Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC100V, Specification: Standard, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0 to 0.9, Driving Type: Linear Motion Poppet
Body Type: O (Manifold), Valve Option: Standard, Voltage: 1 (100VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 6 (3 Position Perfect), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 5 (3 Position Pressure Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Function: 3 Position Exhaust Center, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Port Size: -, Thread: -
Function: 2 Position Single, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Port Size: -, Thread: -
Function: 2 Position Double, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Port Size: -, Thread: -
Function: 3 Position Exhaust Center, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Piping: -, Port Size: -, Thread: -, Option: -
Function: 2 Position Double, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Piping: -, Port Size: -, Thread: -, Option: -
Function: 2 Position Single, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Piping: -, Port Size: -, Thread: -, Option: -
Function: 3 Position Perfect, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Piping: -, Port Size: -, Thread: -, Option: -
Function: 3 Position Pressure Center, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Piping: -, Port Size: -, Thread: -, Option: -
Function: 2 Position Double, Body Option: Base Mounted Non Plug-in, Pilot: Internal Pilot, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Manual Override: -, Port Size: -
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)