(Refer to q shown in the figure below.) If the lock plate is not locked completely, the pad may drop due to the vibration or load during operation. q ZA Holder y ZX Non-rotating hole Plate ZM 3. To ensure the safety, be sure to mount the lock screw on the lock plate before use. (Refer to w shown in the figure below.)
Port size q Seal order no. r Seal order no. t Seal order no.
Note 2) The seal is for 40 m and 80 m elements. 784 Vacuum Filter AFJ20 to AFJ40 Series Dimensions AFJ20 N T J M D U Bracket (Option) S SP R ZCUK C B V Q IN OUT AMJ AFJ AFJ 2 x P (Port size) AMV ZH -X185 Related Products Clearance for maintenance G A AFJ30, AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications
Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 707 Series ARP20/30/40 Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option
Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 765 ARP20/30/40 Series Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option
When used as a switch output device Setting of NPN open collector 2 outputs Setting of PNP open collector 2 outputs Brown DC(+) q Brown DC(+) q Load Black OUT1 r Black OUT1 r Load Main circuit Main circuit + + 12 to 24 VDC 12 to 24 VDC White OUT2 w White OUT2 w Load Load Blue DC() e Blue DC() e When used as an IO-Link device Brown L+ q L+ Black C/Q r Main circuit C/Q IO-Link master White
2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !3 Open Component Parts Component Parts Note No. q Description Material Aluminum alloy Description Material Note No. Body Bushing B Hard anodized Sintered alloy steel o !0 !1 !2 !3 !4 !5 !
Standard type (through hole, double end tapped common)/RQB, RDQB 2-M5 x 0.8 (port size) 2-cushion needle 2 x 4-9 depth of counter bore 7 H effective thread depth C E1 E2 Q F 4-5.4 through D M E 1 Flat washer 4 pcs.
Snap ring Type C 8 for axis Type C 10 for axis Type C 10 for axis Type C 14 for axis m 1.5 1.25 1.25 1.75 t 0.9 1.15 1.15 1.15 Part no.
Snap ring Type C 8 for axis Type C 10 for axis Type C 10 for axis Type C 14 for axis m 1.5 1.25 1.25 1.75 t 0.9 1.15 1.15 1.15 Part no.
135 180 4-11 225 (266) (60) AIR VENT G 1/4 q q A (43) OUT IN e e 150 r B t 120 327 188 (519) w w 84 OUT 2-R 1 r IN 53 DRAIN G 1/4 Note Parts list Dimensions (mm) A B No.
Fittings & Tubing Air Cylinders Rotary Actuators Bracket (Option) Bracket (Option) R R V Q V Q IN OUT B C IN OUT Clearance for maintenance G B C 2 x P (Port size) 2 x P (Port size) Hexagon width across flats 14 1/8 Drain Hexagon width across flats 17 1/4 E A Clearance for maintenance G Drain A AF50/60-A 1021J D M U S N T Bracket (Option) R V Q C B IN OUT 2 x P (Port size) Hexagon width across
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !4 Open condition Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts Note Note No. q Description Material No. Description Material Bushing B !
C: With auto drain (N.C.) N.C. auto drain not available for AM650.
DC+ 1 Brown q N.C. 2 Not used w DC 3 Blue e IN: 1 to 5 V 4 White r Power supply/Output connector (8P) Power supply/Output connector (accessory) i u y t r e w q Pin No. Pin no. Terminal 7 Green CH4_OUT1 8 Yellow N.C.
C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5
Flow Characteristics Type 21P Flow characteristics Port size 14/2 (PA/B) 4/25/3 (A/BR) Effective area (mm2) C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 1(P), 5/3(R) port 2(B), 4(A) port Manifold Body ported for internal pilot SS5YJ3-21P SYJ323 1/8 M3 x 0.5 0.9 SS5YJ3-32P-M5 SS5YJ3-32P-C4 Base mounted for internal pilot 0.25 0.25 0.19 0.18 0.060 0.059 0.32 0.3 0.25 0.27 0.077 0.075 M5 x 0.8
(Refer to graph A) No AW AMR AWM Graph C: The balance completion time Yes AWD 5 ITV No Is the cylinder speed appropriate? (Refer to graph B) 4 VBA Completion time (sec) 3 VE Yes VY 2 Use graph C as a guide for the balance completion time.
Disassembly 1) After loosening the screw q, then if the housing r is pulled in the direction of the screw, the connector will be removed from the body of equipment (solenoid, etc.). 2) Pull out the screw q, then remove the gasket or . 3) On the bottom part of the terminal block e, theres a cut-off part (indication of an arrow) .