SMC Corporation of America
Elite Part Number Search
Search Results "PF3W740-04-AT-G-X109"

Body Size: 40, Back Flow: K (w/Backflow), Thread: N (NPT), Port Size: 04 (1/2), Mounting Option: B (With Bracket), Float Type Auto Drain Option: Without Auto Drain, Pressure Gauge/Switch Option: G (Round type pressure gauge with limit indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 2 (Metal Bowl), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow

Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: BG (B + G), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard

Special Applications: 10- (Clean Room Compliant), Size: 40, Backflow Function: None, Thread: F (G), Port Size: 04 (1/2), Accessory: E3 (PNP Output, Electrical Entry: Wiring Bottom Entry), Specifications: 0.005 to 0.4MPa Setting, Pressure Unit: ZA (Digital Pressure Switch: w/Unit Coversion Function)

Body Size: 40, Model Type: C (Air Filter + Mist Separator + Regulator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.

10 mA (2 V or less at 40 mA) Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Operating range .

FGG P.C.D B E F FGA C A (mm) Applicable model G H I Part No.

Action in the case of error If any error such as an abnormal sound, smoke, or bad odor occurs, cut off the power at once, and stop supplying and conveying fluid. Please contact SMC or a sales distributor to repair the thermo-con. 3. Regular inspection Check the following items at least once a month.

)mm 28.616061.5 150 g . 10-5 EX245-EA2-5 Item (WLH)mm 27.612061.5 120 g 73 No.EX-OMW0014CN-A 11. 11.1.

Insulation resistance Between external terminal batch and case: 2 M (at 500 VDC) 2 hrs. each in X, Y, Z directions at smaller of 10 to 500 Hz with amplitude 1.5 mm, or acceleration 10 G Vibration resistance Impact resistance 100 G in X, Y, Z directions, 3 times each Note) Not available on analog output type.

Indicator light 3.5 to 7 82.5 75 01T 02T M type plug connector (M): VQZ2 5(R)M 56.5 (Lead wire lnegth) Cover diameter 1.5 Cross sectional area 0.23mm2 58 300 77 89 Indicator light 28 Base Mounted Type Series VQZ Dimensions: VQZ300 VQZ300 (mm) Valve Scale: 45% Grommet (G): VQZ3 5(R)G 02T 03T 37 5 2 4.5 Mounting holes 23.5 R5 Cover diameter 1.4 Cross sectional area 0.2mm2 Manual override 2

Confirm that the green LED is on when stopped at the established position.

Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature. (Default settings) Impact resistance: No malfunction occurred when it was tested with a drop tester in the axial direction and at right angles to the main valve and armature in both energized and deenergized states once for each condition.

When the magnet for auto switch is necessary, add -M9// at the suffix of the part number. (There is no magnet for auto switch for high temperature.) e.g.) XLA16-30-1-2M9// Note 3) Auto switch is not attached. When the auto switch is necessary as a set, add the symbols of the auto switch at the suffix of the part number. e.g.)

g',,'-___ : ','(); Pin:t12"",: g= WL idth across fl~tsl 4.7 ./ ClevIS wld!h CK 1A :1 6.s=+P 40 80+ Stroke ZZ+ StJoke 2 CK1B : 195!

Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.

Press the SET button at least 2 seconds.