 0.8 (P, R port) 23 7 (Bracket) R P 11 11.5 1.4 (PE port) L plug connector (L): SYJ52-L-M5 (-F) M plug connector (M): SYJ52-M-M5 (-F) DIN terminal (D): SYJ52-D-M5 (-F) M8 connector (M0): SYJ52-W0-M5 (-F) Applicable cable O.D.
GH64 150 kPa (100 kPa200 kPa) 80 kPa220 kPaOFF (67 ) ISA3-F ISA3-G ISA3-H 1 m 1 m 1 m ON [mm] ON [mm] ON [mm] [kPa] [kPa] [kPa] 3 m 3 m 3 m ON [mm] ON [mm] ON [mm] [kPa] [kPa] [kPa] 5 m 5 m 5 m ON [mm] ON [mm] ON [mm] [kPa] [kPa] [kPa] -18No.PS-OMT0001CN-E 2 ON OUT 10090%0%() (0.1 mm0.09 mm0 mm) 1.5 F42.5 GH64 200 kPa 90% -ISA3-F ISA3-G ISA3-H 1 m 1 m 1 m [sec] [sec] [sec] [mm] [mm
(Example) Nil Lead wire length 0.5 m 3 m L 5 m Z None N Applicable for the connector type (D-C) only. Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-A73(C)(H)/A80C Solid state switch: Manufactured upon receipt of order as standard.