Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 900mm, Bellows/Cushion: Cushion Both Sides
Magnet: None, Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 900mm, Bellows/Cushion: Cushion Both Sides
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
-3.5-W/K 3.5 PSI with Adjusting Knob RMW-900-10-W/K 10 PSI with Adjusting Knob RMW-900-30-W/K 30 PSI with Adjusting Knob RMW-900-60-W/K 60 PSI with Adjusting Knob RMW-900-90-W/K 90 PSI with Adjusting Knob
-3.5-W/K 3.5 PSI with Adjusting Knob RMW-900-10-W/K 10 PSI with Adjusting Knob RMW-900-30-W/K 30 PSI with Adjusting Knob RMW-900-60-W/K 60 PSI with Adjusting Knob RMW-900-90-W/K 90 PSI with Adjusting Knob
-3.5-W/K 3.5 PSI with Adjusting Knob RMW-900-10-W/K 10 PSI with Adjusting Knob RMW-900-30-W/K 30 PSI with Adjusting Knob RMW-900-60-W/K 60 PSI with Adjusting Knob RMW-900-90-W/K 90 PSI with Adjusting Knob
-3.5-W/K 3.5 PSI with Adjusting Knob RMW-900-10-W/K 10 PSI with Adjusting Knob RMW-900-30-W/K 30 PSI with Adjusting Knob RMW-900-60-W/K 60 PSI with Adjusting Knob RMW-900-90-W/K 90 PSI with Adjusting Knob
-3.5-W/K 3.5 PSI with Adjusting Knob RMW-900-10-W/K 10 PSI with Adjusting Knob RMW-900-30-W/K 30 PSI with Adjusting Knob RMW-900-60-W/K 60 PSI with Adjusting Knob RMW-900-90-W/K 90 PSI with Adjusting Knob
pressure insulation function Float switch 5,000 9,000 14-13-6 AIR OIL 8 3 32 to 2 DP lube ALD600/900 DP lube unit ALDU600/900 4 3 2,000 5,000 14-13-11 Centralized multiple lubrication Bracket Bracket panel (ALDU) Float switch 1, 2, 3 32 Float switch 5,000 14-13-15 Booster lube ALB900 Centralized multiple lubrication No pressure differential type 1 Reference) AL1000 = 7 cm3, AL2000 = 25 cm3
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: Air cushion on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5NT--Solid State, With Timer, 4 Wire NPN, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 5m, Number: 3 pcs.
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A34--Reed, DC Volt >5 <24, AC Volt <200, LED, Terminal, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A34--Reed, DC Volt >5 <24, AC Volt <200, LED, Terminal, Lead Wire or Prewied Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewied Connector: -, Number: -