x 0.8 8 40 M5 x 0.8 8 Minimum lead wire bending radius 10 Auto switch F Q H thread effective depth C 4 x N through 2 x M5 x 0.8 (Port size) I D E M Z A + Stroke B + Stroke L W G M K J 25 to 40 Minimum lead wire bending radius 10 Auto switch H thread effective depth C 4 x N through F Q 2 x M5 x 0.8 (Port size) I D E M Z A + Stroke B + Stroke L W E M K J Standard [mm] Bore size Stroke range
2 2-8 counterbore with depth 4.3 2 2-5.5 through 2 2-9.5 counterbore with depth 5.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2-M4 0.7 with depth 6 15 2-M5 0.8 54 19 70 52 17 8.5 42 25 5 10 2.5 20 8 9.5 38 57.5 9 2-M4 0.7 with depth 6 20 2-M5 0.8 62 24 84 60 22 11 50 29 6 12 4.5 25 10 12 45 67.5 9 2-M5 0.8 with depth 7.5
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 M5 x 0.8 M3 x 0.5 10.5 16 M6 x 1.0 M4 x 0.7 11.5 20 M8 x 1.25 M5 x 0.8 13.5 25 M10 x 1.25 M6 x 1.0 16.5 30, 40 M14 x 1.5 M8 x 1.25 22.5 Clevis pin d Dd9 m m l t L t Applicable bore size (mm) Applicable snap ring Part no.
2 2-8 counterbore with depth 4.3 2 2-5.5 through 2 2-9.5 counterbore with depth 5.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2-M4 0.7 with depth 6 15 2-M5 0.8 54 19 70 52 17 8.5 42 25 5 10 2.5 20 8 9.5 38 57.5 9 2-M4 0.7 with depth 6 20 2-M5 0.8 62 24 84 60 22 11 50 29 6 12 4.5 25 10 12 45 67.5 9 2-M5 0.8 with depth 7.5
V100-49-15 D V115 Light/surge voltage suppressor Rated voltage Nil Without light/surge voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) S Z 5 24 VDC 6 12 VDC Cable length 1 100 VAC 50/60 Hz 1 2 3 4 7 300 mm 500 mm 1000 mm 2000 mm 5000 mm 2 200 VAC 50/60 Hz DOZ is not available.
Usage 2 x 3 CK-P04 Knuckle pin Clevis pin 4 4 57 Note) Cotter pins and flat washers are attached to the pin as a standard. 430 CK1 Series Options Limit Switch Mounting Base/Dog Fitting 50 75 Material: Rolled steel 4 x M5 x 0.8 17.3 58.7 5 30.2 Part no.
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal
Remove these screws Remove these screws Fig. 3-2 Foot mounting screws 2) Then tighten M5 screws (bolts) or equivalent into 4 holes sized to 7mm on the parts marked with arrow for mounting.
ms01000ms TimeOutVal_Setting int 500 ms01000ms 22 - Component CLOSE Component Success: Close and Check Signal False Close and Check Signal True ON Fail: Open and Check Signal true Wrong_value: WaitTime Setting TimeOutVal_Setting bool false / Close and Check Signal true ON false WaitTime Setting int 500 ms01000ms TimeOutVal_Setting int 500 ms01000ms 23 - 5-4 1. 2. 3. 4. 1.(
Section A (L: approx. 2900) 2-4.4 Mounting hole MULTISTAGE EJECTOR 76 52 8 27 178.5 5 4.5 Section A with digital vacuum pressure switch (40) (N)ZL212-E (ZSE4) (N)ZL212-EB (ZSE4B) (N)ZL212-EE (ZSE4E) (2) (1.6) 4-M5 x 0.8 Thread depth 6 (mounting hole) 73 87 12
TimeOutVal_Setting int 500 Timeout setting of checking the auto switch signal (Unit: ms, Range: 0..1000ms) Note) It will only be appeared when the Advanced setting is selected. 22 - Component Release node This component is used to release the workpiece by the gripper.
Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.
Lubrication Equipment Applicable oil viscosity (cSt (3)(40C)) Application Port Size Bowl capacity (cm3) Option Page Series (1) M5 to 1 Lubricator AL1000-6000 Individual lubrication Bracket 1,000cm3 Tank Float switch 130 1,000 32 1.17-2 32 1 1/4 to 2 Large flow lubricator AL800, 900 Individual lubrication 500 1,000 1.17-8 1,000cm3 Tank Float switch (2) 5,000 9,000 1.17-11 32 Auto Feed Lube
Example) Bolt M5 x 50l 4 pcs.
-100.0100.0 kPa T 2 N NPN1 P PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD
PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No. PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.
-100.0~100.0 kPa T 2 X NPN2 Y PNP2 R NPN2+1 T PNP2+1 A1 A S NPN2+1 V PNP2+1 1: A2 B M SI3 P psi2 2 3 kPaMpa B D + M5 M5 1 01 R1/8 N01 NPT1/8 C4H 4mm J (2m) C6H 6mm N7H 1/4 inch C4L 4mm C6L 6mm N7L 1/4 inch -8No.PS-OMU0002CN-D / A ZS-46-A1 38L(2 ) B ZS-46-A2 38L(2 ) ZS-46-B + ZS-46-D ZS-46-5L 5 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch
1 Pressure Control Equipment Regulators Series Application/Characteristics Port size Set pressure (MPa) Option Page Miniature regulator ARJ1020F Direct operated relieving type Back flow function Manifold M5 0.1 to 0.7 14-4-4 1 8 / 14-4-6 Miniature regulator ARJ210 Direct operated relieving type Bracket Pressure gauge M5 to 0.2 to 0.7 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South