Communication: None, Options: Circulating Fluid Automatic Recovery, Cooling Capacity: -, Temperature Set Range: -, Option: -
Cooling Capacity: 002 (2 kW), Communication: None, Option: Z (Circulating Fluid Automatic Recovery)
Cooling Capacity: 004 (4 kW), Communication: None, Option: Z (Circulating Fluid Automatic Recovery)
The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled
Circulating Fluid: Clear/Deionized Water, 10 to 60°C, Option: -
Circulating Fluid: Fluorinated Fluids, -20 to 90°C, Option: -
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket: None
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal,
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: B (Out 1: PNP, Out 2: Flow Rate: PNP, Temp.: None, Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket:
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature