10 10 12 12 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" -X214 Restrictor (Without check valve) With One-touch ttings Example) AS2002FS-04-X214 With indicator 10Clean Series 1 For selecting applicable tubing O.D., refer to the Model shown above. 2 Use 1/8" tubing.
No gauge port Ports No code No code M V X No pressure gauge (Connections: 1/4 inch face seal male) Code Ports 2 ports 3 ports 4 ports 0 2PW 3PW 4PW V3 L 1 2 4 10 40 -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7 MPa 0 to 28 MPa -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig Porting Configuration
Fluid:air; CO 2 ; nitrogen gas; freon 11, 113, 114; turbine oil, hydraulic fluid, argon, helium, Proof pressure: 1.5MPa, Operating pressure range: 0 to 1MPa, Effective area: 13 to 770mm 2, Coil rated voltage: AC(50/60Hz) 100V, 200V, others (option); DC 24V, others (option), Ambient temperature: -5 to 60°C (no freezing), Process valve, 2 PORT PROCESS VALVE, J07, 400 lb
rail type, Ball Screw Drive Actuator, ELECTRIC ACTUATOR, A06, 11 lb
Double acting, single rod; Bore size (mm): 40, 50, 63; Standard stroke (mm): 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500; Rc, NPT or G port threads; Clean series
06 08 10 12 4 6 8 10 12 Body size 2 Elbow Type 2 3 4 5 6 M5 1/8 1/4 3/8 1/2 Control type Port size 0 1 Meter-out Meter-in M5 01 02 03 04 M5 x 0.8 R1/8 R1/4 R3/8 R1/2 With one-touch fitting 1 Series ASG Needle Valve: Flow Characteristics ASG220F-M5 ASG221F-M5 ASG320F-01 ASG321F-01 ASG420F-02 ASG421F-02 1.5 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 200 3 400
Nominal Size: 25, Speed Specifications: Low 10 to 1000, Load Specifications: Q [Heavy Load, Nominal Size: 16 6 (10), 25 11 (20)], Stroke: 400 mm, Stroke Adjusting: Both Sides, Motor Placement: On the Bottom, Output Type: PNP, Stoppable Positioning Points: 5-point Stoppable Type, Cable Length: 5m, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, CE Compliant: -
Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Q [Heavy Load, Nominal Size: 16 6 (10), 25 11 (20)], Stroke: 400 mm, Stroke Adjusting: Both Sides, Motor Placement: On the Bottom, Output Type: PNP, Stoppable Positioning Points: 5-point Stoppable Type, Cable Length: 5m, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, CE Compliant: -
Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Q [Heavy Load, Nominal Size: 16 6 (10), 25 11 (20)], Stroke: 400 mm, Stroke Adjusting: Both Sides, Motor Placement: On the Bottom, Output Type: PNP, Stoppable Positioning Points: -, Cable Length: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, CE Compliant: -
Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Q [Heavy Load, Nominal Size: 16 6 (10), 25 11 (20)], Stroke: 400 mm, Stroke Adjusting: Both Sides, Motor Placement: On the Top, Output Type: NPN, Stoppable Positioning Points: 3-point Stoppable Type, Cable Length: 1m, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, CE Compliant: -
Incremental A/B phase (800 pulse/rotation) Serial communication RS485 (Modbus protocol compliant) Memory EEPROM Lock control Forced-lock release terminal Cable length [m] I/O cable: 5 or less, Actuator cable: 20 or less Battery Nickel hydride secondary battery 3.6V Charging time: 72 hours Battery replacement guide (Note 3) 2 years Motor allowable RPM when power supply is shutoff [rpm] 800 400
Specifications Flow-rate Characteristics Supply pressure Max. 1.0 MPa Input pressure Max. 0.7 MPa 0.7 Supply pressure: 0.7 MPa Output pressure Max. 0.7 MPa 0.6 Pressure ratio 1 : 1 Air consumption 3 L/min (ANR) or less (OUT = 0.5 MPa) 0.5 Output pressure MPa Linearity Within 1% Hysteresis Within 1% 0.4 Ambient and fluid temperature 5 to 60C Port size 1/4, 3/8 0.3 Weight 0.56 kg 0.2 0.1 0 0 200 400
Current model 1 L Released into atmosphere No fixed throttle 4 to 11 L Fixed throttle * Poor quality of air may cause operation failure. Select a model that is suitable for the desired air cleanliness by referring to Air Preparation Equipment Model Selection Guide (pages 2 and 3) for air quality. OUT IN (SUP.) OUT IN (SUP.)
Static Neutralization Characteristics e Pressure Flow Rate Characteristics IZS40/41/42 IZT40/41(-L)/ 42(-L)/43(-L) IZN10E IZF IZG10 ZVB IZD10/IZE11 IZH10 Antistatic Equipment IZG10-mm-01/IZG10-mm-02 Mode setting switch: Continuous blow 500 450 400 Flow rate [L/min (ANR)] 350 Flow setting: Max.
A digital pressure gauge is recommended for such situation or as deemed necessary. 451 AR10-A to AR40-A Series Flow Rate Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AR10-A M5 AR20-A Rc1/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 25 50 75 100 125 150 0 200 400 600 800 Flow rate L/min (ANR) Flow rate L/min
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.2~1.0, Port thread type: Rc, Auto Switches: Without auto switch (built-in magnet), Lead Wire
Mounting: L (Axial Foot), Bore Size: 20mm, Port Type: Rc, Stroke: 200mm
Mounting: L (Axial Foot), Bore Size: 20mm, Port Type: Rc, Stroke: 700mm
Mounting: L (Axial Foot), Bore Size: 20mm, Port Type: Rc, Stroke: 150mm