. 2-2 2-2-3 . 2-2 2-2-4 . 2-3 2-2-5 . 2-3 2-3 . 2-5 3 / 3-1 . 3-1 3-2 . 3-1 3-3 . 3-2 3-4 . 3-2 3-5 . 3-2 3-6 . 3-2 4 4-1 . 4-1 4-2 . 4-1 4-2-1 () . 4-1 1 4-2-2 . 4-1 4-2-3 . 4-2 5 5-1 . 5-1 6 6-1 . 6-1 6-2 GWP . 6-3 6-3 . 6-4 6-4 . 6-5 6-5 . 6-7 7 C 7-1 . 7-1 7-2 . 7-1 8 K 8-1 . 8-1 8-2 . 8-1 9 L 9-1 . 9-1 9-2 . 9-1 9-3 . 9-2 9-4 . 9-2 10 M 10-1

N.C. 2-3-10 11 Plug-in Unit Series SQ1000 Manifold Specifications Porting specifications (4) 1 station weight (g) (4) (3) 5 station weight (g) Applicable solenoid valve Type of connection (1) Applicable station Port size Base model 1(P), 3(R) 4(A), 2(B) Port location Port size F kit: D-sub connector 1 to 12 stations 420 20 C3 (For 3.2) C4 (For 4) C6 (For 6) M5 (M5 thread) 1 to 12 stations

Example) ARP30K-03BE-1RY Symbol 20 30 40 Body size Description Nil K Without backflow function With backflow function With backflow function + Nil N F Rc NPT G Thread type + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) a Without mounting option With bracket With set nut (For panel mount) Mounting H + Note 1) Nil E G E1 Note 3) Without pressure gauge Square embedded type pressure

external terminals and case Insulation resistance 50M or more (500 VDC Mega) between external terminals and case Vibration resistance 4.9 m/s2 Impact resistance 490 m/s2 to X,Y,Z directions 3 times for each Noise resistance 1000 Vp-p, Pulse width: 1 s, Rise time: 1 ns Weight 140 g (without lead wire) 225 g (without lead wire) Port size 3/8 inch tube 1/2 inch tube 3/4 inch tube Wetted material

Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For

Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For

Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without

How to Order G LG1 05 1 Cable length 05 5m Compatible models G R Y Matsushita Electric Industrial Co., LTD Mitsubishi Electric Corporation Yaskawa Electric Corporation Cable compatibility table Model Manufacturer's No.

Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model Maximum flow capacity l/min (ANR) 1000 200 500 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 0.43 0.68 Weight kg Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less Ambient and fluid temperature 5 to 50C Filtration degree

Thread type Rc NPT G Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model 1000 (35) 200 (7) 500 (17.5) Max. flow capacity l/min (ANR)(SCFM) 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 (2.54) 0.43 (0.95) 0.68 (1.50) Weight kg (lb) Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less (14.5 psi

Port size Body size Thread size Thread type Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.

Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.

AR30 Option Thread type Port size Symbol Nil B E G P Applicable models AR30 to 60 AR30 to 60 AR30 to 60 AR30 to 40 Contents With bracket With square embedded type pressure gauge (with limit indicator) Round pressure gauge (with limit indicator) Panel mount (with set nut) Metric thread (M5) Rc NPT G Nil Note 1) 1 4 02 03 04 06 10 N F 3 8 Note 2) 1 2 3 4 1 Note 1) Bracket assembly is not

04 06 1 4 3 8 Note 2) 1 2 3 4 Note 1) Bracket assembly is not mounted at the time of shipment, but rather packaged together with the filter regulator for shipment.

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: Â

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp.: Â