SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2WA20-5DZ-M9PVSAPC"

Function: 3 Position Exhaust Center, Piping: Base Mounted w/Metering Valve, Exhaust: Individual, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: -, Port Size: -, Option: -

Function: 3 Position Pressure Center, Piping: Base Mounted, Exhaust: Individual, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: -, Port Size: -, Option: -

Function: 3 Position Pressure Center, Piping: Base Mounted w/Metering Valve, Exhaust: Individual, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: -, Port Size: -, Option: -

Function: 2 Position Single, Piping: Base Mounted, Exhaust: Individual, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: -, Port Size: -, Option: -

Magnet: Built-in, Mounting: Through Hole [Standard; 12 through 63 Bore], Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole [Standard; 12 through 63 Bore], Bore Size: 32mm, Port Thread Type: NPT 32-63 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Through Hole [Standard], Type: Standard, Bore Size: 32mm, Port Thread Type: G 32-100 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Both Ends Tapped, Type: Standard, Bore Size: 40mm, Port Thread Type: NPT 32-100 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Type: Standard, Bore Size: 16mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole [Standard], Type: Standard, Bore Size: 40mm, Port Thread Type: NPT 32-100 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: None, Mounting: Through Hole [Standard], Type: Standard, Bore Size: 40mm, Port Thread Type: NPT 32-100 Bore, Stroke: 5mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket