A large differential pressure may have been generated momentarily during cylinder operation.
Factors that cause a large differential pressure include changes in speed and an increase in hydraulic oil viscosity due to changes in temperature (in winter), which may also cause aging of the pump. Check the situation and contact SMC if you require further assistance.


When temperatures are low, such as in winter, the viscosity of the hydraulic oil used may increase, and the differential pressure indication switch may mistakenly be activated.
In such cases, wait until the fluid temperature rises after it is warmed up, and reset the differential pressure indication switch before starting the main operation (20°C or higher is recommended).


When temperatures are low, such as in winter, the viscosity of the hydraulic fluid used may increase, and the differential pressure indication switch may mistakenly be activated. In such cases, wait until the fluid temperature rises after it is warmed up, and reset the differential pressure indication switch before starting the main operation (20°C or higher is recommended).

Faulty sealing of the check valves or accumulation of dust may cause operation to stop, so slurry processing is not available. Refer to page 586 for maintenance parts. Note 1) The values given for discharge and suction head are for no piping. Values will depend on piping conditions.

When used in a conveyor line, the object may be pushed back by the built-in spring force after energy is absorbed. For backlash, refer to the spring force in the specifications. (Pages 886 and 887) 5.

Scratches and gouges may damage the packing, causing air leakage or malfunction. CE1 Operation (RSA) CE2 Caution 1. Do not apply external force from the opposite direction to the end lever type locking mechanism when the lever is locked. When pallets move during conveyor adjustment, first lower the cylinder. 2. Be careful in the space between the cylinder and the lever holder.

Dimensions L, Z, and ZZ are reference dimensions for installing a double knuckle joint, which may be used as a guide. +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.058 0 +0.070 0 +0.070 0 107.5 117 127 155 159 107.5 117 127 155 159 115.5 127 137 171 175 CD-MU03 CD-MU04 CD-MU05 CD-MU05 Single Clevis (Pivot Bracket for Double Clevis

When two switches are connected in parallel, malfunction may occur because the load voltage will increase when in the OFF state.

If the valve is energized without air supply, the coil may be burned. Make sure to supply pressure to the valve when energizing. 4. Power consumption 4 W type: Available 2. Please contact SMC for the product usage with a voltage at 75 VDC or more. Standard required by CE mark is different. 3.

Abnormal temperature rise caused by adiabatic compression may result in the tube bursting. 2. The minimum bending radius indicates the value at a temperature of 20C with an outside diameter rate of change of 10% or less. 3. Please exercise caution when using this item in a clean room.

At higher temperatures, the outside diameter change rate may exceed 10% within the minimum bending radius. Caution The TPH series was specially designed for clean blowing and washing lines. Please consult with SMC for use in other applications. Materials: The durability of polyolefin resin against mineral oils is inferior.

Abnormal temperature rise caused by adiabatic compression may result in the tube bursting. 3. The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure above. T T IDK 473

Use a nylon or polyurethane tubing for general industrial water, otherwise the tube may result in being fallen out or bursted when the max. operating pressure is lower and the surge pressure is occurred. 2. Abnormal temperature rise caused by adiabatic compression may result in the tube bursting. 3.

Either may be used. 02 VVEX 2 1 6 Thread type Example for ordering a manifold base: The valve and blanking plate for manifold arrangement should be specified in order from the left side of the manifold base (with the port 2(A) on your side). (Example) VVEX2-2-3-02N * VEX3222-1LO1 2 pcs. * VEX1-17-3A1 pc.

If mounted in a wrong direction, the equipment to be connected may result in a malfunction. Refer to the dimensions for mounting.

vary depending on the application and operating conditions. 2) 6 psi (0.04 MPa) differential for CR seat. 3) Tested with inlet pressure 500 psig (3.5 MPa). 4) Weight, including individual boxed weight, may vary depending on connections or options.

Note 6) Due to the softness of polyurethane tubing, it may fold when being inserted. Hold the end of the tubing and insert it all the way in. 840

Damage to the solid state pressure sensor may occur. Switch assy O ring Gasket Base 3.8-4 ISA Dimensions/Centralized Wiring (Terminal Block Box Style) Unit Manifold With bracket Deflection level indicator Terminal block box 34 L2 40 34 L1 Deflection level indicator Terminal block box 75 40 90 10 10 10 Rc1/8 SUP.

Otherwise, it may result in a malfunction. 1. Float type auto-drain (N.O.) 1) Use compressor with capacity more than 3.7 kw {400 l/min Be sure to pipe auto-drain under the following conditions. Otherwise, it may result in a malfunction. 1. Float type auto-drain (N.O.) When making drain exhaust piping, use piping with bore size 10 or larger than 10. Length should be shorter than 5 m.

Note 2) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it will may result in a breakdown. (Fastening torque recommended: 7 to 9 Nm.) For sealing, use a pipe tape.