Otherwise, malfunction may result due to noise. If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected for use, switching noise will be superimposed and it will not be able to meet the product specifications.
Otherwise, malfunction may result due to noise. If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected for use, switching noise will be superimposed and it will not be able to meet the product specifications.
Otherwise, malfunction may result due to noise. Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
The output condition is also basically recovered to that before a power cut or deenergizing, but may change depending on the operating environment. Therefore, check the safety of the whole facility before operating the product. If the facility is using accurate control, wait until it has warmed up.
The output condition is also basically recovered to that before a power cut or de-energizing, but may change depending on the operating environment. Therefore, check the safety of the whole installation before operating the product. If the installation is using accurate control, wait until the product has warmed up (approximately 10 minutes).
If the screen does not need to appear the next time, tick the box for Do not show this dialog box at startup After selecting, click the [OK] button. (10) On the first boot, Windows Security Alert concerning a Firewall may be displayed.
If the SI unit is not assembled properly, inside PCBs may be damaged or liquid and/or dust may enter into the unit. Note: Each output can be set under individual conditions through the network. Accessories HW/SW mode setting (switch No.1) Set the setting method, either by local or by network, for the setting of address and speed.
When the NFC reader / writer is held over the wireless unit, an error message may appear, such as Device driver software was not successfully installed or Smart card was not identified depending on the version of Windows OS. The reader / writer can be continuously used.
This may be due to some accident such as excessive external force, contamination, or electrical malfunction. If this happens, it is possible to replace an individual supply unit for one lline without having to replace the entire manifold. The supply unit may consist of a basic block, a flow adjustment or stop valve, or a combination.
This may be due to some accident such as excessive external force, contamination, or electrical malfunction. If this happens, it is possible to replace an individual return unit for one lline without having to replace the entire manifold. The return unit may consist of a flow sensor block with or without a flow adjustment or stop valve, a temperature sensor, or a combination.
This may be due to some accident such as excessive external force, contamination, or electrical malfunction. If this happens, it is possible to replace an individual return unit for one lline without having to replace the entire manifold. The return unit may consist of a flow sensor block with or without a flow adjustment or stop valve, a temperature sensor, or a combination.
This may be due to some accident such as excessive external force, contamination, or electrical malfunction. If this happens, it is possible to replace an individual supply unit for one lline without having to replace the entire manifold. The supply unit may consist of a basic block, a flow adjustment or stop valve, or a combination.
Do not block this port as doing so may lead to a malfunction. Install a silencer if you are concerned about the noise. (There may be a PE port even when the pilot valve’s exhaust is collectively exhausted, such as with the new SY series.)
The SX3000/5000/7000 series was discontinued in May 2020.
Consider the SY3000/5000/7000 series as a substitute.
Some SX series valves may be available for maintenance purposes, so check the part number on the valve and ask your nearest SMC sales office about availability.
Note) SX series valves and SY series valves are not interchangeable mounting or connector wise.
If the bolt holder position is adjusted improperly at this time, the bolt holder will interfere with the switch groove and may interfere with switch mounting.
Note) If ø6 and ø10 CXSJ series cylinders are operated without using the bolt holder, the bolt holder may drop.
If the product is operated with the bumper bolt removed, the piston may hit the head cover and cause damage to the cylinder. In addition, if tightened without the nut, the piston seal may get caught in the leveled part of the tube, resulting in damage. The adjustable stroke range of the bumper bolt is 0 to -5 mm for the standard stroke.
2) If internal leakage of the valve or leakage of the piston seal occurs, air may collect around the lock mechanism, and the lock may be released.
For the pressure center type
1) When air is supplied to both sides at the center position, the lock is released.
Note 1) If an MY1B10-X1810 or MY1H10-X1810 is equipped with a reed auto switch, the auto switch may not respond.
Note 2) If a solid state auto switch is used with an MY1B10 or MY1H10 series cylinder without the special order part number suffix “-X1810,” the auto switch may operate at multiple points.
The sensor part in particular needs to be protected by a cover, etc., if the product may be exposed to liquids in the operating environment.
Depending on the operating conditions, the stroke length may be longer or the operation may be stiff near the stroke end. In such cases, use the stopper nut to limit the stroke amount.
Note) For RB-OEM series shock absorbers, install an external stopper.