11 12 VXD23 to 29 136 Construction VXD Series Normally Open (N.O.) !
Limited at the stroke end Limited at the stroke end +3 +3 +3 +3 direction + direction direction + direction 8 11 8 11 0 5 10 stroke end 0 5 10 stroke end [mm] [mm] The Card Motor performs relative positioning operations as shown below if the table starts from a position outside of the software stroke range, for example when the table has reached the mechanical end stop in pushing operation
Max 1.25 9 80 92 108 8 M1 OX 1.S 15 18 M1 Oxl .5 9 63 103.5 MIOx l .S 11 99 116 13' 10 M1 6X2.0 21 22 M12xl .7S 11 123 Ml 2x 1.75 80 Clevis Mount: C0020P 0 -0 OM-DO Special cap bolt (mm) eo.. _ N CD CL ew ev A 0 R CU ex cz RR Ll H H Thread e I (mm) C Depth M8xl .2S M8x l .25 14 117 I .
Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 (EX600-DXE) 1 2 3 4 5 6 7 8 0 2 4 6 8 10 12 14 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 14 15 16 17 18 19 20 21 1 3 5 7 9 11 13 15 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 -30No.EX-OMN0035CN-A (EX600-DXF) 0 1 2 3 4 5 6 7 2 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 3 Bit 1 Bit 3 Bit
N.O. 125 VAC 15 15 4 2 10 10 4 2 250 VAC 15 15 3 1.5 10 10 3 1.5 8 VDC 15 15 3 1.5 15 15 5 2.5 15 15 3 1.5 10 10 5 2.5 14 VDC 30 VDC 3 6 6 1.5 5 5 5 2.5 125 VDC 0.5 0.5 0.3 0.3 0.05 0.05 0.05 0.05 250 VDC 0.25 0.25 0.2 0.2 0.03 0.03 0.03 0.03 16-12-6 2 Paddle Style Flow Switch Series IF3 Fluid and Ambient Temperature Range Enclosure Open type Using indoors away from water drop.
L/min 10 L ON OFF ON OFF , , 2 5 10 L/min 5 ,10550 L -14No.PF-OMM0004-D ON-OFF 1 L/min ,10 11 12 1 L/min () SI SI PF3W ON-OFF () ON 0 PVC -15No.PF-OMM0004-D IN IN (75 ) 9022545 -16No.PF-OMM0004-D (PF3W704/720/740 ) (M44 ) 8 1.5 mm (81 ) (PF3W711 ) (M54 ) 2 mm (81 ) -17No.PF-OMM0004-D (PF3W704/720/740 ) 3.04 8 0.50.7 Nm (81 ) ,, (4 ) (PF3W711/721 ) ,(4.0,4 ) 1.01.2
Form w 1 Material 12 N S U F GN GS 10 10 11 1 ZP UT 13 13 14 1.5 16 16 17 Y 2.5 1 N: NBR, S: Silicone rubber, U: Urethane rubber, F: FKM, GN: Conductive NBR, GS: Conductive silicone rubber A B Construction p. 115 Mounting Bracket Assembly From p. 121 With adapter 10 to 16 w q ZPT UT N A5 10 e Vacuum inlet (Male thread) B Width across flats D 15.5 C A5 M5 x 0.8 A6 M6 x 1 A Model A B C D
B B For D-F8 Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch (Lm) 11-6-10
35) 10 (10) 16.5 19.2 18.4 21.6 20.5 23.2 22.4 25.6 05 20 10 A A 30 (25) 10 (10) 1 15 10 For D-F9, D-M9 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotating angle.
Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type Nil S n 2 pcs. 1 pc. n pcs.
-1/8 (OUT port) 11 P = 22 11 1.5 4.5 6 32 6 54 ( 19.5) 11 9.5 11 9.5 4-M4 x 0.7 10 24 10 46 When not equipped with bracket, the M3 threads at both ends (4 positions) can be used for other purposes.
with secondary batteries ZS-33-M-X221 90 Material restriction Mounting screw (accessory) Type Integrated display 7 R Rated flow range (Flow rate range) 10 50 11 * ( ): Fluid: CO2 0.2 to 10 (5) l/min 1 to 50 (25) l/min 2 to 100 (50) l/min Panel mount adapter (For without flow adjustment valve) Port size ZS-33-J Symbol Description Flow rate range 10 Panel mount adapter A 50 11 C6 C8 6 One-touch
81 11 M6 x 0.75 10 5 1 6.5 15 123 +0.08 0 32 5.5 10 M10 x 1.25 15 35.5 1/8 11 81 11 M8 x 1.0 12 5.5 1 7.5 24 123 +0.08 0 40 6 14 M14 x 1.5 19 44 1/8 11 92 12 M10 x 1.25 14 6 1.25 8.5 24 144 +0.08 0 50 +0.08 0 7 18 M18 x 1.5 19 55 1/4 11 107 13 M12 x 1.25 16 7.5 2 10 24 167 63 7 18 M18 x 1.5 19 69 1/4 11 107 13 M14 x 1.5 18 11.5 3 14.5 24 167 +0.08 0 80 10 22 M22 x 1.5 23 80 3/8 21 130 40
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).
57.2 59 65 70.8 76 76.9 81.3 3.4 4.4 5.1 6.1 5.2 6.3 6.7 8 7.4 8.2 9.8 10.9 10.3 11.3 7.9 11.1 11.8 12.8 12.3 13.4 16.3 17.6 19.3 20.1 21.7 22.8 22.7 23.7 20.9 23.8 24.5 25.5 28.9 30 33.2 34.5 38.6 39.4 41 42.1 51.6 52.6 11 9.8 5 6.7 9.8 10.1 12.3 11.5 12.3 15.7 16.1 8.8 2 3.2 4 6 4 6 6 8 6 8 10 12 10 12 6 8.4 9.3 11.6 9.3 11.6 12.8 15.2 13.2 15.2 18.5 20.9 18.5 21.7 12.7 3.3 5.5 9.1 11
(M12 ) (EX245-DX1EX245-DY1) IP65 0.2Nm EX9-AWTS M12 10 . 10-4 (EX9-AWTS) 66 No.EX-OMU0020CN 11. 11.1. . 11-1 . 11-1 Length the EX245 series module n 0 1 2 3 4 5 6 7 8 L 113.6 167.6 221.6 275.6 329.6 383.6 437.6 491.6 545.6 L = 54n + 113.6 (8 ) mm 67 No.EX-OMU0020CN 12. 12.1.
0.5 (Pilot port) A B 11 1.5 17.5 (For mounting) 2 x 3.2 equivalent (18.5) A B Manual override 14 36 (18.5) (21) Manual override 41.6 13.5 15 41.6 28.5 21 R2 P R1 13 R P R (11) (0.5) 10 5 5 2 x 1 (Bleed port) 10 10 7 7 2 x 1 (Bleed port) M3 x 0.5 (Piping port) 28 M5 x 0.8 (Piping port) 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust
40 200 Overhang L (mm) Overhang L (mm) Graph (7) Maximum Speed: Up to 800 (mm/s) 20 30 40 50 10 2 3 4 5 Weight W (kg) 40 32 1 0.5 0.4 0.3 0.2 16 25 20 12 0.1 50 100 200 5 20 30 40 10 Overhang L (mm) 8-10-6 6 Model Selection Series MTS Horizontal Mounting 8 Maximum speed: Up to 500 mm/s Maximum speed: Up to 300 mm/s Graph (8) Stroke: Up to 10 stroke Graph (11) Stroke: Up to 10 stroke 0.1
03, 04 100 200 01, 23 100 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations AS4201F, AS4211F AS4301F, AS4311F AS3201F, AS3211F AS3301F, AS3311F 10, 11, 12 12, 13, 16 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 1500 1000 08, 09 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 06, 07 1000 500 500 0 0 5 10 0 0 5 10 Number of needle rotations Number of needle rotations