(Page 82) H_1 (Setting of OUT1 hysteresis) Setting of OUT1 hysteresis (Hysteresis) 2 R/W U16 200 Y Setting range Refer to "Settable range list". (Page 82) P1L (n1L) (Lower limit of window comparator) Setting of OUT1 output set value (Lower limit of window comparator) 3 R/W S16 1200 Y 1220 0x04C4 Setting range Refer to "Settable range list".
(Custom range) Relationship between analogue input and digital display Set value A B 200 0 L/min 200 L/min 500 0 L/min 500 L/min 1000 0 L/min 1000 L/min 2000 0 L/min 2000 L/min 3000(Default) 0 L/min 3000 L/min 6000 0 L/min 6000 L/min 12000 0 L/min 12000 L/min 16000 0 L/min 16000 L/min 20 0 L/min 20 L/min USEr Input value (setting) Input value (setting) -31No.PF-OMU0007-D
Max. 1 NL/min 10 NL/min PF2A710 3.5 CFM x 10-2 35.0 CFM x 10-2 5 NL/min 50 NL/min PF2A750 18 CFM x 10-2 176 CFM x 10-2 10 NL/min 100 NL/min PF2A711 3.5 CFM x 10-1 35.5 CFM x 10-1 20 NL/min 200 NL/min PF2A721 7 CFM x 10-1 71 CFM x 10-1 50 NL/min 500 NL/min PF2A751 18 CFM x 10-1 176 CFM x 10-1 : Analogue output is based on the rated flow range at normal condition.
. *1 Applicable fluidconductivity *1 5S/cm or more (micro Siemens/cm) Detecting method Electro static cupacity Ground*10 Negative ground Rated flow range 0.5 to 20 L/min 2.5 to 100 L/min 5 to 200 L/min Display range 0.424.0 L/min 2.0 to 120.0 L/min 4 to 240 L/min Set point range 0.424.0 L/min 2.0 to 120.0 L/min 4 to 240 L/min Zero-cut flow *2 0.4 L/min 2.0 L/min 4 L/min Min. setting unit
[%F.S.] 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 [s] [S] [MPa] [MPa] [MPa] [MPa] [ [ [ [ ] ] ] ] 2 69 No.LFE*-OMY0008 / / / / A B C 1 V 1.1 V 5 V 4 mA 4.4 mA 20 mA [L/min] LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 70 No.LFE*-OMY0008 2x )M12 () 1.6mm A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67
The proof pressure is double the operating pressure range. -70No.LFE*-OMZ0011 Analogue output Flow/Analogue output Output A B C Voltage output 1 V 1.1 V 5 V C Current output 4 mA 4.4 mA 20 mA Rated flow [L/min] Model B Minimum Maximum A LFE1 0.5 20 LFE2 2.5 100 Flow rate 0 Minimum Maximum rated flow LFE3 5 200 rated flow Out of range -71No.LFE*-OMZ0011 Dimensions Note) The electrical entry
. (5) Any fluid which corrodes the internal fluid contact parts cannot be used. -25No.LFE*-OMZ0012 Characteristics Chart Flow rate characteristics (pressure loss) LFE1 LFE2 0.02 0.02 Pressure loss [MPa] Pressure loss [MPa] 0.015 0.015 0.01 0.01 0.005 0.005 0 0 0 5 10 15 20 0 20 40 60 80 100 Flow rate [L/min] Flow rate [L/min] LFE3 0.02 Pressure loss [MPa] 0.015 0.01 0.005 0 0 50 100 150 200
100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line) Ball screw + Belt (parallel) Guide type Linear
Unit 3 Inrush current filter 0.1 ms Sets the time to ignore the input signal change. 20 ms 1.0 ms Selects the time for filtering. 1.0 ms Unit 4 Input filtering time 10 ms 1.0ms Sets the time to hold the input signal. 200 ms 5 Input extension time 15 ms Selects the time to hold the input signal. 15 ms Unit 100 ms Enable Generates an error.
Disable Does not ignore excess current Enable Ignores excess current. 2 Inrush current filter (Inrush) 0.1 ms 1.0 ms 10 ms 3 Input filtering time (Filter_T) Sets the time to ignore the input signal change per unit 20 ms Selects the time for filtering. 1.0 ms 1.0 ms 15 ms 100 ms 4 Input extension time (SigExt_T) Sets the time to hold the input signal per unit. 200 ms Selects the time to
> Network information including the GW unit MAC address and communication speed are displayed. 38 No.EX-OMS0014-A Specification Specifications Basic Specifications Item Specifications Power supply voltage range Power supply for input and control: 24 VDC 10% Power supply for solenoid valve: 24 VDC +10%/-5% Power supply for input and control: 6.2 A (GW unit internal current consumption: 200
Selects the time to hold the input signal. 15 ms 200 ms Memorizes the number of times the input device is ON. Generates error per channel when the operation count exceeds the set value. 3 Enable Generates an error.
Specifications Table. 9-1 EX245-EA2-1 specifications Item Description General Dimensions (W x L x H) in mm 28.6 x 120 x 61.5 Weight 200 g or less Housing material Nylon Table. 9-2 EX245-EA2-2 specifications Item Description General Dimensions (W x L x H) in mm 14 x 120 x 61.5 Weight 100 g or less Housing material Nylon NOTE EX245-EA2-2 can be used to have a special bracket which must be
LAT3LAT3MLAT3F600 350 700 Load weight1000g Load weight1000g Load weight1000g 300 600 Positioning time [ms] Positioning time [ms] Positioning time [ms] [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
type) Displacement m Displacement m 200 200 150 150 130 120 50 50 MSZA30A (High precision type) MSZA50A(High precision type) D70 60 50 40 30 20 10 0 120 100 80 60 40 20 0 Load N Load N 291 Rotary Table Air Consumption Air consumption is the volume of air which is expended by the rotary tables reciprocal operation inside the actuator and in the piping between the actuator and the switching
IC circuit 5 V A76H A96V A96 Yes A72 A73 A80 A72H A73H A80H 200 V Solid state switch Reed switch Grommet 100 V 12 V IC circuit A90V A93V A90 A93 5 V, 12 V 12 V 12 V No Relay, PLC 2-wire 24 V Yes Connector A73C A80C A79W F7NV F7PV F7BV J79C F7NWV IC circuit 5 V, 12 V No Grommet Diagnostic indication (2-color display) Yes 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F9NV F9PV F9BV M9N M9P M9B 5 V,
ASS ASR ASF Male thread Proper tightening torque Nm Width across flats mm Nominal size of adjustable angle wrench mm M5 1/6 turn after hand tightening 8 100 12 17 19 24 7 to 9 12 to 14 22 to 24 28 to 30 1/8 1/4 3/8 1/2 150 200 200 200 Lock Nut Tightening Torque Caution 1. The proper tightening torque for the hexagon lock nut is as shown in the table.
, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.