SMC Corporation of America
Elite Part Number Search
Search Results "ISE10-M5-E-PR"

Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: WO (M8 Connector w/o Cable), Surge Suppressor: None, Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Function: 4 (3 Position Exhaust Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: WO (M8 Connector w/o Cable), Surge Suppressor: None, Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Function: 5 (3 Position Pressure Center), Piping: 2 (Body Ported), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Function: 5 (3 Position Pressure Center), Piping: 2 (Body Ported), Exhaust: 3 (Common), Specifications: T (Power Saver), Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Manually Operated), Port Size: M5 (Body Ported M5X0.8)

Fluid: 0 (Air), Body, Port Size, Orifice: A [Resin (PPS); M5; 1.0], Voltage, Electrical Entry: E (230 VAC; Grommet), Option: C (M6 Thread)

Connector width9.5mm or less Terminal connection screw: M5 Acceptable electric wire: 1.25mm2 Rear panel L N Terminal block GFCI Electrical entry Connect to earth cable Connector width6.5mm or less Terminal connection screwM3 Acceptable electric wire:1.25mm2 Please refer to page 6-3 or 14-3 for the electrical diagram.

GFCI 5. 6. 7. 13 1 13 R 13-2 IDFA6E-20-R 5A 30mA 13-3 1) 2) 3) 9.5mm M5 1.25mm 2 L N 6.5mm M3 1.25mm 2 6-3 14-3 13 2 14 T 14 T T 14-2, 14-3 14-1 1. 2. 3. GFCI 4. 5. GFCI 6. 7. 8. 9.

Front panel To the users machine Terminal connecting screw: M5 Connector width: 9.5mm or less Applicable electrical wire: 1.25mm2 or more L ,N: Power supply N L GFCI Ground fault display button (white) Electrical test button (gray) entry 10-4 Cautions for handling the GFCI 1) When the breaker is tripped, cut off the power supply and contact the nearest sales distributor or SMC sales.

(1 ) 2. 3. 0 IDFA Series 9-3 (ADH4000-04) 9 2 IDX-OM-W032 10 R 10 R 10-1 10-2 IDFA22E/37E/55E-23-R 10A 30mA IDFA75E-23-R 20A 30mA 10-3 (IDFA55E,75E) (IDFA55E,75E) M5 9.5mm 2 1.25mm L ,N N L () () IDFA Series 10-3 10-1 IDX-OM-W032 10 R 10-4 () () ONOFF 10-5 R 6-4 6-3 T 11-6 11-3 IDFA Series 10-4 10-2 IDX-OM-W032 11 T 11 T T 11-211-3 11-1 1. 2. 3.

-10 300mm () AMC 0 VBA-OM-O005-A 1.2 2 VBA22AVBA42A 0.5MPa 0.5MPa 0.1MPa 0.1MPa 2.7 (4 VBA1A VBA2A, 4A VBA43A 2.2 2 3.7 4 2.0MPa 1MPa 1.6MPa OUT 3 () 3 0 AF AM 3 INOUT VBA2VBA4 AF AM () INOUT ()() AR20AW20 2 0.8MPa 0.4MPa + 0 30s (MPa) P IN OUT URL http://www.smcworld.com E 0.8MPa (MPa) 2012 SMC Corporation All Rights Reserved (0L/min)

No gap Booster regulator Air tank Booster regulator A B C D E F G H I J K L M Grooves There should be no damage or dust O-rings VBAT05A1 VBA10A VBA11A 150 374 370 307 163 160 100 200 Rc 3/8 257 60 Rc 1/4 20 Air tank There is a slight play on the diagonal parts.

VBA2: Tightening torque: 24 Nm (M10) VBA1: Tightening torque: 3 Nm (M5) Air tank (3) (2) (1) (4) Grooves O-rings (4) O-ring

softness of tubing e) Loosening of the union nut (3) Do not repair the fittings or patch the tubing for reuse. (4) After operation at a high temperature, leakage may occur due to time dependent change of the tube material.

regular maintenance, check for the following and replace any components as necessary. (5) Connection thread: G Tighten fittings with sealant using the proper tightening torques in the table below. a) Scratches, gouges, abrasion, corrosion b) Leakage Connection Proper tightening torque c) Flattening or distortion of tubing thread size Nm d) Hardening, deterioration or softness of tubing e)

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, EA, IT2000 3/8 INCPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV205------------

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., REGULATOR, ELECTRO-PNEU, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, E7, IT2000 3/8 INCEUROPEAN, 1.05600 lb

A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV203------------