Search Results "RDLQB63TN-100-F-M9NSAPC"

Thread type Voltage Rc G NPT Nil F N 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Port size Please consult with SMC regarding other voltages.

A F u Pilot solenoid valve SF4--23 (Refer to the table below.)

Series ZSE60F/ISE60 Confirmation of atmospheric pressure of load lock Special fitting types are used in semiconductor production equipment (metal gasket seal fittings) Leak rate: 1 x 10 -10Pa. m3/s ZSE/ ISE60(F)-A2 ZSE/ ISE60(F)-B2 URJ 1/ 4 TSJ 1/ 4 ZSE50F ISE50 ZSE60F ISE60 Model Standard thread type Special fittings for the semiconductor industry (metal gasket seal fittings) Variations

20 0.01 CY1H 100 400 250 0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Piston speed [mm/s] CY1F M2 M1, M3 [Graph 13] Allowable moment [Graph 11] Allowable moment CYP 200 200 100 100 Moment M1, M3 [Nm] Moment M2 [Nm] D CY1S25-Z CY1S25-Z E F D10 10 -X 5 5 100 400 250 100 400 350 Technical Data Piston speed [mm/s] Piston speed [mm/s] 1495 CY1S Series Calculation of Guide Load Factor Calculation

25 Tubing T, TU P. 26 Floating Joint/Stainless Steel Type JS P. 27 Features 2 Stainless Steel Cylinder Series CJ5-S 10, 16 How to Order Bore size Standard stroke (mm) 10 16 10 16 10mm 16mm 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Mounting B L F D Basic type Axial foot type Front flange type Double clevis type CJ5 L 16 S R 60 Without Auto Switch CDJ5 L

T n t Operating conditions Impact mass Collision speed Dropping height Angular speed Unit kg m/s m rad/s m N Nm cycle/min C m 2 1 2 E1 Kinetic energy F S E2 Thrust energy E Distance between rotational center and impact point Thrust Torque Operating frequency Ambient temperature Friction coefficient E1 + E2 Absorbed energy Note 2) E 2 2 Me Equivalent mass m F n t = 5 kg = 0.5 m/s =

Switch 100 kPa 0 100 kPa 500 kPa 1 MPa Pressure range 100 kPa 100 kPa For vacuum/ low pressure ZSE30 101 kPa 101 kPa 1 MPa 0 For positive pressure ISE30 100 kPa (0.1 MPa) 1 MPa Rated pressure range of switch Regulating pressure range of switch 16-2-14

To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.

65 41 A 97 61 a 2 2 STX 34 22 " 66 42 B 98 62 b 3 3 ETX 35 23 # 67 43 C 99 63 c 4 4 EOT 36 24 $ 68 44 D 100 64 d 5 5 ENQ 37 25 % 69 45 E 101 65 e 6 6 ACK 38 26 & 70 46 F 102 66 f 7 7 BEL 39 27 ' 71 47 G 103 67 g 8 8 BS 40 28 ( 72 48 H 104 68 h 9 9 HT 41 29 ) 73 49 I 105 69 i 10 0A LF 42 2A * 74 4A J 106 6A j 11 0B VT 43 2B + 75 4B K 107 6B k 12 0C FF 44 2C , 76 4C L 108 6C l 13 0D CR 45 2D

Shock Absorber Specifications Piston Speed Bore sizes (mm) 16 to 63 RB 1007 RB 1412 RB 2015 RB 0806 Model Without stroke adjusting unit 100 to 1000mm/s Max. energy absorption (J) A unit 100 to 1000mm/s Note 1) 5.9 19.6 58.8 2.9 L unit Stroke adjusting unit Stroke absorption (mm) 100 to 1500mm/s Note 2) 7 12 15 6 Max. impact speed (mm/s) Note 1) The air cushion capacity will be reduced when

ON/OFF / / 2 3 3 2 1 2 / -20- 3.3. [] LEC LEC / P.32 5.3 <> NPNPNP LEFS16A-100 NPN <> INPIN []INP ON ON INP ON OFF -21- <> No.1 01 a b c d e f g h i j k a ABSINC No. 1 2 mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 ABS 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 ABS 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 ABS()/ / INC()// b c d e f 00 g h i 100%DC24V 250% j 12

Movement MOD Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position 0 1: Absolute 100 10 3000 3000 0 0 0 100 0 0 0.50 1 1: Absolute 100 100 3000 3000 0 0 0 100 0 0 0.50 2 1: Absolute 100 200 3000 3000 0 0 0 100 0 0 0.50 Note) The step data input range changes depending on the actuator model.

Nil C M 40 50 63 80 100 40 mm 50 mm 63 mm 80 mm 100 mm Standard stroke Refer to Standard Stroke on page 10-3-13. D Double acting Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.

Nil C M 40 50 63 80 100 40 mm 50 mm 63 mm 80 mm 100 mm Standard stroke Refer to Standard Stroke on page 10-3-13. D Double acting Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

(2.8C) (17 m 3/h) (25 m 3/h) (43 m 3/h) (70 m 3/h) (100 m 3/h) (120 m 3/h) 11 SCFM 16 SCFM 26 SCFM 43 SCFM 62 SCFM 80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110 m 3/h) (147 m 3/h) 100psig (0.7MPa) 100 F (37.8C) 100 F (37.8C) 115V 60Hz

200 (Example) Clamp F: Pressing force (N) l Static torque calculation Ts = F x l (Nm) Shaft center Note) Effective torque values are representative values and not to be considered as guaranteed values.

16 16 0.2 0.05 0.1 0.2 0.1 0.05 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.

In order to actuate multiple cylinders at once, use a pressure regulator that can handle a large air flow volume and also consider installing a surge tank. 20Data 10-12-47 5 Stroke Reading Cylinder with Brake Series CE2 40, 50, 63, 80, 100 How to Order CE2 40 100 B Y7BW Mounting style Number of auto switches B L F G C D T Basic style Foot style Rod side flange style Head side flange style

VCKK1209-02F VCKK1008-02F VCKK1075-02F VCKK0806-02F VCKK0604-02F Symbol F G H J K Part no.