Grommet, Grommet terminal, Conduit terminal DIN terminal, L plug connector, M plug connector Electrical entry VT 100, 200, 12, 24, 48, 110, 220, 240 AC (50/60 Hz) DC Coil rated voltage (V) VP 24, 6, 12, 48, 100, 110 Allowable voltage fluctuation 15 to 10% Inrush VG 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA/50 Hz, 2.3 VA/60 Hz 1.8 W 2 W Note) Apparent power (AC) Holding W/o indicator light W/ indicator
(mm) Port size R 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols
2101-80 Changed part Note 2) Symbol Internal 1.3 x 10-10 (FKM) 1.3 x 10-8 External 1.3 x 10-11 (FKM) 1.3 x 10-9 w, e w e Nil A B C P1 70W 1.3 x 10-8 1.3 x 10-11 (FKM) 1.3 x 10-9 Kalrez 1.3 x 10-10 (FKM) Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 3310-75 Note 1) Values at ambient temperatures, excluding gas permeation.
V114-5LU Electrical entry L shaped plug connector (L) Coil rated voltage [V] 24 Allowable voltage fluctuation -10 to 10% Power consumption [W] 0.4 [Starting 0.4,Holding 0.1] Surge voltage suppressor Please refer to page 1367 of the Best Pneumatics catalogue. Indicator LED LED 14 - 4-3.
V114-5LU Electrical entry L shaped plug connector (L) Coil rated voltage [V] 24 Allowable voltage fluctuation -10 to 10% Power consumption [W] 0.4 [Starting 0.4,Holding 0.1] Surge voltage suppressor Please refer to page 1367 of the Best Pneumatics catalogue. Indicator LED LED 14 - 4-3.
lead wire LO L type connector w/o plug and lead wire LN L type connector with plug and pins M M type connector w/ plug and 300 mm lead wire MO M type connector w/o plug and lead wire MN M type connector w/ plug and pins Air Operated Valve DXT474-A Valve Manifold Assembly DXT475 A * * * * * * 02 * Valve Actuation Type Sup.
External pilot type is not available. 1 SYJ3 2 5 M M3 Body ported SYJ3 4 5 M 1 Base mounted Port size 3 port Nil: Without sub-plate M5: M5 port With sub-plate Coil specifications Nil Standard With power saving circuit (24, 12 VDC only) T Power saving circuit is not available in the case of W type.
4 P 5 X4 PRR COM1 () X0 6 THR X1 THS2 THS1 CM L X2 OLR N PRS2 PRS3 MC1,2 X3 EDV PE P P THR THS1,2 24V TB1,2 T V V FM1,2 SWL PRR PRS1 PRS2 PRS3 PLC GFCI EDV IDFA100F150F 6 6 6.4 IDX-OM-U022 6.
HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | Solen
P P P R R R R DIN DIN DIN DIN ISO#:EN ISO#:EN ISO#:EN ISO#:EN-175301 175301 175301 175301-803 803 803 803C C C C( ( ( ( DIN DIN DIN DIN 43650C)( 43650C)( 43650C)( 43650C)( 8mm) 8mm) 8mm) 8mm) DIN IP65() () 90 :3.57 ()JIS.C3306 0.5mm 2 3 1(p)3R2R5R1 3(R2 3(R2 3(R2 3(R2 R) R) R) R) 5(R1) 5(R1) 5(R1) 5(R1) 1 1 1 1 P P P P) ) ) ) VQZ100/1000 KQ2H06-M5 AN120-M5 KJS04-M5 VQZ200/2000 KQ2S06
kPa -0.1001.000 MPa / 10.0-105.0 kPa -105.0105.0 kPa -0.1051.050 MPa / 0.1 kPa 0.001 MPa 500 kPa 1.5 MPa DC1224 V10 (p-p)10 35 mA 2F.S. 1digit(253 ) 0.2F.S.1 digit 2.5F.S.(253 ) 1F.S. 2%F.S.(25) NPN PNP 2 80 mA (NPN) 28 V () 1 V (80 mA ) 1 1.5 ms (20,100,500,1000,2000,5000 ms ) 0 2 15 V 0.65 V 1 k 420 mA 2.420 mA 12 V 300 24 V 600 50 0.4 V 5 ms -75No.PS-OMU0002CN-D
F 22 L For compound pressure Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piping specifications Option 02 T2 G2 R 1/4 (M5 with female screw), Piping in backward direction Nil None NPT 1/4 (M5 with female screw), Piping in backward direction Bracket A G 1/4 (M5
Current output Load impedance Maximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green) 2% F.S. 1 digit (Ambient temperature of 25 3C) Lights up when switch output is turned ON.
-100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD
Refer to p.0-26 and 0-27 for Safety Instruction and common precaution of the products mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for precautions on every series.
Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.
Dedicated Controller/LC1 P.73 Controller setup software P.80 Dedicated teaching box P.82 Options P.85 Dedicated Regenerative Absorption Unit/LC7R P.86 Non-standard Motor Compatible Drivers P.89 73 2 Series LC1 Controller Single Axis Type Built-in AC Servo Driver Series LTF: Standard Motor Compatible How to Order 2V LC1 F 1 H 1 L 3 Number of axes Mounting bracket 1 3 5 1 axis M3
Electrical entry AC (50/60 Hz) DC 100, 200, 110, 220, 240 24, 12 10% of rated voltage Coil rated voltage (V) Allowable voltage fluctuation 1.55 (With indicator light: 1.65) DIN/Conduit terminal with indicator light: 1.7 1.5 Note) AC Apparent power (VA) Without indicator light Note) Power consumption (W) DC With indicator light 1.55, DIN/Conduit terminal with indicator light: 1.75 A rectifying
Z direcMn (3 1imes for each direc1lon) a o Weight 45g Oncl.O.6mlong lead wire) Note I , , c l V Port size OLR (PTI 1I8.M5XO.8 T' :NPTFl I8.M5 X O .8 Alrnosphenc pressure Rated pressure Pressure The hystelesls is 3 digits.so separate PI from P2 by 7 digits or more and set them. *1 digit IS the mmimum pressure display unit. (See the table above.)