How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
32.5 38.5 35 38 34 27 29 26.5 40 35 36 42 38.5 44 41.5 37.5 30.5 32.5 30 50 41 42 48 44.5 47.5 50 43.5 36.5 38.5 36 63 47.5 48.5 54.5 51 54 50 56.5 40 42 39.5 12 Series RZQ Auto Switch Mounting Follow the procedures below to mount auto switches.
For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire
Cable connector (option) 63 (S type: 39) L1=101 (S type: 77) Part name Part number Suited cable outer diameter Resin-made cable clamp unit (A) P368010-26 7 to 9 M8 x 1.25 Resin-made cable clamp unit (B) P368010-27 9 to 11 M8 x 1.25 Actuator main shaft Actuator main shaft Side mounting with the fork lever assembly M Side mounting with the fork lever assembly S Cable connector G1/2 Exploded
Nylon Urethane L1 L2 M 1 4 1 4 3 8 3 8 3 8 KCE04-02 KCE06-02 KCE08-03 KCE10-03 KCE12-03 2.6 32 36 42 79 105 2.6 6.8 16.2 25.6 35.4 M12 1 M14 1 M16 1 M20 1 M22 1 40.5 42.7 49.4 53.9 56.1 14 17 19 24 27 17 17 19 22 24 14.7 14.7 15 14.2 13.7 13 15 17 21 23 18 19 21.5 24 25.5 6.8 13.1 20.4 30.4 Straight: KCH Applicable tube O.D.
High Vacuum Angle/In-line Valve Dimensions XMA/Angle type C D L2 (KF flange) Fn Fd Fc C (Fc) L1 (K flange) (CF flange) H B G A A (mm) Model A 103 113 158 170 196 235 B 38 48 66 79 100 117 C 1 1 2 2 3 3 D 30 40 55 75 87 114 Fn 95 110 Fd 34 70 114 Fc 17 26 41 52 70 83 G 40 39 63 68 69 96 H P.C.D L1 6-4.4 6-6.6 8-8.4 L2 XMA-16 XMA-25 XMA-40 XMA-50 XMA-63 XMA-80 40 50 65 70 88 90 P.C.D 27
Thread ZPT 10/13/16 F-B5 (Without Buffer/Female Thread) ZPT 20/25/30 F-B 5/8/01 (Without Buffer/Female Thread) Width across flats P N M5 x 0.8 NL Width across flats 8 5 Y Width across flats 12 F Width across flats 10 Width across flats 3 F Width across flats 2 D 3 D C C 2 2 A A B B Dimensions A Dimensions A (mm) (mm) B C D F Y B C D F N NL P Model Model ZPT10F-B5 ZPT20F-B5 10 12 10 12.5 27
Refer to "LECSC2-T Operation Manual (Simplified Edition)", section 5.7 for how to set the Point table. -28- Recommended Parameter Values [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Series Lead symbol H A B H A B T Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para. Initial value Recommended value No.
N.C. 24 No.ZL3-OM00801-A 11. ,, 11.1 25 No.ZL3-OM00801-A 11.2 11.3 (V),0, Pmax () (P1 Q1 ) (Qmax) 0() , 1L ZL3H ,-90kPa ,4.0 ,Pmax Qmax , 26 No.ZL3-OM00801-A 12. 12.1 12.2 0 27 No.ZL3-OM00801-A 13.
(Refer to page 29) Then press button again to change the pressure while the display is flashing. *: ON/OFF point of the supply pilot valve and the set point of the input prohibited range of the supply pilot valve may be corrected by the autopreset function. 27 - NO.
ZQ-OM01601 // ZQ-ZSV 2 9 10 11 14 14 15 16 16 19 19 19 F0 21 F1 OUT1 22 F2 OUT2 24 F3 26 F4 27 F6 29 F11 30 F80 31 F81 32 F90 33 F96 35 F98 36 F99 38 39 42 43 44 50 51 51 1 - *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.
TQ1230001-OM107 ModelZPG16J-7A-X2 ModelZPG(B25,B30)J-7A-X2 (Suction cup formMultistage bellows type 2.5-Stage) (Suction cup formMultistage bellows type 3.5-Stage) Dimensions Model A B D E F G H ZPGB25J-7A-X2 25 26 27 10.2 32.5 48 52.5 ZPGB30J-7A-X2 30 33 32 13.8 38 54.5 59 Note1) D and (st) indicate the reference value during gripping at vacuum pressure: -85[kPa]. -13No.
Air supply .27 5-5. Piping .27 5-6. Operating environment .28 5-7. Lubrication .28 6. Maintenance or inspection .28 6-1. Maintenance or inspection .28 6-2. Replacement part .29 6-3. Maintenance .29 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Panel mount adapter (Model: ZS-27-C) Panel mount adapter + Front protective cover (Model: ZS-27-D) Troubleshooting Warning Error Indication This function is to display error location and content when a problem or an error occurs. Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result.
No.PS-OMM0006CN-E // ZSE40A(F) ISE40A 2 9 12 13 16 16 18 20 23 23 25 25 25 F0 27 F1 OUT1 28 F2 OUT2 31 F3 33 F4 34 F5 / 36 F6 38 F11 39 F80 40 F81 41 42 F90 42 F97 44 F98 46 F99 48 49 52 52 53 60 60 63 -1No.PS-OMM0006CN-E (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules
OFF ON SET2OUT1 ()[P_2][n_2]OUT2 SET2 1SET 2SETSET2 3(29)OFF ([SEt]) -23No.PS-OMV0003CN-G 23 P1L()P1H()WH1() dtH/dtL() (n1L n1H) 31 OUT2 -24No.PS-OMV0003CN-G SET3~5[F 0] [F] SET2 SET 3 ~5 FO F1 F99 ()[-] [F 0] 27 [M]MPa PNP ALL [F 1] OUT1 29 OFF ONOFF ISE700.500 MPa ISE710.800 MPa ISE700.050 MPa ISE710.080 MPa 0.00 sec.
No.PS-OMV0008CN-E / / ISE70G--L2 ISE75G--L2 ISE76G--L2 ISE77G--L2 ISE78G--L2 2 9 10 12 15 15 17 19 21 22 3 23 25 27 27 28 F0 30 F1 OUT1 32 F2 OUT2 35 F3 37 F4 38 F6 40 F10 41 F11 47 F14 Zero-cut 48 F80 49 F81 50 F90 52 F96 54 F98 55 F99 57 58 IO-Link 63 IO-Link 63 63 64 IO-Link 67 76 76 77 86 88 -1No.PS-OMV0008CN-E (ISO/IEC)(JIS) *1) *2) *1) ISO
W MY1B 20 mm 30 mm 50 mm 2 kg Calculation of Load Factor for Static Load 3 Calculation of Load Factor for Dynamic Moment 4 MY1M m1: Mass Equivalent load FE at impact MY1C 1 100 FE = 1.4a x x m x g = 1.4 x 300 x x 2 x 9.8 = 82.3 (N) m1 m1 max (from q of graph MY1B/m1) = 27 (kg) Load factor 1 = m1/m1 max = 2/27 = 0.07 M1E: Moment MY1H FE M1E max (from q of graph MY1B/M1 where 1.4a = 420
]: for nomal position Note 3) ( ): without sub-plate Note 4) Model No. for base mounted type without sub-plate is SYJA740. 1482 4/5 Port Air Operated Valve SYJA7000 Series Dimensions/Body Ported Dimensions/Base Mounted 01 02 2 position single: SYJA7120-01(-F) 2 position single: SYJA714060.1 28.3 34 8.5 M5 x 0.8 (Pilot port) 2 x 4.3 (For mounting) M5 x 0.8 (Pilot port) B A 13 1 3 B A 34 27
(mm) 8 2 2.5 4 5 6.5 M Black (B) H/DL L/LL Air Fluid KC 20C 0.9 Max. operating pressure (MPa) 40C 0.7 KK Recommended fittings Antistatic one-touch fittings: KA series Miniature fittings: M and MS series Note) Minimum bending radius (mm) 10 15 20 27 35 10 KK130 0 to 40C Operating temperature Max.