SMC Corporation of America
Elite Part Number Search
Search Results "CDA2KB50TN-200"

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Series: NCDA1 (Standard w/ Magnet), Mounting: R (MS4, Side Tapped), Bore Size: 200 (2"), Stroke: 0700 (7")

Magnet: D (Built-in), Mounting: L (MS1, Foot), Bore Size: 150 (1 1/2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: None, Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 037 (3/8"), Body Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 200 (2"), Stroke: 1000 (10"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

Double acting, single rod, non-rotating, direct mount, Bore size *: 20, 25, 32, 40, 50, 63, Standard stroke *: 25, 50, 75, 100, 125, 150, 200, 250, 300, Auto switch capable, Variety of lead wires and prewired connectors CG/CG3 ROUND BODY CYLINDER. CYL NON ROT, DIR MT. ACTUATOR. 20MM CG NON-ROT AUTO-SW. 5.07063 lb. HL.

Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1 Cylinder. 1.28 lb. 335.

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Magnet: D (Built-in), Mounting: E (Double End), Bore Size: 200 (2"), Stroke: 0300 (3"), Cushion: C (Urethane), Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1, Air Cylinder. 2.71 lb. 335.

Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1, Air Cylinder. 0.38 lb. 335.

Magnet: None, Mounting: A (Both Ends Tapped), Overall Length: Standard, Bore Size: 200 (2"), Stroke: 012 (1/8")

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less