20 0.5 0.4 0.3 0.2 0.5 0.4 0.3 0.2 25 20 16 16 12 12 0.1 0.1 0 40 60 80 100 120 140 160 180 200 20 20 0 40 60 80 100 120 140 160 180 200 Overhang L (mm) Overhang L (mm) Graph (20) Stroke: Up to 150 stroke Graph (16) Stroke: Up to 150 stroke 10 20 10 20 2 3 4 5 2 3 4 5 Weight W (kg) Weight W (kg) 40 40 32 32 1 1 0.5 0.4 0.3 0.2 0.5 0.4 0.3 0.2 25 25 20 20 0.1 0 40 60 80 100 120 140 160 180
Both input and output sizes are shown for an input / output unit. In / Out size Input data "--" is displayed for an output unit. Displays input data value which is sent to an input unit or input / output unit. Output data "--" is displayed for an input unit.
Ambient temperature 0 to 40C (No freezing) Ambient humidity 35 to 65%RH (No condensation) Material Case: PBT Emitter: Tungsten Weight (Body only) Standard nozzle 200 g Bypass nozzle 250 g Standards/Directive CE (EMC directive, RoHS directive), UKCA Ambient humidity 20 to 80%RH Safety standards IEC 62368-1 *4 An AC cord included with an AC adapter is only for use in Japan.
The area of one pad can be divided to an equivalent area of multiple pads (n) as necessary, based on these forces and the shape of the load. Calculation Method: Pad Diameter A vacuum pad diameter with applied safety factor based on lifting orientation of workpiece (vertical or horizontal) can be derived from calculations or by using the Selection Graph shown below.
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use a valve with DC specifications.
Note 8) Min. operating pressure = 0.1 MPa Note 9) If a compact pressure switch is mounted later on, an elbow (R x Rc) is necessary. Mist separator and regulator are combined together. Filtration 0.3 m Space-saving and easy piping.
~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC Material Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Courtesy of Steven Engineering, Inc. !
H G I J K L A B C D E F M R Size Tolerance +0.058 0 -0.1 -0.2 -0.1 -0.2 -0.1 -0.3 -0.1 -0.3 AD-FI-20 AD-FI-25 AD-FI-32 AD-FI-40 +0.027 0 +0.027 0 +0.027 0 +0.027 0 9 9 16 16 36 38 55 55 16 18 22 22 9 9 12 12 20 25 32 40 10 10 15.5 15.5 20 20 24 24 14 14 20 20 M8 x 1.25 M10 x 1.25 M14 x 1.5 M16 x 1.5 20 25 32 40 46 46 56 64 28 30 40 43 60 60 80 88 22 22 30 30 16 16 16 24 10 10 12 12 30 30
20 2 pcs. 5 10 15 10 20 15 Auto Switch Mounting Bracket Part Nos.
CH2-4 has one output each. 4 Multi-channel Digital Sensor Monitor PSE200A Series 3-Screen Display IO-Link is an open communication interface technology between the sensor/ actuator and the I/O terminal that is an international standard, IEC61131-9.
, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 MM A F F S + Stroke H ZZ + Stroke (mm) P Bore size (mm) MM A NN D F G1 G2 S ZZ I H J N1 N2 NA TN TF 10 15 M12 x 1 4 M5 x 0.8 8 15 6 M4 x 0.7 65 101 18.5 28 16 11 20 16 16 15 M14 x 1 5 M5 x 0.8 10 15 6 M5 x 0.8 74 114 22 30 22 12 21 19.5 20 18 M20 x 1.5 8 Rc1/8 13 NPT1/8 25 G1/8 8.5 M8 x 1.25 97.5 151 31.5 40.5 28.5 20.5 33 29
20 25 20 20 20 25 40 50 63 80 40 50 63 80 S Bore size 40 40 50 63 80 50 63 80 B For 40 of A015, S type only Offset Arm position A015 A045 Offset 15 Offset 45 D1 Right D2 H R Center D1 D2 C H Left D1 D2 L H 192 Power Clamp Cylinder Series CKZT Cylinder Specifications 40 50 63 80 Bore size (mm) Action Double acting Fluid Air Proof pressure 1.2 MPa (174 psi) Max. operating pressure 0.8 MPa
Apply an appropriate tightening force during mounting.
Note) The minimum bending radius of the D sub connector cable is 20 mm. Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.
After washing the element, make sure the base seal is properly mounted. 500 A Vertical Suction Filter FHIA Series Dimensions Differential pressure indicator 16 B (34) F OUT Removal dimension K H F OUT D E C H Differential pressure indication switch FH FH 62 HOW (65) F IN 4 x I OUT A J G (mm) A B C D E F G H I J K Model Weight (kg) FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA
Jf Sl.W') GNOI~1 : ~EDiM,> I OIlC\ ~SlW< ::HJ1eIma ~ __ _ ___ J !... ___ _ _ J !... _ _ __ J Precautions Construction/ Parts List Piping (DBe sure to apply a wrench to the metal seclion (17mm) during piping. Never apply a wrench to the resin section of the main unit. , ::g}Clean tube fittings by air-blow (0 remove foreign matter from inside.
< II"", ~ ~ _ _ _ _ ...J p",,~ . ~~ pIy G NOIGomna l 1 _ _ .J 1>0'., s.uPply GNO " rm,nal ~ ~ _ _ ~ ~ _~ ~ ~ J f>ooo;ef lluppty GNOIEllmonal ~ ~ _ Construction { Parts List Precautions Installation Use of Toxic, Corrosive, or Flammable Gas Pressure sensor and fitting matenal of this switch J)Apply wrench only to the metal hex section is SUS630 and SUS304.
Body Needle V seal Lock nut Adjustment handle Insert bushing Nut Collar A 1 2 3 4 5 6 7 8 PFA PCTFE PTFE PVDF PVDF PFA PFA PFA Body class 2 y u y u B Dimensions A (B) (max.S) D H Port A 2 x G SMC (J) SMC C E F K Port B E A B C D E F G H J K S Model 48 60 72 LVN20 LVN30 LVN40 24 30 36 12 18 22 88 110 124 34.5 43 52 6 9 11 4 5 6 14 25 25 20 26 33 18 24 30 2.4 7.5 8.0 940 LQ1/LQ3/LVN/LQHB Series