Model: High Air Inlet Temp, 55°C, Applicable Dryer: IDU55E
Adapter for converting thread type of an IN/Out fitting for air dryers from Rc to NPT For converting thread type of an IN/Out fitting for air dryers from Rc to NPT ; Copper alloy
Adapter for converting thread type of an IN/Out fitting for air dryers from Rc to NPT For converting thread type of an IN/Out fitting for air dryers from Rc to NPT ; Copper alloy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Applicable dryers: IDF1E TO 75E, IDF120D to
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. For power supply and voltage other than standard
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. For power supply and voltage other than standard
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Applicable dryers: IDF1E TO 75E, IDF120D to
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Dedicated base for integrating transformer
IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Dedicated base for integrating transformer
Refrigerated air dryer that protects pneumatic equipment from moisture.Features · Removes the vapor from the moist compressed air delivered by the compressor and prevents it from causing the pneumatic equipment to fail.· Improved corrosion resistance with the use of stainless-steel heat exchanger.
Wait at least 3 minutes from stopping air dryer operation before starting the next operation.
If operation is restarted within 3 minutes, the protection circuit may be activated and the light may go out, resulting in operation failure.
Frequent ON/OFF of the product may result in malfunction.
The auto drains of the following models have been changed: IDF1E to 75E, IDU3E to 75E, IDH(A), and IDFA(IDFB)3E to 75E series.
Dryers produced from March 2019 onward feature the new auto drain with a different part number and shape.
The new and old auto drains are not interchangeable.
Contact SMC for the auto drain part number of option “K” (medium pressure specification) as well
Refer to the operation manual for details.
The IDF series operation manual can be found here.