Valve: None; Stop Valve: None, Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
.: 10), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1T (12VDC; Faston Terminal), Other Options: B (NPT Thread), Bracket: XB (w/Bracket)
.: 15), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1T (12VDC; Faston Terminal), Other Options: B (NPT Thread), Bracket: XB (w/Bracket)
.: 10), Voltage/Electrical Entry: Z (Other Voltages and Electrical Options), Other Voltages and Electrical Options: 1T (12VDC; Faston Terminal), Other Options: B (NPT Thread), Bracket: XB (w/Bracket)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: P (Stop Valve), Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature
Series: 25A-PF3W5, Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min
Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
D Rz 12.5 * For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 Chamfered area for female thread 1. Conforming to ISO 16030 (air pressure fluid dynamics connection ports and stud For R, NPT, G Thread (Face seal type) ends), the chamfered dimensions shown in the table below are recommended.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.
tighten the threaded portion by hand, then use a proper wrench, which could be Rz 12.5 suitable for the width across flats of the hexagon body, to tighten it further at a wrench For Uni thread, Rz 12.5 is necessary for sealing at the chamfered part. 45 tightening angle shown in the table below.