70% Stroke mm AS2201F -01-08 AS2200-01 200 100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components
Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V or less IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are
(Option) Foot bracket and manifold mounting possible. 9.9 mm2 SA Maximum frequency (Mechanical operation type) 300 c.p.m. or less Not required (Use turbine oil class 1 ISO VG32, if lubricated.)
SRF ITV +24 V +24 V Output power Output power IC 0 V 0 V Control/Input power Control/Input power ITVH ITVH 24 V +24 V ITVX 4. Each product needs to be powered by one power supply unit.
F9BWV 2-wire Relay, PLC IC circuit No 5 V, 12 V 100 V or less 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Solid state switches marked with are produced upon
Rear Ball valve Test button Flush button Option: V Heavy-duty IDF100F auto drain Check the operation once a day. Option: V IDF125F Option: V IDF150F Enlarged view of part B IDF100F~150F-W 1.3 Name and function of parts 1 5 IDX-OM-M051 Air Dryer 1. Name and Function of Parts Layout of parts on front panel Controller Refer to 3.6 for checking operation.
V MC1 THR TB1,2 SWL PRR PRS1 PRS2 PRS3 PLC HM GFCI EDV IDF100F150F-W 6 6 IDX-OM-Z004 6 6.5 Y Y ,, IDF100F150F-W 6 7 IDX-OM-Z004 6 6.6 () (1) ADH-E400 V 1 -(2) 1 1 ) 1 2 ) Y92S-36/CR2477/ () 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 12 /JEMA 300 A B IDF100F150F-W 6 8
and Z Impact resistance LED Indicators 2 Retaining Screws 2 0 V (US1) 5 5 1 1 No corrosive gas Operating environment 3 FE Power connection (XD2) Push Pull connetor (24 Volt) ON ON Safe input 4 24 V (US1) 24 V (US2) 5 Description Item 7/8" 5-pins Plug (XD1) 7/8" 5-pins Socket (XD2) Power connection (XD1) Push Pull connetor (24 Volt) 4 two-channel or 8 signle-channel Number of inputs 2 1 4
www.stevenengineering.com I 4.17 TUBE FITTINGS: ONE TOUCH FITTINGS KQ, KQ2 SEALANT TYPE P R O D U C T S E L E C T O R U N I V E R S A L M A L E E L B O W : K Q V ( K Q 2 V ) Applicable Thread Model H D1 D2 L1 L2 L3 A M Effective Weight Tube OD R(PT) (Hex) 0rifice (mm2) (g) (mm) Nylon Urethane 4 M5x0.8 KQV04-M5 8 10.4 9.8 20.5 11 18.5 15 16 2.9 2.9 6 4 1/8 KQV04-01S 8 10.4 13.4 22 14.5 26.5
2-M3 x 0.5 depth 3.5 For rail mounting 8 2-M2 x 0.4 depth 3 For magnet mounting 8.5 10.7 6-M5 x 0.8 depth 7 20 20 L (mm) L K J V H S Z M MA W Model 36 40 93 82 58 20 102 40 30 65 MXP16-20B 42 50 119 108 70 30 128 56 46 75 MXP16-30B 14
Color Symbol Color B Black W White R Red BU Blue G Green 15-6-10 1 Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Tubing Series TRB Model Suitable for air and water piping in environments where sparks from spot welders, etc., may be a problem. Double layer design using flame resistant resin (equivalent to UL-94 Standard V-0) for outer layer.
3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.
A or less 24 VDCj 10pA or less 1.5 V or less (10mA: 0.8 V of less) 24 VOCj 1opA or less R e d : O N 1 mS or less solid state switch 3 Wirc lC circuit 28 VDC l5OmA 0.8 V or less 2 V or less (10mA: 0.8 V or less) 24 VDC: 10pA or less 24 VDC] 10llA or less ON: red light emilUng diode ON: red lighl milling diode 1 mS or less ftlo$I{ildl Smies CIA Reed Type Internal Circuit D-A59W.
How To Order,/NVV4Zl Manifold Nvv4zl ::P r =*na, acc$ory F : Mounting brackets 'A .v?
-5 13 3 IDX-OM-W023 13 T IDU15E1-10-T IDU15E1-20/23-T PE 1 3 2 N L N L PE 1 2 3 TB TB MC TDR MC TDR ILS ILS MC TDR MC TDR PTC OLR MC PTC MC OLR CM CM MC C01 C02 MC CR C11 FM1 CR C11 PRS FM1 PRS P C12 FM2 P C12 TDR MC FM2 TDR MC IDU Series 13-5 13 4 IDX-OM-W023 14 V 14 V V IDU8E15E1-23 14-1 1. 1 2 2. 3.
3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.
A or less 24 VDCj 10pA or less 1.5 V or less (10mA: 0.8 V of less) 24 VOCj 1opA or less R e d : O N 1 mS or less solid state switch 3 Wirc lC circuit 28 VDC l5OmA 0.8 V or less 2 V or less (10mA: 0.8 V or less) 24 VDC: 10pA or less 24 VDC] 10llA or less ON: red light emilUng diode ON: red lighl milling diode 1 mS or less ftlo$I{ildl Smies CIA Reed Type Internal Circuit D-A59W.
How To Order,/NVV4Zl Manifold Nvv4zl ::P r =*na, acc$ory F : Mounting brackets 'A .v?
0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.
AW200 1-300 1-400 1 Standard S ecifications Model AW2001 AW3001 AW4001 Port size 1/8,1/4 1/4,3/8 1/4,3/8,1/2 Proof pressure 1.5MPa !15.3kgf/cm2) Max. operating pressure 1.0MPa 110.2kgflcm2) Set pressure range 0.05~0.85MPa 10.51 ~8.7kgflcm2 ) Ambient and fluid temperature -5~60"C (Prevent freezing) Filtration degree 5,t.