SMC Corporation of America
Elite Part Number Search
Search Results "ARBQ5000-00-B-1"

(2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 X 30 X 39) and a 3 port, high-capacity exhaust main regulator (VEX1*00 series). Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple.

Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple.

Having the amplifier built into the electro-pneumatic pilot valve, only an external (24V DC) power supply and (1 to 5V DC) signal voltage need to be connected making handling simple.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, INTERFACE REGULATOR, VALVE, VV5Q51/55 MANIFOLD, 22, VV5Q51/55 NO SIZE RATING, 2.26259 lb


The part numbers when replacing only the upper valves for use with the existing sub-plates (pipe section) are “VS4124-00□” and “VS4134-00□.”
A gasket and bolt are included.
Ex.) VS4120-021 (port size 1/4, 100 VAC, grommet type), VS4134-002 (no sub-plate, 200 VAC, grommet type)
*The grommet lead wire color is blue for the 100 VAC type and red for the 200 VAC type.

Model: 00 (Normally Closed, N.C.), Surface Finish: 15 μin. (0.4 μm) Standard, Connections 1: MV12 (3/4 Inch Face Seal, Male), Connections 2: MV12 (3/4 Inch Face Seal, Male), Purge Port: 00 (Inlet, None; Outlet, None), Seat Material: PCTFE, Standard, Purge Port Options: None

Model: 00 (Normally Closed, N.C.), Surface Finish: 15 μin. (0.4 μm) Standard, Connections 1: TW6 (3/8 Inch Tube Weld), Connections 2: TW6 (3/8 Inch Tube Weld), Purge Port: 00 (Inlet, None; Outlet, None), Seat Material: PCTFE, Standard, Purge Port Options: None

Model: 00 (Normally Closed, N.C.), Surface Finish: 15 μin. (0.4 μm) Standard, Connections 1: FV12 (3/4 Inch Face Seal, Female0, Connections 2: MV12 (3/4 Inch Face Seal, Male), Purge Port: 00 (Inlet, None; Outlet, None), Seat Material: PCTFE, Standard, Purge Port Options: None

SMC SV1000-50-4A-C6 mfld, block cassette, SS5V1 MANIFOLD SV1000*** $18.88 Add to Quote Add To Cart Add to Cart SMC SV1000-51D-32A-00

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only)

Function: 4 (3 Position Exhaust Center), Body Option: 00 (Base Mounted Plug-in), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style)

Piping adapter assembly - old style see E*00 - New Style , Easy maintenance , Detach equipment without removing piping , Assembles to FRLs by simply tightening screws , Available with a L and T type bracket, BRACKET-AMC510 ( B ), AIRLINE EQUIPMENT, AM NO SIZE RATPART, .32340 lb

.: 07 (ø1/4"), Actuator Type: 00 (Basic Style), Suffix: None, Indicator: None, Bracket: B (w/Bracket Included)

Piping adapter assembly - old style see E*00 - New Style , Easy maintenance , Detach equipment without removing piping , Assembles to FRLs by simply tightening screws , Available with a L and T type bracket, BRACKET-AMC310 ( B ), AIRLINE EQUIPMENT, AM NO SIZE RATPART, .11000 lb

Piping adapter assembly - old style see E*00 - New Style , Easy maintenance , Detach equipment without removing piping , Assembles to FRLs by simply tightening screws , Available with a L and T type bracket, BRACKET-AMC610 ( B ), AIRLINE EQUIPMENT, AM NO SIZE RATPART, .32560 lb

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)

Body Size: 40, Type: B (Regulator Type), Pipe Thread: F (G), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EC [EtherCAT®, (When Wireless Adapter is Connected, Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)