(Except for 1E to 3E) (Except for 1E to 3E) Refrigerant Coefficient of ozone depletion-Zero Model Air flow capacity Outlet air pressure dew point Rated inlet condition l/min(ANR) 50Hz 60Hz 100 200 310 500 740 1200 1650 310 500 740 110 220 350 570 810 1300 1820 350 570 810 IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E IDU3E IDU4E IDU6E Inlet air of normal temperature 35C Saturation 0.7MPa 10C

Mitsubishi Electric Corporation Yaskawa Electric Corporation LJ1H202PA-K 100W to 500 LJ1H202NA-K 100W to 500 LJ1H303PA-K 200W to 500 LJ1H303NA-K 200W to 500 Standard stroke (mm) and Speed (mm/s) Model Motor type 200 300 400 500 600 700 800 900 1000 1200 1500 Capacity 100 LG1H202SC 100W to 500 LG1H202PA 100W to 500 Standard motor LG1H202NA 100W to 500 [Tamagawa Seiki Co., Ltd.]

Mitsubishi Electric 30 guide 100W 0.02 Ground ball screw Corporation 1000 Yaskawa Electric 100W 0.05 Rolled ball screw Corporation Features 1 Simplified Selection Flow Chart Series LJ1/LG1 Page Standard stroke (mm) and Speed (mm/s) Nonstandard motor Model Standard motor Clean room Dust seal Deflection TSUBAKI 100 200 300 400 500 600 700 800 900 1000 1200 1500 CABLEVEYOR LJ1S101SC 88

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

Magnet: D (Built-in), Mounting: C (Single Clevis), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: D (Built-in), Mounting: D (Double Clevis), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: D (Built-in), Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: D (Built-in), Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: None, Mounting: C (Single Clevis), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: None, Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC11 (Dual Stroke, Single Rod)

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 4 pcs., Stroke Options: XC10 (Dual Stroke, Double Rod)

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards

Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards