Switch 5 to 24VDC Load current (1C): 100mA, Internal voltage drop: 0.8V or less Load current (1C): 40mA, Internal voltage drop: 0.4V or less Specifications Note) When the work load exceeds 15kg, the speed may be limited. Contact SMC in this case.
At higher temperatures, the tubing may fold at more than the minimum bending radius. 4. Store away from direct sunlight in a location at no more than 40C. 1981-2000 Reprint May 2000 6
(Excessive force in the direction of rotation applied to the piston rod may damage the internal mechanism.)
However, depending on the number of auto switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the auto switches.
There may be the case it will vary substantially depending on an ambient environment.
When an impact, such as water hammer, etc., caused by the rapid pressure fluctuation is applied, the solenoid valve may be damaged.
{Tightening torque: 0.8 to 1.2Nm} If the exhaust of the double check block is throttled too much, the cylinder may not operate properly and may notstop intermediately. Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
Additionally, be aware that the transferred object may be pushed back due to the return force of the shock absorber. MIW MIS 40 30 20 3.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 1.
Oscillation (beat) may occur with some operating conditions even if the operation is within specification. Contact SMC for that case. VEX SRH SRH SRP Mounting Caution SRF 1. Open the sealed package inside a clean room. These products are packaged in sealed double packaging in a clean room.
If they receive 10 N or more of force, a malfunction may occur. 3. Do not pull the lead wire with excessive force. Applying 10 N or more of load may result in broken wire or contact failure. Manual Override Caution 1. To operate the manual override to the ON position, press the button fully in the direction of the arrow (approximately 0.5 mm).
Units may be base mounted or panel mounted.
Supply source If the primary side air is throttled, flow may be reduced resulting in the malfunction of the switch or instability in the response time because of the pilot operated solenoid valve. Conduct piping work suited for the secondary side piping (air consumption).
Possible physical effects may occur such as penetration and swelling due to temperature, pressure and chemical density. To use tubing in a solvent environment, tests should be performed with the same environment to ensure no problem occurs with operating environment.
If the bolts are too long, they hit the end plate and may cause malfunctions. 146
The product may be damaged if used in the line with continuous pressurisation. 3. Modification prohibited Do not make any modifications, including additional machining. It may cause human injury and/or an accident and will void the warranty. Mounting Warning 1. Maintenance space Allow sufficient space for maintenance and inspection. 2.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
Otherwise, the product may be damaged. (2) Do not install in areas of high humidity or high temperature.
This will cause the temperature to decrease due to air expansion, and the temperature may exceed the operating temperature limit of the air tank. If flow speed becomes faster, a loud noise may be generated by the friction inside the tube.