Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3

(A) 2 1 (P) 3 (R) VQZ200/300 Metal seal type Rubber seal type 4 3 2 1 4 3 2 1 N.C. N.C. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) 4 3 2 1 4 3 2 1 N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Parts list Material Part Numbers No.

Port size R 1/8 R 1/4 R 1/8 R 1/4 R 3/8 R 1/2 R 3/8 R 1/2 R 3/4 R 1/8 R 1/4 R 1/8 R 1/4 R 3/8 R 1/2 R 3/8 R 1/2 R 3/4 KK3P-01MS -02MS KK4P-01MS -02MS -03MS -04MS KK6P-03MS -04MS -06MS KK3S-01MS -02MS KK4S-01MS -02MS -03MS -04MS KK6S-03MS -04MS -06MS 1/8 1/8 1/4 1/4 1/2 1/2 Female thread type Female thread type Body size Port size Part no.

ALF400 ALT-9 1.17-11 Auto Feed Lube ALF400 to 900 Operating pressure range Tank and line pressure How to Order Auto Feed Lube ALF 40 02 0 Option Auto Feed Lube Port size Symbol Description Applicable model W/ bracket ALF400 to 600 B 02 03 04 06 10 12 14 20 4 1 Body size 8 3 AC 40 50 60 80 90 2 1 2 1 4 3 4 3 AV 1 1 2 1 1 1 2 2 1 4 1 AU 2 1 AF Thread Rc (PT) NPT G (PF) N F AR Note 1) Tank

Port size: Rc 1/8, 1/4 (NPT, G threads are not available.)

8, 1/4 1/8 40 87.6 71.8 21 M281 40 21 5 f37.5 57.5 f37.5 58.5 f37.5 58.5 AW30-D 1/4, 3/8 1/8 53 115.3 86.5 26.5 30 M381.5 55 26.5 3.5 f37.5 63 f37.5 64 f37.5 64 AW40-D 1/4, 3/8, 1/2 1/8 70 147.1 91.5 35.5 38.4 M421.5 80 35.5 0 f42.5 73 f42.5 73 f42.5 73 AW40-06-D 3/4 1/8 75 149.1 93 35.5 38.4 M421.5 80 35.5 0 42.5 73 42.5 73 42.5 73 AW60-D 3/4, 1 1/8 95 234.1 155 45 38.4 M621.5 30 45 0 42.5

Standard Specifications Model AFM20-D AFM30-D AFM40-D AFM40-06-D Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 Air Fluid -5 to 60 C (with no freezing) Ambient and fluid temperature Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Min. operating 0.15 MPa N.C. 0.1 MPa pressure of auto 0.1 MPa N.O.

Standard Specifications Model AFD20-D AFD30-D AFD40-D AFD40-06-D Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 Fluid Air -5 to 60 C (with no freezing) Ambient and fluid temperature Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Min. operating 0.15 MPa N.C. 0.1 MPa pressure of auto 0.1 MPa N.O.

8, 1/4 1/2 3/8, 1/2 0.25 (0.31) 0.43 (0.51) 0.66 (0.76) 0.74 (0.87) 0.77 (0.90) 1.50 (1.65) 1.50 (1.65) 1.55 (1.70) Note 1) With no freezing.

2 3/4 1 3/8 1/2 3/4 1 3/8 1/2 3/4 1 4.6 6.5 11.8 18.3 3.5 4.8 7.1 11.0 1.25 2.7 4.5 7.3 0.5 MPa 1.0 MPa 1.6 MPa ( ): Mass including the bracket Add the mass of an auto switch additionally.

2 37.5 57.5 37.5 58.5 37.5 58.5 AR30-D 1/8 53 86.5 30.5 26.5 26.5 3.5 37.5 63 37.5 64 37.5 64 AR40-D 1/8 70 91.5 35.5 35.5 35.5 42.5 73 42.5 73 42.5 73 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 M421.5 M381.5 AR40-06-D 1/8 75 93 35.5 35.5 35.5 42.5 73 42.5 73 42.5 73 AR50-D 1/8 90 125 43 45 45 42.5 82.5 42.5 82.5 42.5 82.5 AR60-D 1/8 95 155 45 45 45 42.5 82.5 42.5 82.5 42.5 82.5 3/4 M421.5 3/4, 1 1

Standard Specifications Model AWD20-D AWD30-D AWD40-D Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/4 Pressure gauge port size Note 1) 1/8 Air Fluid -5 to 60 oC (with no freezing) Ambient and fluid temperature Note 2) 1.5MPa Proof pressure 1.0MPa Max. operating pressure 0.05 to 0.85MPa Without auto drain Auto drain (N.C) 0.15 to 0.85MPa Set pressure range 0.1 to 0.85MPa Auto drain (N.O) 0.1 to

Standard Specifications AWM20-D AWM30-D AWM40-D Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/4 Pressure gauge port size Note 1) 1/8 Fluid Air Ambient and fluid temperature Note 2) -5 to 60 oC (with no freezing) Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto drain 0.05 to 0.85MPa Auto drain (N.C) 0.15 to 0.85MPa Set pressure range 0.1 to 0.85MPa Auto drain (N.O) 0.1 to

Type (Metal body) CE1 Air Flow/Effective Area AS220M-02 AS120M AS220M-01 CE2 Model R 1/4 Cylinder side M5 x 0.8 10-32 UNF NPT 1/8 NPT 1/4 R 1/8 Port size ML2B Rc 1/4 Rc 1/8 Tube side Air flow (l/min (ANR)) 38 7 12 Controlled flow Effective area (mm2) C J G5-S 0.6 0.1 0.2 Flow rate (l/min (ANR)) 420 105 280 Free flow Effective area (mm2) CV 6.5 1.6 4.3 Note) Supply pressure: 0.5 MPa, Temperature

Set pressure range [MPa] 0.1 to 1.7 Ambient and fluid temperature [C] 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Model AR20-B AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Port size 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 r BG AR B B X430 30 03 BG q 30 AR

The compressed air quality class on the inlet side is [7:9:4]. -8- 4. How to Order AF D 30 03 B Description Symbol Body size 20 30 40 50 60 Nil Rc Thread type N NPT F G 01 1/8 02 1/4 03 3/8 Port size 04 1/2 06 3/4 10 1 Nil Without mounting option a Mounting B With bracket Option Nil Without auto drain b Float type C N.C.

Display resolution Output mode OUT1 OUT1 Hysteresis mode 1/10 of P_1 (n_1) 1/10 of P_2 (n_2) Window comparator mode 1/4 of P1H P1L (n1H n1L) 1/4 of P2H P2L (n2H n2L) Error output 1/7 of rated maximum pressure rated minimum pressure Switch output off -45No.PS-OMV0009-E During an error output or when the switch output setting is OFF, the pressure value meter at the atmospheric pressure

Standard Specifications Model AL20-D AL30-D AL40-D AL40-06-D AL50-D AL60-D Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Fluid Air -5 to 60 oC (with no freezing) Ambient and fluid temperature 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure Port size 1/4: 30 L/min(ANR) Port size 3/8: 40 L/min(ANR) Port size 1/2: 50 L/min(ANR) 50 L/min(ANR) 190 L/min(ANR) 220 L/min(ANR) Min.

Display resolution Output mode OUT1 OUT1 Hysteresis mode 1/10 of P_1 (n_1) 1/10 of P_2 (n_2) Window comparator mode 1/4 of P1H P1L (n1H n1L) 1/4 of P2H P2L (n2H n2L) Error output 1/7 of rated maximum pressure rated minimum pressure Switch output off -42No.PS-OMV0004-H During an error output or when the switch output setting is OFF, the pressure value meter at the atmospheric pressure

HOW TO ORDER AW 30 03 BE 1 B 1 3 4 5 2 1 Symbol Description Body size 20 30 40 60 Nil Rc N NPT Thread type 2 F G 01 1/8 02 1/4 03 3/8 Port size 3 04 1/2 06 3/4 10 1 Nil Without mounting option B With bracket a Mounting H With set nut for panel mounting Nil Without auto drain b Float type auto Option C With float type auto drain (N.C.) drain 4 D With float type auto drain (N.O.)