to 24 VDC ZNR ZNR 12 to 24 VDC SOL DC () 100 to 200 VAC SOL 2 DC () ZSE ISE 2 ( ) PNP open collector output Conduit terminal DIN type connector With indicator light AC Circuit Conduit terminal With indicator light DC circuit PSE DC (+) 1 ( ) 1 DC (+) MAX 80 mA Rectifying device Z I SE3 OUT Load 12 to 24 VDC ZNR ZNR 100 to 200 VAC 12 to 24 VDC SOL SOL DC () PS 2 ( ) LED 2 DC () indicator
Refer to p.4.1-12, 4.1-13 for specifications and model.
to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% Temperature characteristics 2% F.S. 2% F.S. (15 to 35C) 2% F.S. (15 to 35C) (25C standard) Monitor unit Monitor unit Monitor unit Monitor unit 3% F.S. (15 to 35C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) (15 to 35C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C)
Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR SIGNAL OUTPUT . 12-1 12.3 REMOTE OPERATION . 12-2 12.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 12-3 12.5 ELECTRIC CIRCUIT . 12-4 Chapter 13 Option V . 13-1 13.1 SAFETY INSTRUCTIONS FOR USE . 13-1 13.2 SPECIFICATIONS . 13-1 13.3 MAINTENANCE . 13-2 Chapter 14 Inspection record . 14-1 14.1 INSPECTION RECORD .
Specification for Option_L 12 1 Safety instructions . 12 1 12 2 Specification . 12 1 12 3 Installation . 12 2 12 4 Maintenance . 12 2 Chapter 13 Specification for Option_R 13 1 Safety instructions . 13 1 13 2 Specifications of the GFCI . 13 2 13 3 How to connect the power supply . 13 2 Chapter 14 Specification for Option_T 14 1 Safety instructions . 14 1 14 2 Specifications . 14
V 12 V V 12-2 12-1 1. 1 2 2. 3.
Specification for Option V 12 1 Safety instructions . 12 -1 12 2 Specifications . 12 -1 12 3 How to perform maintenance. 12 -2 12 4 Electric circuit . 12 -2 Chapter 13 Service Record 13 1 Service Record . 13 -1 Table of Contents 2 IDX-OM-W034 Air Dryer i Safety Instructions i Safety Instructions Before use,read and comprehend important cautionary notification well on this operattion manual
Analog output Current output 4 to 20 mA Linearity: 5% F.S. or less; allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC 12 to 24 VDC (ripple 10% or less) Power supply voltage 20 mA or less Current consumption (No load) Enclosure IP65 Operating temperature range Operating: 0 to 50C, Stored: 25 to 85C (with no freezing and condensation) Withstand voltage 1000 VAC for
For sub-plate style, manifold type 41, S41, 42, S42, 42R, S42R (With gasket and screws) Body option Nil: Individual pilot exhaust style Electrical entry Manual override 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC Nil: Non-locking push type Grommet L plug connector M plug connector M8 connector R port P, E port G: Lead wire length 300 mm MN: Without lead wire WO: Without
(Refer to page 12.) 11 Multi-Axis Step Motor Controller JXC73/83/92/93 Series Wiring Example 1 For 4 Axes 1 pc.
(For communication cable) Weight*9,*12 kg 134 *1 Use fluid that fulfills the conditions below as the circulating fluid.
Zener barrier) for apparatus group IIC with the following maximum values: Ui = 28 V Ii = 225 mA (resistively limited) Pi = 1 W Ci = 0 nF Li = 0 mH Confirm the solenoid input voltage at the lead wires is 12 VDC 10%. The resistance of the solenoid valve is R 20 + 278 3% Ohm at 68F (20C). Do not bend or pull cables repeatedly.
Weight (g) d T H D1 D2 D3 L1 L2 L3 Model 4 ASD230FM-M5-04 9.3 12.9 17.5 29.4 12 29.6 33.8 28.8 34.6 9.6 10 7.8 11.7 M5 x 0.8 8 30.1 25.1 6 ASD230FM-M5-06 11.6 13.7 20.6 32.5 13 34.6 6 ASD330FM-01-06S 39.6 14 11.6 13.7 29 22.9 38.5 35.2 30.2 14.2 11.8 10.6 R 1/8 12 32.1 27.1 15.8 33.9 8 ASD330FM-01-08S 38.9 15.2 18.5 31 28.2 44.8 6 ASD430FM-02-06S 12.8 17 53 25.2 43.5 18 8 ASD430FM-02-08S
150 135 13 4 185.5 175 154 16 5 198 187.5 173 12.5 6 223 212.5 192 15.5 7 235.5 225 211 12.5 8 260.5 250 230 15.5 9 273 262.5 249 12 10 298 287.5 268 15 (mm) Stations L1 L2 L3 L4 11 310.5 300 287 12 12 335.5 325 306 15 13 348 337.5 325 11.5 14 373 362.5 344 14.5 15 385.5 375 363 11.5 16 410.5 400 382 14.5 17 423 412.5 401 11 18 448 437.5 420 14 19 473 462.5 439 17 20 485.5 475 458 14 3-3
XLA XLFV/With solenoid valve J XL XL XLQ XM XY M N Port P D(Pressure port) XSA K L P R XVD XGT Port R (Exhaust port) CYV (mm) (mm) J J K L M N K L M N Model XLFV-16 XLFV-25 XLFV-40 XLFV-50 Model XLFV-63 XLFV-80 XLFV-100 XLFV-160 35.5 12.3 10.2 3.6 3.6 78.5 28.7 12 4 2 40.5 13.8 10.2 3.6 3.6 87 38.7 12 4 2 50.5 21.6 10.2 3.6 3.6 105.5 49.7 12 4 2 67 21.7 12 4 2 128.5 58 12 4 2 Other dimensions
16 20 24 1500 2000 2500 3000 1,000 2,000 3,000 Max. speed Vmax (mm/s) Graph 3:40 40 8 10 1/4, 3/8 h=0.7 6 500 30 0.5 40 (3/8) 12 18 24 30 36 1000 1500 2000 2500 3000 3/8 12 3/8 12 3/8 12 3/8 12 3/8 12 0.1 0.3 20 10 Note) Refer to p.4.10-5 for max. absorbed energy since cushioning ability may in some cases exceed the allowable cushioning ability if the cylinder is used under high speeds and
System error (Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 24 VDC 10%. (2) Supply power in the range 12 to 24 VDC 10%. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range.
12 18 2 A 16 U 17 21 23 2B 9 10B 11 9 27 15 12 14 B 11 27 13 12 9 2A 2 2B 2 12 18 2 7 - 3-4 2B2C A 16 17 12 18 2 8 9 13 B 11 9 10 17 A 16 12 18 2 2 O 3 19 12 27 12 14 27 15 12 12 3-5 2C2B OPENCLOSE 9 B 11 10 A 16 18 2 2 12B 11 9 27 13 12 14 27 15 9 B 11 12 13 2 19 3-6 2B 2A 2 18 12 9 2 21 23 3-7 20 22 24 8 8 - 4.
-Positioner mounting threads have -Ensure that the positioner mounting threads have not loosened. 10 to 12 loosened. -Positioner and actuator are -Check the connection between the positioner and actuator. 10 to 12 improperly connected. -Input current system is unstable. -Adjust the input current system. -Calibrate the input current with the parameter mode. 26 -Others.
. 12-1. 2 12-2. 1) 1) 2 3) 1ISOVG32 8 4 0.7 12-3. 1 12-4. 1) 1.52 13. 1 2 1 1060 14. 12 9 15.