(mm) L1 Manual override Stations n L1 L2 L3 L4 2 stations 135.5 125 100 17.5 3 4 5 6 7 8 9 10 stations (Press and turn for the locking type.)
L1 to L5 dimensions are the same as 10P type.
Allowable dynamic moment Model Mounting orientation LJ1H20 Actuator rating Load movement direction 8kg 500mm/s 600mm Work load Maximum speed Maximum stroke 600 L1 (mm) 400 a = 1000 Pitching Yawing Vertical Vertical m a a = 2000 a = 3000 200 LJ1H2022PA-K (Power supply voltage 200VAC) L1 Mep 0 5 10 15 Transfer load m (kg) When an actuator is operated under conditions that exceed the lines in
) 35 35 L Dimension Formula L n 10 9 8 7 6 5 4 3 1 2 P , R1, R2 port n: Stations L1 = 56n + 64 L2 = 56n + 80 n: Stations L1 = 56n + 90 L2 = 56n + 106 L1 624 568 512 456 400 344 288 232 120 176 1/2 L2 640 584 528 472 416 360 304 248 136 192 L1 650 594 538 482 426 370 314 258 146 202 3/4 L2 666 610 554 498 442 386 330 274 162 218 ( ): 3/4 Dimensions inside are for rubber seals. 3-10-28 29 ISO
L1, L2 max. overhang = 45 mm w Confirm that L1 and L2 are lower than the max. overhang. L1 = 20 mm and L2 = 30 mm OK (L1, L2 max. overhang = 45 mm) Selection method q Find the max. overhang of L1 and L2 from the selection graph. L1: Find the L at an operating pressure of 0.5 MPa from the graph, and multiply it by 1/2.
except A, L and L1 are same as front flange type.
A A1 RR1 A1 E1 L1 MM RR1 U1 NZ L Part no.
L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max.
78.5 42.5 DIN rail holding screw (For DIN rail mounting) (Station n1) (Station 1) (Station 1) (Station n2) Light/surge voltage suppressor Individual SUP spacer Individual EXH spacer 63.5 60 52.5 12 (For DIN rail mounting) (7.5) n1 = Valve stations n2 = Input block stations L2 = L1 10.5 L3 = 16 x n1 + 60 L4 = L3 + 81 + 21 x n2 L5 = (L1 L4)/2 L6 = 16 x n1 + 48 L7 = 21 x n2 + 81.5 L1: DIN
In this case, please note that dimensions, L1 and L2 on pages 160 and 161 may vary slightly.) For other components, refer to the SY series of the WEB catalog.
CRB2 CRB2 Q1 = M Q1 = M CRB1 L1 = L1 = MSU L1 L1 Q1 Q1 CRJ Not available for size 10 Not available for size 10 The maximum dimension L1 is, as a rule, twice the thread size. (Example) For M5: L1 max. = 10 mm The maximum dimension L1 is, as a rule, twice the thread size.
Allowable dynamic moment Model Mounting orientation LJ1H20 Actuator rating Load movement direction 8kg 500mm/s 600mm Work load Maximum speed Maximum stroke 600 400 L1 (mm) a = 1000 Pitching Yawing Vertical Vertical m a a = 2000 a = 3000 200 LJ1H2022PA-K (Power supply voltage 200VAC) L1 Mep 0 5 10 15 Transfer load m (kg) When an actuator is operated under conditions that exceed the lines in
Slave unit 75 Slave unit 03 Slave unit 01 Master unit ZW-31LM SI unit Master unit SI unit Master unit SI unit SI unit SHIELD SG L2 L1 SHIELD SG L2 L1 SHIELD SG L2 L1 SG L2 L1 + + FG + + FG + + + + + + SHIELD FG FG + Twisted pair wire with shield Class 3 ground Class 3 ground Class 3 ground Class 3 ground FG FG b) 3 wire type Wiring does not include signal ground line (SG).
= 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1.
Formula: L1 = 16n + 57, L2 = 16n + 176 (For one input block.
P = 10.5 15.5 L1 L2 4.5 (Station 1) (Station n) 15.5 (Light/surge voltage suppressor) (Light/surge voltage suppressor) + + + + + + + + + + B B 20 15 5 A A B B 20 1 5 15 (Pitch) P = 10.5 M5 x 0.8 (A, B port) A A One-touch fitting (A, B port) Applicable tubing O.D.: 4 and 5/32" 17.5 (Pitch) P = 10.5 18 1.5 SS5YJ3-32,S32Stations -M5 Stations n L1 L2 10-SS5YJ3-32,S32Stations -C4 3 52 44 6 83.5
Slave unit 75 Slave unit 03 Slave unit 01 Master unit ZW-31LM SI unit Master unit SI unit Master unit SI unit SI unit SHIELD SG L2 L1 SHIELD SG L2 L1 SHIELD SG L2 L1 SG L2 L1 + + FG + + FG + + + + + + SHIELD FG FG + Twisted pair wire with shield Type 3 ground Type 3 ground Type 3 ground Type 3 ground FG FG b) 3-wire type Wiring does not include signal ground line (SG).
L1 L1 = L1 = L1 L1 = Q1 = M Q1 = M Q1 = M Q1 = M L1= L1 L1= Q1 = M Q1 K axis Q1 T axis (mm) Q1 Q1 L1 L1 Size Thread M 3 x 0.5 M 4 x 0.7 M 5 x 0.8 M 6 x 1 M 8 x 1.25 M10 x 1.5 Rc 1/8 Q1 J axis Z axis (mm) 15 20 30 40 10 (mm) Size Thread M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 4.2 5 6.8 8.5 8.2 2.5 2.5 3.3 2.5 3.3 4.2 5 20 10 15 40 30 Size Thread M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 3.3
Allowable dynamic moment Model Mounting orientation LJ1H20 Actuator rating Load movement direction 8kg 500mm/s 600mm Work load Maximum speed Maximum stroke 600 400 L1 (mm) a = 1000 Pitching Yawing Vertical Vertical m a a = 2000 a = 3000 200 LJ1H2022PA-K (Power supply voltage 200VAC) L1 Mep 0 5 10 15 Transfer load m (kg) When an actuator is operated under conditions that exceed the lines in
U side mounting 17.5 17.5 3 1/8" PE. port 3 1/8" PE. port 38 70 38 53 Dimensions Formula: L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) Dimensions Formula: L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) n L 1 2 3 4 5 6 7 8 L1 88 113 138 163 188 213 238 263 L2 101 126 151 176 201 226 251 276 n L 1 2 3 4 5 6 7 8 L1 88 113 138 163 188 213 238 263 L2 101 126