SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-32-17-M5"

6 Mounting screw (Size: M5) 2 !7 Cable tie holder 5 !8 Binding band 4 !9 Reusable band 1 (170) @0 Sealant tape PTFE 1 @1 DI control solenoid valve extension cable 1 1 The product should be replaced when it can no longer preserve the electrical conductivity set value.

RUN 15 Starting PRO-NO BIT 1 17 17 Pro-no. bit1 The terminal that designates the program to be executed. Can designate 8 types of programs with a total of 3 bits. (Set by the binary system.)

RUN (15) Starting PRO-NO BIT 1 17 Control input (17) The terminal which designates the program to be executed. Can designate 8 types of programs with a total of 3 bits.

Bore size 25 32 40 25 mm 32 mm 40 mm Number of auto switches Nil S n 2 pcs. 1 pc. n pcs. Port thread type Bore size Symbol Nil TN TF Type Rc NPT G 25, 32, 40 Auto switch Nil Without auto switch (Built-in magnet) Refer to the table below for the applicable auto switch model.

) 17) 40 1418) (14~18) 51 1276 1375 () (1) 1,3 (2) (1) 1,3 () 20 335 7122 670 752 (3) (3) (2) IDF100150F 6-3 6 2 IDX-OM-U021 6 IDF125F-30K16K () (10,2m) ) (10 ( 4 () () JIS 65A 10K 4x (K16K) 2m) 20 4x JIS 65A 10K 25 25 (10,0.7m) 78 9351 267 18 8x19 4x19 A A A 140 1130 140 1120 655 K 18 K 75 K16K (17) 64 (K16K) 17) JIS 65A 10K JIS 65A 10K 40 51 1276 1418) (14~

Class 1 Turbine Oil (with no additive), ISO VG32 Classification of viscosity (cst) (40C) Viscosity according to ISO Grade 32 Turbine oil P-32 Idemitsu Kosan Co.,Ltd. Turbine oil 32 Nippon Mitsubishi Oil Corp. Cosmo turbine 32 Cosmo Oil Co.,Ltd. Kyodo turbine 32 Japan Energy Corp. Turbine oil 32 Kygnus Oil Co. Stork turbine 32 Kyushu Oil Co.

* flange: MQR8-F (for MQRF8-M5) * flange: MQR12-F (for MQRF12-M5) * o 55 * o 45 * o 41 * o 50 * 4-4.5 mounting hole * 4-8 counter bore 5.5 4.5 mounting hole +0.05 4.1 depth10 54h8 24 x M5 x 0.8 10 counter bore depth1.5 30h8 (10 from end) 49h8 0 -0.033 25h8 16-M5 x 0.8 10 counter bore depth1.5 0 0.033 3 120 140 17 *7 (10 from end) 3 (87) 1 2 3 4 5 6 7 8 9 10 11 12 1 2 31 9 8.2 x 11 = 90.2

PV SV 32. Select the contact input signal 1 type with [] key or [] key, and press [SEL] key to enter. Table 5.21-17 Setting of contact input signal 1 type Set value Explanation Initial value (Default setting) Setting/checking is not available when contact input signal 1 setting is OFF.

Indication Item Setting, selection and display 1 ASCII code (1) Protocol Communication format Binary data 1 EIA RS-485 (2) Type Standard EIA RS-232C 9600 bps (3) Baud Rate Communication speed 1 19200 bps (4) Slave Address Slave address 1 to 32 Select from 1 to 32 1 1 1 Disabled (5) DIO Run/Stop 2 Run/stop by contact input Enabled Displays the communication status (6) Communication Status

x 0.5 SS3Y1-31 M5 x 0.8 M3 x 0.5 SS3Y1-S41 M5 x 0.8 M5 x 0.8 Note) Value at manifold base mounted How to Order Valve Manifold Assembly Example Stations3 2 1 Valve (N.C.)

Indication Item Setting, selection and display 1 ASCII code (1) Protocol Communication format Binary data 1 EIA RS-485 (2) Type Standard EIA RS-232C 9600 bps (3) Baud Rate Communication speed 1 19200 bps (4) Slave Address Slave address 1 to 32 Select from 1 to 32 1 1 1 Disabled (5) DIO Run/Stop 2 Run/stop by contact input Enabled Displays the communication status (6) Communication Status

The connection size is M5. Applicable crimped terminal width: 9.5mm or less [Wiring procedure] 1. Remove the front panel of the product. When lifting the front panel, be sure to hold the handle. 2.2 Installation 2 7 IDF100F~150F-W IDX-OM-M051 Air Dryer 2. Transportation and installation 2.

17 20 20 15 15 2 x M6 thread depth 11 (for YA type) 2 x M6 thread depth 11 (for IA type) 35 15 18 2 x M6 thread depth 11 (for IA type) 2 x M6 thread depth 11 (for YA type) 20 20 20 20 57 40 17 17 A 19.5 0.2 0.5 25 15 45 45 60 60 Material: Cast iron Unit: mm Material: Cast iron Part no.

HRL Series 5.4 Description of the Screen 5-63 HRX-OM-Y098 Chapter 5 Display and Setting of Various Functions Table 5.4-32 List of maintenance reminders 1 Maintenance No.

) N01 NPT1/8 (M5) A1 A C4H 4mm5/32 inch C6H 6mm A2 B NH7 1/4 inch N7H A3 C C4L 4mm5/32 inch C6L 6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L 2 ) C ZS-38-A3 (M35 L 2 ) ZS-27-C (M38 L 2 ) + ZS-27-D (M38 L 2 ) ZS-38-3L 3

J 30 41 50 T M4 X 0.7 M4 X 0.7 M5 X 0.8 K 27 40 54 S 32 44 60 AF20 AF30 AF40 Auto Drain mm Dimensions Mounting Bracket Kit (Optional) AF30P-050AS-X480 AF40P-050AS-X480 Model Port Size D 158 194 M 6.5 8.5 R 35 47 N 8 10.5 Q 2.3 2.3 L 23 26 P 53 70 W 34.5 41 A NPT 3/8 NPT 1/2 C 53 70 F 53 70 E 14 18 G 57 73 H 16 17 J 41 50 T M4 X 0.7 M5 X 0.8 K 40 54 S 44 60 AF30 AF40 4 Series AF20~40 Filter

PV SV 32. Select the contact input signal 1 type with [] key or [] key, and press [SEL] key to enter. Table 5.21-17 Setting of contact input signal 1 type Set value Explanation Default Setting/checking is not available when contact input signal 1 setting is OFF.

x 0.8 (10-32 nominal) M3 x 0.5 Port size Top ports M3 x 0.5 M5 x 0.8 (10-32 nominal) Deflection accuracy 0.03mm or less (0.0012") 2.