SMC Corporation of America
Elite Part Number Search
Search Results "PFM525-01-2-R"

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Body Size: 20, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 1/8, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Right to Left, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Type: Pressure Switch, Fluid Type: Air / Nitrogen Gas / Argon, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Output Method: NPN Open Collector / Analog, Analog Output Specification: Voltage, Pipe Port Type: [Threads] Male thread (with female thread), Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible,

Body Size: Applicable AC Size: AC20, Handle Operation: Single Action, Thread Type: Rc, Port Size: 1/8, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Right to Left, Unit: Unit of Product Label: MPa

Type: -, Connection Method: -, Compressed Air Quality: General Dry Air, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/8, Filtration Level: 5μm, Operating Environment: Standard, Operating Pressure Range(MPa): -, Flow Direction: [Left] Right→Left, Drain Cock: [Manual] Manual, Bowl Material: [Resin] Polycarbonate Case, Bowl Guard: No, Size of Body: 20, Accessory: None, O-Ring, Gasket

Body Size: 20, Thread: Rc, Port Size: 1/8, Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: Flow Direction Right to Left, Semi-Standard 2: Standard, Made to Order: -

Body Size: 20, Thread: Rc, Port Size: 1/8, Option: Standard, Semi-Standard 1: Flow Direction Right to Left, Semi-Standard 2: Standard, Made to Order: -

Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 1/8, Option: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Flow Direction: Right to Left, Made to Order: -

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.02 to 2 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: Rc1/8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -

Size: 20, Thread Type: Rc, Port Size: 1/8, Mounting: w/o Mounting Option, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Flow Direction: Right to Left, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa/°C