Model Piping method Rc 1/4 thread Gasket piping Rc 1/4 thread Gasket piping Micro switch type Min. applicable load IS3000-02 IS3100 IS3010-02 IS3110 Standard 5 VDC 160 mA Micro load 5 VDC 1 mA Easy electrical wiring Wide space for wiring. Fixed wiring possible with G 1/2 connector.

IS3000-02 IS3100 IS3010-02 IS3110 Standard 5 VDC 160 mA Z I SE3 Micro load 5 VDC 1 mA PS Easy electrical wiring Wide space for wiring. Fixed wiring possible with G 1/2 connector.

12 to 24 VDC Load Load DC () (Blue) DC () (Blue) ZSE40(F) ISE40--30(L)-(M) With auto shift input ZSE40(F) ISE40--70(L)-(M) With auto shift input DC (+) (Brown) Auto shift input (Gray) OUT1 (Black) OUT2 (White) DC (+) (Brown) Auto shift input (Gray) 1.2 k 1.2 k Load 6.8 k 6.8 k Main circuit Main circuit Load OUT1 (Black) OUT2 (White) 12 to 24 VDC 12 to 24 VDC Load Load DC () (Blue) DC ()

load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge voltage.

The power supply voltage for control and input is below 19 VDC. (When diagnostic parameter is enabled) Red ON PWR 9 Unit connector (Plug) Connector for signals and power supplies to adjacent units. 10 Connector (PORT1) Connector for the fieldbus communication cable. The power supply voltage for output is below 19 VDC.

Power supply for Control/Input 24 VDC Class 2, 2 A These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".

Power supply for output devices (24 VDC) 1 2 1 2 Power supply for output devices (0 V) 5 [Power supply for sensor (24 VDC)] 3 If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product regularly for proper operation.

-Terminal A (shorter side): Connect the 24 VDC wire. -Terminal B (longer side): Connect the 0V wire. (3) Solder the wires and bend and clamp the crimping area of terminal B with pliers.

-Terminal A (shorter side): Connect the 24 VDC wire. -Terminal B (longer side): Connect the 0V wire. (3) Solder the wires and bend and clamp the crimping area of terminal B with pliers.

Table 3-1 Amount of heat radiation and required ventilation Required amount of ventilation [m3/min] Model No.

Step motor (servo/24 VDC) and servo motor (24 VDC) specifications with the following model number are not compliant with UL Standards: Controller/Driver type: Without controller/driver (Nil). Individual actuators are not certified as UL Standards compliant products. 7.

(Tightening torque: 0.6 Nm) Specifications Power for DeviceNet: 11 to 25 VDC, 0.1 A or less Power for input: 24 VDC 20%, 1 A or less (Depending on number of connecting sensors and specifications) Power for valve: 24 VDC +10%/-5%, 2 A or less (Depending on number of solenoid valve station and specifications) Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less

load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge voltage.

Output (OUT2) indicator (Red) Lead wire with connector Internal Circuits and Wiring Examples ZSE10(F)/ISE10 Output specifications A B NPN (2 outputs) PNP (2 outputs) Brown DC (+) Brown DC (+) Load Black OUT1 Black OUT1 Main circuit Main circuit Load + Load + 12 to 24 VDC 12 to 24 VDC White OUT2 White OUT2 Load FUNC FUNC Blue DC () Blue DC () Max. 28 V, 80 mA Residual voltage 2 V or less

(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Power supply (0 VDC) 3 6 4 4 3 20 m or less total extension per branch Branch cable length Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof.

NOTE 24 VDC, Class 2, 0.06 A 24 VDC, Class 2, 0.12 A Power supply Rated input current 8 mA When conformity to UL is necessary the SI unit must be used with a UL1310 Class 2 power supply. The product is a UL approved product only if it has a mark on the body.

Response time 3 1 s/2 s Analogue output Voltage output Output voltage: 1 to 5 V, Output impedance: 1 k Current output Output current: 4 to 20 mA Max. load impedance: 300 for 12 VDC, 600 for 24 VDC. -67No.PF-OMN0012-H Model PF3W30# Hysteresis Variable External input Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer Input/Output Input for copy mode 2-screen

at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Voltage 2 2 4 4 15 10 250 VAC 1.5 1.5 3 3 15 10 8 VDC 1.5 2.5 3 5 15 15 14 VDC 1.5 2.5 3 5 15 10 30 VDC 1.5 2.5 3 5 6 5 125 VDC 0.3 0.05 0.3 0.05 0.5 0.05 250 VDC 0.2 0.03 0.2 0.03 0.25 125 VAC 15 15 15 15 6 0.5 0.25 0.03 10 10 15 10 5 0.05 0.03 JIS Symbol

DIN rail mount type and box mount types are available. 587 PC Wiring System e-con Type Series PCW-EC Common Specifications Rated voltage 24 VDC Power supply line 2 A Rated current Communication line 0.3 A Insulation resistance 5 M or more at 100 VDC Withstand voltage 500 VAC Impact resistance 500 m/s2 Screw tightening torque (Phillips head screwdriver/flat head screwdriver) 0.4 to 0.6 Nm/