Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 01 (1 Station), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
PF-OMK0003CN-E PFMV505 PFMV510 PFMV530 PFMV505F PFMV510F PFMV530F N2 (JIS B8392-1 1.1.21.6.2ISO8573-1 1.1.21.6.2) 2 2 2 () 00.5 01 03 -0.50.5 -11 -33 1 L/min L/min L/min L/min L/min L/min 2F.S. 3 2F.S.(1535 ) (25) 5F.S.(050 ) 2F.S.(0300 kPa) 5F.S.(-700 kPa) (0kPa 4) -70300 kPa -100400 kPa 500 kPa 5 15 V 5 ms 1 k DC1224 V10(p-p) 10() 16 mA IP40 050 () 050 -1060 () 3585R.H
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
Table 1 Moment of inertia Size Allowable kinetic energy (J) 10 0.00015 15 0.00025 20 0.0004 30 0.015 40 0.03 How to calculate the load energy E : Kinetic energy (J) I : Moment of inertia (kg m Speed (rad/s) : Rotation angle (rad) 1803.14 rad t : Rotation time (s) 1 E = I 2 2 2 = t Table 2 Safety operable rotation time adjustment range Size Rotation time ( s / 90) 10 0.03 to 0.5 15
Note 1) 25P Note 1) 26P 20P Side entry Side entry Side entry Connector entry direction Connector entry direction Connector entry direction P. 523 P. 527 P. 531 P. 535 Top entry Side entry Top entry Top entry Side entry Side entry Without cable Without cable Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) Without cable S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 0 1 2 3 U0 U1 U2
Flow Direction Symbols on Body How to Order Meter-out type Meter-in type Indication symbol 2 1 01 06 2 AS 1 F E S K Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Symbol Applicable tubing O.D.
G H F SMC P . U S Can be locked with a padlock in the exhaust condition. E C Padlock mounting position C D D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SUP SUP . A OUT IN A OUT IN 1 2 B 3 B EXH. EXH.
G SMC H F P . U S Can be locked with a padlock in the exhaust condition. E C Padlock mounting position C D D SUP SUP. A OUT IN A OUT IN 1 2 3 B B EXH. EXH.
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)
DENMARK SMC Pneumatik A/S ESTONIA SMC Pneumatics Estonia FINLAND SMC Pneumatics Finland OY FRANCE SMC Pneumatique S.A. GERMANY SMC Pneumatik GmbH GREEK SMC Hellas EPE HUNGARY SMC Hungary Ipari Automatizlsi Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A.
Nozzle Type Ionizer IZN10E Series How to Order Energy saving static neutralization nozzle 01 P IZN10E 06 Z B1 High flow rate nozzle Female threads for piping High frequency AC nozzle type Bracket Nozzle type Symbol Type Part no.
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type)
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Connector Type: S (M12 Connector Type)