SMC Corporation of America
Elite Part Number Search
Search Results "ITV2340-24"

The length is 24 when any of the following auto switches are used: D-90/90A/S99(V)/T99/S9P(V) The length is 30 when any of the following auto switches are used: D-97/93A 2.

Example: Power supply is 24 VOG. Example: Load impedance IS 3 kn. load voltage will decrease when in the ON state. the load voltage will OFF.

D D 10 14 B B 24 31 A 8 11 A 7 10 Model ZP3-T035U;K3-B3 ZP3-T035U;K6-B3 Note) ;in the table indicates the pad material "N, S, U, F, GN, GS."

-X417 Fine stroke adjustment range (mm) -X417 (one side) Adjustment range MY1MW MY1CW -X416 (one side) Adjustment range Slider (Piston yoke) Stroke adjusting unit Bore size (mm) Spacer lengths Spacer length MY1MW MY1CW 5.6 to 11.2 6 to 12 11.5 to 23 12 to 24 16 to 32 20 to 40 25 to 50 11.2 12 23 24 32 40 50 5.6 6 11.5 12 16 20 25 11.2 to 16.8 12 to 18 23 to 34.5 24 to 36 32 to 48 40 to 60

A33 A34 A44 G39 K39 Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V Relay, PLC Reed switch Solid state switch 100 V, 200 V Yes Yes 12 V PLC Terminal conduit 24 V 2-wire 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 24 V Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2

LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC

Power for SI Unit/Input Block: 24 VDC 20%, 1.1 A or less Inside of SI Unit: 0.1 A or less Input block: 1 A or less (Depending on number of connecting sensors and specifications) Power for solenoid valve: 24 VDC +10%/-5%, 2 A or less (Depending on number of solenoid valve station and specifications) Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge

Page 24 Distributed by Power Aire, Inc. (800) 526-7661

MGF MGPWL, MGPWA Common Dimensions (mm) Standard stroke (mm) Bore size (mm) B C DA DB FA FB G GA GB H J K L MM ML MGZ 20 25 32 40 50 63 34 35 37 41 42 49 10 10 14 14 18 18 10 13 16 16 20 20 7.5 9 10 10 12.5 12.5 3 3 5 5 6 6 36 42 48 54 64 78 9.9 10.3 11.4 13.5 14 15.5 7.5 8.7 9 10.5 11.1 13.5 137 157 190 206 258 286 18 21 24 27 32 39 18 21 24 27 32 39 24 30 34 40 46 58 M5 x 0.8 M6 x 1 M8

A33 A34 A44 G39 K39 Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V Relay, PLC Reed switch Solid state switch 100 V, 200 V Yes Yes 12 V PLC Terminal conduit 24 V 2-wire 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 24 V Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2

E Port size Octagon C T-interface B Center of F.R.L. body A D Model Port size A B C D E Applicable model Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B Y210-01 1/8 15 42 32 28 19 AC20, AC20B AC20C Y210-02 1/4 AC25, AC25B AC25C, AC30 AC30B, AC30C Y310-02 1/4 Y310-01 1/8 15 53 39 30 19 Y410-02 1/4 19 62 44 36 24 AC40, AC40B AC40C Y410-03 3/8 Caution in Mounting Y510-02 1/4 19 66 46 44 24 AC40-06

21 M16 x 2 20 9.5 11.5 M12 x 1.75 24 63 95 77 18 35.5 31 27 M20 x 2.5 24 11.5 14 M16 x 2 24 80 109 88 21 45 39 36 M27 x 3 33 15 17 M18 x 2.5 27 100 132 106 26 56 48 41 M30 x 3.5 36 17.5 22 M20 x 2.5 30 Rod end male threads a b c e f g h Bore size (mm) X & Y dimensions Part no. suffix -XC62 20 None 12 14 M8 x 1 5.5 10 24 67 -XC62R 25 4 places on front side 14.5 17 M10 x 1.25 6.5 12 28 73

10 7 19 25 J 17 27 40 50 60 K 22.5 32.5 42.5 52.5 62.5 Z 41.5 51.5 61.5 83.5 99.5 M 42 52 62 84 100 ZZ 48 58 68 90 106 MXS6-10 MXS6-20 MXS6-30 MXS6-40 MXS6-50 54 Air Slide Table MXS Series Dimensions MXS 6 With buffer (6) MXS6F 24 10 28 2-M3 x 0.5 thread 5 deep 22 0.5 19 Dimensions not indicated are the same as basic type.

(such as static electricity. (2) Check if the power supply voltage System error is in the range 24 VDC 10%. (Er0, 4, 6, 7, 8 or 9) is displayed. (2) Supply power in the range 24 VDC 10%. HHH is 6 displayed. (1) Reset applied pressure (1) Check that the pressure is not to a level within the set pressure range.

24 144.5 103 53 31 11 18 depth 6 12.5 40 292.5 121 25 10 45 50 98 25 110 138 24 35 171.5 132 54.5 38 13 20 depth 6 12.5 P (Piping port) Model Stroke R S T V W WB XA XB Y 30 QB 8 U 5.5 Model Nil TN TF RS2H50 RS2H63 RS2H80 40 21 2 15.5 73 32 5 15.8 10 24 RS2H50 RS2H63 RS2H80 NPT1/8 G1/8 Rc1/8 30 8.5 47 24.5 3.5 6.4 16 87.5 38.5 5 18.7 10 24 Rc1/4 NPT1/4 G1/4 40 10 54 31 3 6.7 19 109 49 6

or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal

VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC * DC specification of type D and DO is only available with 12 and 24 VDC.

(Refer to Precautions on page 16-2-24 for details.)

T02 1/4NPT S Y M B O L S T Y P E I N L E T P O R T B Box type D Body type 06 6mm Tube 08 8mm Tube 01 Rc1/8 07 1/4 Tube 09 5/16 Tube T01 1/8NPT V A C U U M P R E S S U R E S 660mm Hg L 360mm Hg D I M E N S I O N S M A X I M U M S U C T I O N F L O W R AT E/ A I R C O N S U M P T I O N U N I T (ln/min) Nozzle Diameter mm Specifications Max Vacuum Pressure* 0.5 0.7 1.0 1.3 mmHg (Torr) 5 12 24

M15 x 1.5 4 10 20 23.5 17 15 27 30.5 24 5 14.5 19 11.5 15 19 4.5 M22 x 1.5 5 10 20.5 25 17.5 15 27 31.5 24 Note) E and F should be machined in a concentric manner.