side Voltage 3 110VDC 5 24VDC Manual override B Locking type (Tool required) Thread type N NPT Thread size 02 1/4 Specifications 5-way solenoid valve configuration (for Double acting actuator ) Fluid Air or inert gas Reverse function Normal function Working pressure range 21.8psi to 130psi (0.15 to 0.9 MPa) D-TYPE B-TYPE Ambient & Fluid Temperature 14F to 140F (10C to +60C) Lubrication Not
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, AS 1/4INCH (MISC./OTHER), AIRLINE EQUIPMENT, AS FLOW CONTROL, DX, AS 1/4INCH (MISC./OTHER), 0.11693 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, AS 1/4INCH STANDARD (PT), AIRLINE EQUIPMENT, AS FLOW CONTROL, DB, AS 1/4INCH STANDARD (PT), 0.18005 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, AS 1/4INCH STANDARD (PT), AIRLINE EQUIPMENT, AS FLOW CONTROL, DB, AS 1/4INCH STANDARD (PT), 0.16534 lb
Model: 22, Port Size: 2 (Rc1/4), Thread Type: N (NPT), Base/Seal Material: S (Stainless Steel, NBR Seal), Suffix: Standard, Number of Manifolds: 2 Stations
Model: 22, Port Size: 2 (Rc1/4), Thread Type: Rc, Base/Seal Material: S (Stainless Steel, NBR Seal), Suffix: Standard, Number of Manifolds: 2 Stations
Size: No.2, Port Size: 1/4, Manifold Base: Individual Pressure SUP, Stations: 2 Stations
Size: No.2, Port Size: 1/4, Manifold Base: Common Pressure, Stations: 2 Stations
Size: No.1, Port Size: 1/8, Manifold Base: Individual Pressure SUP, Stations: 2 Stations
Size: No.1, Port Size: 1/4, Manifold Base: Common Pressure, Stations: 2 Stations
Size: No.1, Port Size: 1/8, Manifold Base: Common Pressure, Stations: 2 Stations
Flow Range: 1~10l/min, Thread: Rc, Port Size: Port Size 1/4, Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 5~50 l/min, Thread: Rc, Port Size: Port Size 1/4, Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Applications: 0.05~0.20MPa Operating Pressure Range, Thread: None, Port Size: 1/4, Accessory: w/o Accessory, Option: 1000cm3 Tank
Applications: 0.05~0.70MPa Operating Pressure Range, Thread: None, Port Size: 1/4, Accessory: w/o Accessory, Option: 1000cm3 Tank
Size: 3/8, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: None, Option 1: 0.02~0.2MPa Setting, Option 2: -
Size: 1/2, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: None, Option 1: 0.02~0.2MPa Setting, Option 2: -
Size: 1/8, Reverse Flow: Regulator w/Backflow Mechanism, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: None, Option 1: 0.02~0.2MPa Setting, Option 2: -
Size: 20, Backflow Function: K (Backflow Function), Thread: Rc, Port Size: 02 (1/4), Accessory: None, Specifications: 1 (0.005 to 0.2 MPa Setting)
Size: 30, Backflow Function: K (Backflow Function), Thread: Rc, Port Size: 02 (1/4), Accessory: None, Specifications: 1 (0.005 to 0.2 MPa Setting)