SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-AN-20-J"

L G ZA F H K J ZX I B C E D A ZR ZM 2 x M3 countersunk head screw mounting hole ZMA ZQ ZH ZU ZFC10, 20 ZL Applicable tubing O.D.

25, 32 40, 50, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 6, 10 15, 20 25, 32 12, 16, 20 25, 32, 40 50, 63, 80 100 10, 16 20 25, 32 12, 16 20, 25 32, 40 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 20, 25 32, 40 50, 63 12, 16 20, 25 6, 10 16 20, 25, 32 40, 50 10, 15 25 6, 10 16 20, 25 32, 45 Bore size (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed Rubber

Ospeaified linearity can be ob'tained with an angular travel lrom 1o'to 30". A travel angle of aoDrox. 20' is most suitable. Example with serration ioint Example of cam installalion /<\ /+'.' l I " / Bearing \.'J RA side o Adjustment Span adjustment Span can be adjusted by rotating th span adjusting knob with the lock screw loosened.

SUP/EXH block assembly specifications 20 20 stations Note 1) Double wiring specifications: Single, double, 3 position and 4 position solenoid valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout.

Trigger input GND 8 4 Input/Output circuit 20 IZN10E Series Made to Order 1 This product is an individually applicable product. For details about the delivery time and price, please consult with SMC representative.

Note) D1: Max. diameter M5 x 0.8 10.4 8 14 8 14 17 9.8 13.4 9.8 13.4 17.6 20.5 22 23.5 24.5 25 11 15.5 12.5 15.5 20 17 20 25.5 22 24.5 24.5 25.5 20 29.5 20 29.5 38.5 31 38.5 45.5 41 45.5 45.5 50 16 16 4 1 8 M5 x 0.8 25.5 16 25.5 32.5 27 32.5 39 35 39 39 42 D1 1 8 1 4 1 8 1 4 3 8 1 4 3 8 3 8 1 2 6 12.8 17 L3 L2 17.6 28.5 M5 x 0.8 17 15.2 8 18.5 D2 25.2 20.6 25.2 25.2 29.5 22 22 19

-05DRS-C6 20 20 stations For special specifications, indicate separately by the manifold specification sheet.

2 x 3.4 33 IZH 30 30 52 46 44 26 17 11 40 5 8 x 3.4 20 26 12 2 x Hexagon socket head cap screw M3 x 6 (Accessory) Internal mounting Pivot mounting 21 33 (Mounting angle adjustable range) (90) 61 61 30 Pivoting bracket/IZN10-B2 20 3.4 56 64 28 20 (Mounting angle adjustablerange) 20 9.5 9 90 24 3.4 4 14 40 2 x Hexagon socket head cap screw M3 x 16 59 11 (Accessory) 18 457 IZN10 Series Dimensions

in 1 m increments from 1 m to 20 m.

Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.

Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.

CAT.ES13-7 A Exhaust Cleaner for Clean Rooms Series AMP An exhaust cleaner that can be used inside a clean room. Series AMP Exhaust Cleaner for Clean Rooms An exhaust cleaner that can be used inside a clean room Exhaust air cleanliness: Equivalent to Class 100 (Consult SMC in advance, as this will differ depending on the operating conditions.)

When selecting an exhaust cleaner, refer to the selection method shown below, as the selection method will differ for exhaust from actuator drive systems, etc., and exhaust from ejectors, etc.

In the ON condition an indicator LED will show, and any connected load will be powered. In the OFF condition, there will be no indicator LED and no power supplied to the load. An output showing such behavior is called switch output.

Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized. 3.

The apparent power in parentheses is for VXZ2232. 50 66(60) 20 60 57(51) 15 AC VXZ22 DC 50 93 25 60 79 20 AC VXZ23 DC JIS Symbol OUT IN 17-3-63 Applicable Fluids Check List Refer to pages 17-3-62 and -63 for models and specifications. Refer to pages 17-3-62 and -63 for models and specifications.

Model Exhaust Piping/Port location Port size Applicable P R 1 A,B P It A,B Valve NWsF5-20Common Side /Base Side/Base fop/ Valve %NPrF I %flPlf LNPIF %NPIF NVFSO20 DXT 156-20-1TA EXH relocation spacer NVV5F5-20 156-19-14 NW5F5-20 " Spacer is used when it is nscessary to exhaust from certain valves individually.

(Mounting position: Horizontal) W 1000 500 400 Allowable lateral load W (N) 300 Allowable kinetic energy 200 Piston speed 200 180 200 100 180 Piston speed Allowable kinetic energy 20 to 400mm/s 12.4J 50 40 30 (m1 + m2) V Kinetic energy E (J) = 2 m1: Weight of moving cylinder parts kg m2: Load weight kg V: Piston speed m/s 20 10 0 20 40 60 80 100 120 140 160 180 200 220 260 240 280 300 Kinetic

It cannot be used if connected in the opposite direction. 4.6-24 Series AME Dimensions: AME150 to AME350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4, 3/8

: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.