Refer to pages starting with 181 for mounting. 95 95 100 8(4)-6.2 B () () (170) 110 20 95 95 A () () (150) A B 100 200 300 400 Stroke Model LG1H212NA-100-F LG1H212NA-200-F LG1H212NA-300-F LG1H212NA-400-F 60 160 260 80 180 280 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)
100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)
L1 E1 R1 U1 A1 U1 R1 A MM NDH10 NZ MM NDH10 NX NX E1 L1 30 40 50 60 60 20 22 28 40 40 12 12.5 16.5 23.5 23.5 16 19 24 34 34 32 40 50, 63 80 100 32 40 50, 63 80 100 14 19 24 26 26 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 M10x1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20
System setting items (example using compact Wireless Base EXW1-BMJA#) Parameter Set value Initial value I/O mapping Manual Manual Diagnostic allocation Advanced Advanced DA refresh time (sec) *1 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 / 30 / 60 s 1 s Output Action of Upper Communication Clear / Hold / Individual Clear Time of Wireless Communication 20 / 40 / 100/ 200 / 500 / 1,000 / 2,000 / 5,000
D-Y7GL Motor model Compatible driver model Power supply voltage (VAC) Motor output (W) + Brown lead wire MSD021P1E MSM021P1A Matsushita Electric Industrial Co., Ltd. 100/115 Main circuit of switch MSM022P1A 200 Output Black lead wire MSD023P1E 200/230 MR-C20A1 100/115 Mitsubishi Electric Corporation HC-PQ23 200 MR-C20A 200/230 SGDE-02BP 100/115 200 SGME-02BF12 Yaskawa Electric Corporation
VAC, 220 VAC, 230 VAC (50/60 Hz) Allowable voltage fluctuation 10% of rated voltage VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil insulation type Class H VX3 Power consumption (W) 50/60 Hz VCS2: 4.9/4.1, VCS3: 7.7/6.6, VCS4: 10.5/9.3 Inrush VCS2: 22/19,
[Option] Electrical entry D: DIN terminal DO : DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) Rated voltage Valve option Rated voltage Nil V Y W E DC AC CE-compliant 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz For the connector part number, refer to page
Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
Rated voltage G: Grommet (Lead wire length: 300 mm) D: DIN terminal DO: DIN terminal H: Grommet (Lead wire length: 600 mm) 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 240 VAC, Hz Other (Without connector) 50 60 50 60 50 60 4 5 6 7 50 60 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
(Values at the initial period) VT325-C VT325-G JIS Symbol Solenoid Specifications Grommet, Conduit, DIN terminal, Conduit terminal 100, 200 VAC, 50/60 Hz, 24 VDC 15 to +10% of rated voltage 75 VA 60 VA 27 VA 17 VA 12 W Electrical entry Coil rated voltage Allowable voltage fluctuation 50 Hz 60 Hz 50 Hz 60 Hz Inrush AC Apparent power (3) Holding DC Power consumption (3) Note 3) At rated voltage
Note 2) DIN is applicble to VQZ 200 and 300. Note 3) Electrical entry of pilot valve for VQZ100(L and M) is opposite side of valve body part number.
2 Slide screw 0.05 Without motor brake Series LXF 30 Direct acting guide Ball screw 0.03 80 3 100 0.05 Slide screw 200 2 Guide rod type Series LXP 200 3 0.05 Slide screw 100 4 Without motor brake 30 Ball screw 0.03 6 80 Ball bushing guide 100 Slide screw 0.05 200 2 200 3 Slide screw 0.05 100 4 With motor brake 30 Ball screw 0.03 5 80 100 Slide screw 0.05 200 3 Slide table
2 0.05 Slide screw Without motor brake Series LXF 30 Direct acting guide 0.03 Ball screw 80 3 100 0.05 Slide screw 200 2 Guide rod type Series LXP 200 3 0.05 Slide screw 100 4 Without motor brake 30 0.03 Ball screw 6 80 Ball bushing guide 100 0.05 Slide screw 200 2 200 3 0.05 Slide screw 100 4 With motor brake 30 0.03 Ball screw 5 80 100 0.05 Slide screw 200 3 Slide table
IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 950
100 60 60 Air consumption Air consumption 150 50 50 75 40 40 100 50 30 30 20 20 50 25 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 1.0 2.0 3.0 4.0 5.0 6.0 Supply pressure [MPa] Supply pressure [MPa] Flow rate Characteristics Flow rate characteristics Supply pressure: 0.4MPa Supply pressure: 0.4MPa 100 90 100 90 Vacuum pressure [kPa] Vacuum pressure [kPa] 80 80 70 70 60 60 50 50 40 40 30 30 20 20
70 158 124 142 63 M10 x 1.5 9 M10 x 1.5 WA WB Bore size (mm) VB X XA XB XC XL YY YL Z st25 25
(mm) AS5000-02 AS420-02 AS4000-03 400 200 200 100 0 0 400 800 CS1 125 MB 100 600 300 Stroke (mm) AS5000-02 AS420-02 200 400 AS4000-04 200 100 0 0 Solenoid valve Silencer Tubing Speed controller Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end (mm/s) Speed at the end (mm/s) Applicable
Possible to install auto switches Series Variations Standard stroke (mm) Rod end configuration Applicable auto switch Action Type Bore size (mm) 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 25 Single rod 32 Reed switch D-A7 D-A8 (2-color) D-A79W Double acting 40 50 Double rod Male thread, Female thread 63 Solid state switch D-A7 D-J79 (2-color) D-F7W D-J79W 25 32 Spring return
PT/PF thread model I.D.4mm or more, O.o.l0mm or more, length 5m or less NPT thread model 1.0.3/16" or more, 0 .D.3/8" or more, OFluSh piping on the secondary side of AMH . length 200" or less Normally Open: ~ Open and close pipe line before operation to ensure proper connection sealing.
CN1IF (CONT) 19 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SW OFF RWw(n+1)b0 ON(1) (LEC) (LEC)(LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB ) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.CN2TB/PC () 20 - .CN4 6.1 1 EMG+ EMG 2 EMGEMG 3 24V 5 4 3 2 1 () 4 0V 5 FG FG (LEC)(0V)