SMC Corporation of America
Elite Part Number Search
Search Results "ISE1-01-14"

Function selection mode ON OFF Front protective cover (Model: ZS-27-01) Connector Connecting / Disconnecting When mounting the connector, insert it straight into the socket, holding the lever and connector body, and push the connector until the lever hooks into the housing, and locks.

Body Size: 2 (1/8, 14), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 08 (ΓΈ8), Seal: S (with Sealant)

Series: 5 (JSY5000), Type: 40 (Side Ported), Valve Stations: 14 Stations, P,E Port Entry: D (D Side), A,B Port Size: 01 (1/8), Thread Size: N (NPT)

HEF002-A6 4-1 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2022 SMC Corporation All Rights Reserved

INR-244-831 4-1 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2021 SMC Corporation All Rights Reserved

This is a legacy product, and replaced byISE20B-X-M-01-W-X500, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .35825 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

pressure (OpenClosed) 0.5 Secondary pressure MPa 0.4 0.3 0.2 Type Y DIN terminal 0.1 0 0.6 0.1 0.2 0.3 0.4 0.5 0.7 0.8 0.9 1.0 Primary pressure MPa Needle valve flow characteristics Symbol Conditions: Primary pressure 0.5MPa 1800 2000 AV5000 1600 2 1(P) 2(A) 1400 Air flow l/min (ANR) AV4000 1 1200 1000 3(R) 800 AV3000 600 AV2000 400 Accessories/Pressure gauge 200 0 Pressure gauge G36-10-01

Applicable power supply voltage AC 100 Solenoid valve combination symbol Pilot valve symbol Nil Y Nil Nil Y Nil Nil Nil AC 200 AC 110 AC 220 DC 24 DC 12 K1 K1 K2 J1 J1 J2 Q1 Q2 q w e r t y u i Combinations (1) to (8) in the above table are the only possible options. 2 Series ZQ Compact Vacuum Ejector How to Order ZZQ1 08 B B S Manifold Pilot exhaust port location Number of stations Note) 01

-5VEX-OMO0001 3 VEX1 3 Series 0 ON-OFF (AF ) (AMAFM ) (P.2.3) [1 P][1P] PE ( ( ( ( ) ) ) ) IR2000 VEX 33 ITV VY 11 (0.5MPa ) (0.1MPa ), 2 Nm 1/6 MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa -6VEX-OMO0001 3 VEX1 3 Series 0 +0.1MPa 2 PE(ASN2-M5) 0.1MPa P1 O M5 P1 O VEX1-A30-3 O P1 P1 P1 M5 -7VEX-OMO0001 (PE) Best Pneumatics No. () VEX1333-03 G36-4-01

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. or longer simultaneously.

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the pressure switch body with a spanner. longer simultaneously, the main display shows [-], and the reset to zero.

Piping specification: -01, -N01 After hand tightening, hold the hexagonal spanner flats of the pressure port with a spanner, and tighten with 2 to 3 rotations. As a reference, the tightening torque is 3 to 5 Nm. When tightening, do not hold the Z/ISE20 body with a spanner. Pressure second or longer simultaneously.

Maintenance Bracket A or D(Model: ZS-24-A/ZS-24-D) Bracket B (Model: ZS-24-B) [01/N01 type] [W1/WF1 type] Operator How to reset the product after power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing.

-15No.VFR2000-OMM0001 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2009 SMC Corporation All Rights Reserved No.VFR2000-OMM0001

This is a legacy product, and replaced byZSE20BF-T-01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .24738 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

This is a legacy product, and replaced byISE20B-V-01-W-X500, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .30602 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

This is a legacy product, and replaced byISE20B-Y-01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .26054 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

This is a legacy product, and replaced byISE20B-Y-01-W-X505, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .21830 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay

This is a legacy product, and replaced byZSE20B-T-01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .25015 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator