Grommet type 16.5 3 7 15 21 2-3.4 mounting hole Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150 (Lead wire AWG#26) 22 5 6 22 20.5 3 2 11 1 7 6 5 12 12.3 12 25 M5 x 0.8 3 (EXH) port M5 x 0.8 2 (OUT) port M5 x 0.8 1 (SUP) port S070B-C-M5 Plug lead type 0.1 W with

One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.

Option (1) D C S Without option With locking mechanism With cancel cap With lever detection switch Action (2) D B T Double acting (1) The options can be combined, provided that the priority order is indicated as D, C, S.

1 1 C G LJ1 10 S W X10 Guide type Slider guide S X10 Non-standard motor Series Limit switch Series 10 Series 20 Series 30 10 20 30 Cable entry direction Nil None B contact specification 2 pcs.

Accelerating torque calculation (Example) (Example) Friction coefficient Ta = I x (Nm) Mass m F = mg Clamp F F I : Inertial moment Static torque calculation Movement Load Refer to features page 5. : Angular acceleration = (rad/s) Tf = F x l (Nm) g = 9.8m / s F: Pressing force (N) l l Static torque calculation 2 Load t2 Ts = F x l (Nm) Lever : Rotation angle (rad) t : Rotation time

: 0.5MPa SRP1-M5 Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure

: 0.5MPa SRP1-M5 Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure

Effective area (mm2) Weight (g) A L M Model M5, UNF10-32> AKH04-M5 AKH04-01S AKH06-M5 AKH06-01S AKH06-02S AKH08-01S AKH08-02S AKH08-03S AKH10-02S AKH10-03S AKH10-04S AKH12-03S AKH12-04S 8 10 M5 x 0.8 1/8 M5 x 0.8 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 3/8 1/2 24.3 24.6 25.8 26.9 30 31.7 21.2 20.6 22.2 22.9 24 27.7 36 35.5 48.3 40.8 41.3 54 46.5 5 10 4 2.8 12.7 Applicable tubing 2.8 6.5 6.5

Accelerating torque calculation (Example) (Example) Friction coefficient Ta = I x (Nm) Mass m F = mg Clamp F F I : Inertial moment Static torque calculation Movement Load Refer to features page 5. : Angular acceleration = (rad/s) Tf = F x l (Nm) g = 9.8m / s F: Pressing force (N) l l Static torque calculation 2 Load t2 Ts = F x l (Nm) Lever : Rotation angle (rad) t : Rotation time

Digital Flow Switch Unit Specifications Detection type Heat type Measured flow range 50 to 500 L/min 5 to 100 L/min Minimum unit setting 5 L/min 1 L/min Accumulated pulse flow rate exchange value (Pulse width: 50 [ms]) 5 L/pulse 1 L/pulse Accumulated flow range 0 to 9 L 5% F.S. or less (15 to 35C: Based on 25C) Linearity 2% F.S. or less Repeatability 5% F.S. or less (15 to 35C: Based on 25C

VXS VXS VXB VXE (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + T When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + T Conversion with sonic conductance C: VXP VXR VXH VXF VX3 VXA S = 5.0 x C(5) Q : Air flow rate[L/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream

) rubber hose 12 10 Cylinder bore size 40 9 Flow rate (l/min) 5 8 Cylinder bore size 32 7 6 Cylinder bore size 25 4 (steel pipe I.D.) 5(approx. 4.5) 4 Cylinder bore size 20 3 2 7 6 5 4 3 2 20 30 40 50 60 80 100 200 300 2.8 General range of rubber hose (max. 5m/s) General range of steel pipe (max. 4.5m/s) Flow velocity inside pipe (m/s) Piston speed (mm/s) How to read the chart: Example) The

Effective area (mm) Weight g A M5, UNF10-32> H L M Model (Width across flats) AKH04-M5 AKH04-01S AKH06-M5 AKH06-01S AKH06-02S AKH08-01S AKH08-02S AKH08-03S AKH10-02S AKH10-03S AKH10-04S AKH12-03S AKH12-04S 8 10 M5 x 0.8 1/8 M5 x 0.8 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 3/8 1/2 24.3 24.6 25.8 26.9 30 31.7 21.2 20.6 22.2 22.9 24 27.7 36 35.5 48.3 40.8 41.3 54 46.5 5 10 Applicable tubing 2.8

min Discharge rate l/min Discharge rate l/min PB1000 Air consumption Selection from flow rate characteristic graphs Required specification example: Find the pilot air pressure and pilot air consumption for a discharge rate of 600ml/min and a total lifting range of 15m.

min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.

D1 D2 L A M M5, M6 Nylon Urethane M5 0.8 M6 1.0 KXH04-M5 KXH04-M6 KXH04-01S KXH06-M5 KXH06-M6 KXH06-01S KXH06-02S KXH08-01S KXH08-02S KXH08-03S KXH10-02S KXH10-03S KXH10-04S KXH12-03S KXH12-04S 38.5 11 13 39 35 8 10.4 2.5 4.0 4.0 16 4 1 8 M5 0.8 M6 1.0 40 39.5 40 42 45 46 49 50 58 59 62 60 63 16 36 12 2.5 3 4.0 4.0 5.6 5.6 15 8 36 6 12.8 15 17 1 8 1 4 1 8 38 39 42 43 44 20 26 28 34 42 68

Effective area (mm) Weight g A M5, UNF10-32> H L M Model (Width across flats) AKH04-M5 AKH04-01S AKH06-M5 AKH06-01S AKH06-02S AKH08-01S AKH08-02S AKH08-03S AKH10-02S AKH10-03S AKH10-04S AKH12-03S AKH12-04S 8 10 M5 x 0.8 1/8 M5 x 0.8 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 3/8 1/2 24.3 24.6 25.8 26.9 30 31.7 21.2 20.6 22.2 22.9 24 27.7 36 35.5 48.3 40.8 41.3 54 46.5 5 10 Applicable tubing 2.8